nVent HF0416414 Side Mount Filter Fan Owner’s Manual
- June 27, 2024
- nVent
Table of Contents
nVent HF0416414 Side Mount Filter Fan
Specifications
- Brand: HOFFMAN
- Model: HF04 SIDE-MOUNT FILTER FAN
- Voltage: 115V
- Airflow: 21CFM
- Color: Light Gray
- Catalog Number: HF0416414
Product Information
- The HOFFMAN HF04 SIDE-MOUNT FILTER FAN is designed for easy installation into enclosures with a click-fit design, eliminating the need for tools or screws.
- The grilles can be easily opened with a simple finger flick for quick and convenient filter replacement.
Product Usage Instructions
-
Installation:
To install the HF04 SIDE-MOUNT FILTER FAN, place it in the desired location on the enclosure where ventilation is needed. Use the click-fit design to securely attach the fan without the need for additional tools or screws. -
Filter Replacement:
When it’s time to replace the filter, simply open the grilles by flicking them with your finger. Remove the old filter and replace it with a new one, ensuring proper alignment and fit. -
Maintenance:
Regularly check the filter for any dust or debris buildup. Clean or replace the filter as needed to maintain optimal airflow and cooling performance. -
Safety Precautions:
Always follow nVent’s product instruction sheets and warnings to prevent improper installation or misuse that could lead to product malfunction or injury. Visit www.nvent.com for detailed instructions and guidelines.
FAQ
- Q: Can I use this filter fan in outdoor enclosures?
- A: The HOFFMAN HF04 SIDE-MOUNT FILTER FAN is designed for indoor use only and should not be exposed to outdoor elements.
- Q: How often should I replace the filter?
- A: Filter replacement frequency may vary depending on usage and environmental conditions. Check the filter regularly and replace it when you notice reduced airflow or accumulation of dust.
CATALOG NUMBER
-
HF0416414
-
HF Side-Mount Filter Fans quickly install into the enclosure with a click-fit design; no tools or screws are required. Grilles open with the flick of a finger for easy filter replacement.
FEATURES
- Click-Fit design quickly installs into enclosure wall; no tools or screws required
- Opens with the flick of a finger for easy filter replacement
- Enclosure side wall mounting
- Reverse airflow option on HF13 models available to push/pull air through higher static pressure
- Standard rope gasket provides a proper seal to the enclosure
- Similar cut-out sizes as other filter fan manufacturers
- Terminal block connections
- Optional thermostat available to save energy and extend service life
- The hinged grille remains attached after opening
- Size ranges from 4 inches (102 mm) to 13 inches (325 mm)
- Free airflow from 21 CFM (36 m3/hr.) to 484 CFM (822 m3/hr.)
- Service life hours from 40,000 to 100,000 hours
- Operating temperature range of -4 F/-20 C to 149 F/65 C
PRODUCT ATTRIBUTES
- Article Number: 34192
- Height: 4.42 in
- Width: 4.44 in
- Depth: 3.65 in
- Airflow: 21 ft³/min
- Nominal Voltage: 115 V
- Voltage AC: 100 V
- Max Current: 0.1 A
- Operating Temperature: 14 – 131 °F
- Material: Plastic
- Finish: Smooth Matte
- Color: Light Gray
- Color Code: RAL 7035
- Weight: 1.5 lb
WARNING
nVent products shall be installed and used only as indicated in nVent’s
product instruction sheets and training materials. Instruction sheets are
available at www.nvent.com and from your nVent
customer service representative. Improper installation, misuse,
misapplication, or other failure to completely follow nVent’s instructions and
warnings may cause product malfunction, property damage, serious bodily
injury, and death and/or void your warranty.
© 2024 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. nVent.com
References
- Building a more Sustainable and Electrified World | nVent
- Building a more Sustainable and Electrified World | nVent
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>