Coolmay MT-i Series Control Panel Small User Manual

June 11, 2024
Coolmay

Coolmay LOGO MT-i/iQ Series HMI
User Manual

MT-i Series Control Panel Small

Thank you for purchasing Coolmay MT series HMI. This manual provides instructions of product characteristics, general specifications, hardware interface and software settings, etc..Detailed programming, please refer to “Coolmay MT-i/iQ series HMI User Manual”. “Coolmay Programming User Manual”.
HMI main features:

  1. Provides vector galleries and supports self-built gallery
  2. Resistive touch panel with high precision and reliability
  3. Supports any-format static images and GIF animation
  4. Supports all fonts in Windows
  5. 60,000 TFT true color display
  6. Comes with SD card, can store historical data
  7. Support USB flash disk download program and import/export data
  8. Equipped with an RS232 and an RS485 communication port, supporting multiple protocols
  9. Vertical display
  10. Some products can be equipped with network port, WiFi or audio
  11. MT6037i/iQ can be wall mounted

Product Information

Naming rules

  1. Coolmay productseries – MT series HMI

  2. HMI dimension – 6037:3.5″ 6043: 4.3″ 6050:5″ 6070:7″ 6100:10″ 6150:15″

  3. Version andholes – i: basic version (Front panel upper and lower black middle gray)
    iV: basic version vertical;
    iQ: basic version (Front panel unified grey)
    iQV: basic version vertical

  4. Network / WIFI – W: Optional Network port; WIFI: Optional WIFI except 6037 (occupying RS485)

  5. Audio – Y: Audio (optional)

Model| MT6037i/iQ| MT6043i/IQ| MT6050i/iQ| MT6070i/iQ| MT6100i/iQ| MT6150i/iQ
---|---|---|---|---|---|---
Display pane| 33″TFT LCD| 4.3″TFT LCD| 5.01FT LCD| 7.0″TFT LCD| 10.1″TFT LCD| 15.0″ TFT LCD
Resolution| 320240| 480272| 800480| 800480/1024600| 1024600| 1024768
Dimension| 88
8825| 134102’32| 1519636| 21014636| 27519436| 38630040
Cut-outsize| 72
72mm| 12094mm| 14386mm| 192’138mm| 262180mm| 366280mm
Display| 7356mm| 9756mm| 10865mm| 15487mm| 222125mm| 305229mm
Power consumption| 100mA/24V| 150mA/24V| 150mA/24V| 200mA/24V| 280mA/24V| 500mA/24V
Weight| 0.3kg| 0.33kg| 0.33kg| 0.54kg| 0.74| 3.3kg
Brightness| 300cd/m2| 450cd/m2
Power| 12-24VDC ±10%<150mA@24VDC| 15-24vtict Ens
<500mA@24VDC
RAM| 64MB
CPU| 32bit CPU 408MHz
ROM| NOR Flash 16MB (System area) + SD NAND 128MB (D disk)
COM port| RS232, RS485, Network port,WiFi(Occupies RS485 . 6037 doesn’ t support WiF0
Color| 65536 true color
Backlight| LED
Backlight life| 60000 hours
Shell material| engineering plastic ABS+PC
Electric stress test| 500VAC 1 minute
IP level| I P65 (front panel)
Environmental temperature| 0-50°C
Environmental humidity| 20-90%RH
Storage| -20-70°C
Cooling| Natural cooling
Contrast| 400:1
Allow power down| Within 20ms

(Continued)

Item Instructions
USB port Yes
Calendar Yes
Inputvoltage DC24+10%VDC or customized as DC12V/DC5V input
System diagnosis Power effect test
Certificate CE
FCC Conform to FCC Class A
Anti-interference test 1500Vp-p, pulse period 1ps, continue 1s
Quakeproof test 10-25Hz (X,Z direction 2G 30mins)
Insulation resistance More than 10MQ@500VDC
Touch panel 4-wire resistance panel

Mechanical Design

Mounting size

Coolmay MT i Series Control Panel Small - Mounting
Size

Model| Mounting size| Dimension
W’H’D(mm)
---|---|---
A(mm)| B(mm)
MT6037i/iQ| 72| 72| 88’88’25
MT60431/iQ| 120| 94| 134’102’32
MT60501/1Q| 143| 86| 151’196’36
MT6070i/iQ| 192| 138| 210’146’36
MT6100i/iQ| 262| 180| 275’194’36
MT6150i/iQ| 366| 280| 386*300.40

  • More specifications can be customized.

Electrical Design

♦ Product structure
( Note: the front panel of i series products is black at the top and bottom, and gray at the middle; iQ series is uniformly gray; There is no obvious difference between others. The following figure is mainly illustrated by iQ series pictures)Coolmay MT i Series Control Panel Small - Product
Structure

1. PWR :Power indicator
2. LCD
3. Power terminal block
4. Network port(optional)| 5. RS232/RS485
COM:Flash when PLC communicates with HMI
6. USB port
7. DHMI programming port
8.  4 side mounting jack
---|---

Diagram 2 Product Structure

Hardware Interface
MT6037i/iQ

Pin No Description

Definition of R5232 COM
RXD| Receive
TDX| Send
GND| Ground/DC24V-
Definition of RS485 COM
A| 485+
B| 485-
DC24V power supply
24| DC2AVr
GND| Ground/DC24V-

MT6043i/iQ

Coolmay MT i Series Control Panel Small - Hardware Structure
2

Pin No Signal Description

Definition of RS232 COM
1| RXD| Receive
3| TXD| Send
5| GND| Ground
Definition of RS485 COM
1| A| 485+
6| B| 485-

MT6050/iQ

Coolmay MT i Series Control Panel Small - Hardware Structure
3

Pin No Signal Description

Definition of COM1RS232 port
1| RXD| Receive
3| TXD| Send
5| GND| Ground
Definition of RS485 COM port
1| A| 485+
6| B| 485-

MT6070i/iQ

Coolmay MT i Series Control Panel Small - Hardware Structure
4

Pin No Signal Description

Definition of COMI RS232 port
1| RXD| Receive
3| TXD| Send
5| GND| Ground
Definition of RS485 COM port
terminal (Default)| Al| 485+
B1| 485-
Optional and RS232 Cannot be used at the same time| A| 485+
B| 485-

MT6100i/iQ

Coolmay MT i Series Control Panel Small - Hardware Structure
5

Pin No Signal Description

Definition of COM1 RS232 port
2| RXD| Receive
3| TXD| Send
5| GND| Ground
Definition of RS485 COM port
1| A| 485+
6| B| 485-

MT6150i/iQ

Coolmay MT i Series Control Panel Small - Hardware Structure
6

Pin No Signal Description

Definition of COM1 RS232 port
2| RXD| Receive
3| TXD| Send
5| GND| Ground
Definition of RS485 COM| port
terminal (Default)| Al| 485+
B1| 485-
Optional and RS232 Cannot be used at the| A| 485+
B| 485-

Software Parameter settings
Inthe setting of software setting working parameter Link 1, MT-i/iQ series communication port defaults to COM1: RS232; COM2:RS485; f Link 2 s checked, it can communicate with two serial port devices at the same time.
HMI parameter selections:

Model (horizontal) HMI parameters
MT60371/iQ MT6037H[320*240]
MT60431/iQ MT6043H[480*272]
MT60500Q/MT6070i/iQ MT6070H[800*480]
MT6100i/iQ MT6100HA[1024*600]
MT6150i/iQ MT6150HA[1024*768]
MT6043iV/iQV MT6043iQV[272*480]
MT6050iV/IQV/MT6070iV/IQV MT6070iQV[480*800]

Instructions of HMI connecting with all-brand PLCs

Section | COOLMAY CX Series RS232 connection:

  1. MT software settings
  2. Parameter Recommended settings
    :OM protocol CoolMay PLC(3U/30/FX3U
    COM type RS232
    Data bits 7
    Stop bits 1
    Checking bits Even
    Baud rate 9600
  3. MT and COOLMAY CX series PLC RS232 communication cable connection diagram use “CX2N download cable”Coolmay MT i Series Control Panel Small - Brand PLCS 1

RS485 connection:

  1. MT software settings
    Parameter| Recommended settings
    ---|---
    COM protoco| CoolMay PLC(3U/3G)/FX3U
    COM type| RS485
    Data bits| 7
    Stop bits| 1
    Checking bits| Even
    COM rate| 9600
  2. MT and coolmay CX series PLC RS485 communication cable connectionCoolmay MT i Series Control Panel Small - Brand PLCS 2

Notes: MT6037i/iQ communication line configuration:

  1. If communicates with Coolmay FX3GC/FX2NC/DX2N/Mitsubishi PLC, use the same cables as the ones of DX2N(FX2NC) PLC.
  2. If communicates with Coolmay CX3G/CX2N/DCX2N PLC, use the same cables as the ones of CX2N PLC.

Section Il Panasonic FP Series

  1. MT software settings
    Parameter| Recommended settings
    ---|---
    COM protocol| Matsushita FP Series
    COM type| RS232
    Data bits| 8
    Stop bits| 1
    Checking bit| Odd
    COM rate| 9600
  2. MT and Panasonic PLC connections

Coolmay MT i Series Control Panel Small - Brand PLCS 3

Section III Xinjie PLC Series

  1. MT software settings
    Parameter| Recommended settings
    ---|---
    COM protoco| Xinjie PLC Series
    COM type| RS232
    Data bits| 8
    Stop bits| 1
    Checking bits| Even
    COM rate| 19200
  2. MT and Xinjie PLC communication connection diagram

Coolmay MT i Series Control Panel Small - Brand PLCS 4

Section IVOmron C Series

  1. MT software settings
    Parameter| Recommended settings
    ---|---
    PLC type| Omron C/CPM/CP/CS/CJ Series
    COM type| RS232
    Data bits| 7
    Stop bits| 2
    Checking bits| Even
    Baud rate| 9600
    Controller ID| 0
  2. MT(COML)-Omron PLC connections

Coolmay MT i Series Control Panel Small - Brand PLCS 5

Section V Siemens S7-200 Series

  1. MT software settings (change COM1 to RS485)
    Parameter| Recommended settings
    ---|---
    PLC type| Siemens 57-200 Series
    COM type| RS485
    Data bits| 8
    Stop bits| 1
    Checking bits| Even
    Baud rate| 9600
    Controller ID| 2
  2. MT(COML)S7-200 PLC connections

Coolmay MT i Series Control Panel Small - Brand PLCS 6

Section VI Mitsubishi FX Series

  1. MT software settings
    Parameter| Recommended settings
    ---|---
    PLC type| Mitsubishi FX Series
    COM type| RS232
    Data bits| 7
    Stop bits| 1
    Checking bits| Even
    Baud rate| 9600
    Controller ID| 0
  2. MT(COML) FXseries PLC connections
    Use Mitsubishi programming line

Coolmay MT i Series Control Panel Small - Brand PLCS 7

Pin No Signal Description
1 RXD- Receive –
2 RXD+ Receive +
3 GND Ground
4 TXD- External sending-
5 +5V External power supply+5V
6 CCS COM direction control line
7 TXD+ External sending +
8 NC Null

Programming software Coolmay HMI touch screen programming software
Referto “Coolmay MT-i/iQ Series HMI User Manual ” for details

Tips
MT-i/iQ Series HMI User Manual
— Please read carefully the related manuals before using our products, and use this product under the environmental conditions specified in this manual

  1. Power on after confirmed the voltage (24VDC, >18W) and right wiring to avoid damage.
  2. Tighten the screws or the rail while mounting the product to avoid falling off.
  3. Avoid wiring or plug the cable with electricity, or it is easy to cause electric shock or circuit damage. When the product emits odor or abnormal sound, please immediately switch off the power. While processing screw holes or wiring, do not drop the metal chips and wire head into  the ventilation hole of the controller, which may cause product failure and disoperation.
  4. Ground terminals FG on HMI must right gound connection to improve anti-interference ability.
  5. Please do not disassemble the product or modify the wiring. Or it may cause malfunction, malfunction, loss, or fire.
  6. While installing or disassembling the product, ensure to turn off all power. Or it may cause malfunction and breakdown.

Shenzhen Coolmay Technology Co., Ltd
Tel:0755-86950416
86960332
26051858
26400661
Fax:0755-26400661-808
QQ:800053919
Email : 800053919@b.qq.com
Web.: www.coolmay.com
V2022/11

Baidu Cloud Disk QR Code WeChat official account
![Coolmay MT i Series Control Panel Small - QR Code 2](https://manuals.plus

/wp-content/uploads/2023/05/Coolmay-MT-i-Series-Control-Panel-Small-QR- Code-2.jpg)
https://pan.baidu.com/s/1mirysSK| http://weixin.qq.com/r/8kwLE07EBxN4rQpw9xng

Scan the QR code of COOLMAY yun disk, follow the WeChat official account for more technical support

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals