Ruijie RG-EST310-V2 Wireless Bridge Reyee User Manual
- June 26, 2024
- RuiJie
Table of Contents
- Ruijie RG-EST310-V2 Wireless Bridge Reyee
- Product Overview
- Device Specification
- Safety Precautions
- Installing the Device
- Verifying Operating Status
- Monitoring and Maintenance
- Troubleshooting
- Appendix A Connectors and Media Description
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ruijie RG-EST310-V2 Wireless Bridge Reyee
Product Overview
RG EST310 V2
The RG EST310 V2 is an 802.11ac wireless bridge launched by Ruijie Reyee.
It provides services such as surveillance video backhaul and wireless remote
transmission in elevators, tower cran es, factories, parks, construction sites
and other scenarios. RG EST310 V2 works in the 5GHz frequency band, supports
two spatial streams and 2 x 2 MIMO, and provides a wireless transmission speed
of up to 867Mbps, which is sufficient to meet the bandwidth requirements of
user services for data links.
Package Contents
Table 1-1 Package Contents
No. | Item | Quantity |
---|---|---|
1 | RG-EST310 V2 (Network Video Recorder Side) | 1 |
2 | RG-EST310 V2 (Camera Side) | 1 |
3 | 24 V/0.6 A Non-Standard PoE Adapter | 2 |
4 | Bracket | 2 |
5 | Hardware Installation and Reference Guide | 1 |
6 | Hose Clamp | 4 |
7 | Wall Anchor and Self-Tapping Screw | 4 |
Note
A normal delivery should contain the above-mentioned items, which may
differ from the actual delivery, depending on purchase contracts. Please check
your goods carefull y against the Package Contents or purchase contract. If
you have any questions or there are any errors, please contact your
distributor.
Figure 1-1 Appearance
Front View
Rear View
Note: The label is located on the back of the device.
Figure 1-2 Port Button
Note
- 12 VDC Port
- 10/100Base T Ethernet Port (PoE capable)
- Reset button
Power Supply
RG-EST310 V2 adopts 12 V 1 A DC or 24 V non-standard PoE power supply. The
device is delivered with a 24 V 0. 5 A power adapter.
Caution
Please do not use a switch or a PoE adapter of another model for power supply.
Otherwise, the device may be damaged.
Table 1-2 LED Description
LED | Status | Description |
---|---|---|
System Status LED | Off | System is not powered on. |
Solid On | Initiation process is complete. | |
Slow Blinking | System is working but there is an alert. | |
Fast Blinking | System is being initialized. | |
Port Status LED | Solid On | The LAN port is not receiving or transmitting data. |
Blinking | The LAN port is receiving or transmitting data. | |
Signal LED | LED 1 is solid on. | -73 dBm< RSSI <-59 dBm |
LED 1 and LED 2
are solid on.
| RSSI > -59 dBm
LED 1, LED 2 and
LED 3 are solid on.
| RSSI > -49 dBm
Off| There is no signal.
Table 1-3 Reset Button Description
Button | Function | Operation |
---|---|---|
Reset | Reboot | Press the button for 2 seconds, and the device will be |
rebooted.
Reset| Press the button for over 5 seconds, and the device will be reset.
No Action| Press the button for 2 to 5 seconds.
Device Specification
Table 1-4 Specification
Radio Design | Single-Frequency Dual-Stream |
---|---|
Transmission Protocol | **** |
802.11 a/n/ac
Operating Frequency| 802.11a/n/ac: 5.150~5.350GHz, 5.470~5.725GHz, 5.725~5.850GHz
United States:802.11a/n/ac:5.180~5.240GHz , 5.745~5.825GHz
Antenna Type| Built-in Directional Antenna, Horizontal 60°, Vertical 30°
Spatial Streams| 2
Max Throughput
| The 5GHz frequency band provides a wireless transmission speed of up to 867Mbps.
Modulation Types
| OFDM: BPSK@6/9Mbps, QPSK@12/18Mbps, 16-QAM@24Mbps,
64-QAM@48/54Mbps
OFDM: BPSK, QPSK,16QAM, 64QAM, 256QAM
Receiver sensitivity
| 802.11a: -89 dBm (6 Mbps), -80 dBm (24 Mbps), -76 dBm (36 Mbps), -71 dBm (54
Mbps)
802.11n: -83 dBm@MCS0, -65 dBm@MCS7, -83 dBm@MCS8, -65 dBm@MCS15
802.11ac: -86 dBm(MCS0), -63 dBm(MCS9)
Max Transmit Power| 400mw (26dBm) (Single-Stream)
Transmit Power Adjustment| ****
1 dBm
Dimensions (L x W x H, without bracket)| ****
147 mm × 76 mm × 37 mm (5.78 in. x 2.99 in. x 1.46 in.)
Weight| 0.35 kg (0.77 lbs.)
Service Ports| One 10/100BASE-T port, supporting 24 V non-standard PoE
power supply
---|---
Management Ports| N/A
Status LED| One system LED, one Ethernet port LED, and three signal LEDs
Power Supply Method| ****
12 VDC and 24 V non-standard PoE power supply
Max Power Consumption| ****
7 W
Bluetooth 5.0| Not supported
Temperature
| Operating Temperature: -30°C to 55°C (-22°F to 131°F)
Storage Temperature: -40°C to 70°C (-40°F to 158°F)
Operating Humidity: 5% to 95% RH (non-condensing)
Storage Humidity: 5% to 95% RH (non-condensing)
Installation Methods| Wall Mounting/Pole Mounting
Certification| CE
MTBF| >400000H
Power Specification
RG-EST310 V2.0 adopts 12 VDC or 24 V/0.6 A non-standard PoE power supply.
Figure 1-3 Non-Standard PoE Adapter
- RJ45 Connector for LAN: 1, 2, 3 and 6 are data cables. 4 and 5 connect the positive post. 7 and 8 connect the negative post.
- RJ45 Connector for P o E: 1, 2, 3 and 6 are data cables. 4 and 5 connect the positive post. 7 and 8 connect the negative post.
Caution
Please do not use a switch or a PoE adapter of another model for power supply.
Otherwise, the device may be damaged.
Heat Dissipation
RG-EST 310 V2 adopts a fanless design. Leave sufficient space around the
device for ventilation
Safety Precautions
Note
- To prevent device damage and physical injury, please read carefully the safety recommendations described in this chapter.
- The following safety suggestions do not cover all possible dangers.
General Safety Precautions
- Do not expose the device to high temperatures, dusts, or harmful gases. Do not install the device in an inflammable or explosive environment. Keep the device away from EMI sources such as large radar stations, radio stations, and substations. Do not subject the device to unstable voltage, vibration, and noises.
- The installation site should be far away from the sea. Keep the device at least 500 meters away from the seaside and do not face it toward the wind from the sea.
- The installation site should be free from water flooding, seepage, dripping, or condensation. The installation site shall be selected according to network planning and features of communication devices, and considerations such as climate, hydrology, geology, earthquake, electric power, and transportation.
Caution
Please follow the correct methods described in the installation guide to
install and remove the device.
- Handling Safety
- Pre-vent the device from being frequently handled
- Cut off all power supplies and unplug all power cords before you move or handle the device.
Electric Safety
Warning
- Improper or incorrect operations may cause a fire or electric shock and other accidents, thus causing severe even fatal damage to human bodies and devices.
- Direct or indirect contact with high voltage or mains power supply via wet objects may cause fatal dangers
- Please observe local regulations and specifications when performing electric operations. Only personnel with relevant qualifications can perform such operations
- Please carefully check for any potential danger in the working area, for example, damp/wet ground or floor.
- Find out the location of the emergency power supply switch in the room before installation. First cut off the power supply in case of an accident.
- Be sure to make a careful check before you shut down the power supply.
- Do not place the device in a damp/wet location. Do not let any liquid enter the device
- Keep the device far away from the grounding or lightning protection devices of the power device.
- Keep the device away from high-power radio stations, radar stations, and high-frequency current devices.
Installation Environment Requirements
To ensure normal operation and prolonged useful life of the device, the
installation site must meet the following requirements.
-
Environment Requirements
- Install the device in a well-ventilated environment. If it is installed in a closed room, make sure there is a good cooling system.
- Make sure the site is sturdy enough to support the device and its accessories.
- Make sure the site has enough space for installing the device and leave sufficient space around the device for ventilation.
-
Ventilation Requirements
For proper ventilation, leave sufficient space around the device. -
Temperature Humidity Requirements
To ensure the normal operation and prolonged service life of the device, maintain an appropriate temperature and humidity in the equipment room. The equipment room with too high or too low temperature and humidity for a long period may damage the device.- In an environment with high relative humidity, the insulating material may have bad insulation or even leak electricity and sometimes the materials may suffer from mechanical performance change and metallic parts may get rusted.
- In an environment with low relative humidity, the insulating strip may dry and shrink, and static electricity is prone to occur and damage the internal circuits of the device. In an environment with high temperatures, the device is subjected to even greater harm, as its performance may degrade significantly and its useful life may be shortened in the case of long-term exposure that expedites the aging process.\
Table 2-1 Temperature and Humidity Requirements
Operating Temperature | Operating Humidity: |
---|---|
-30°C to 55°C (-22°F to 131°F) | 5% to 95% RH (non-condensing) |
Waterproof Requirements
IP65 (Specific Direction)
Anti-interference Requirements
- T ake interference prevention measures for the power supply sytem.
- Keep the device far away from the grounding or lightning protection devices of the power device.
- Keep the device far away from high-power radio stations, radar stations, and high-frequency high current devices.
Tools
Table 2-2 Tools
Common Tools| Phillips screwdriver, hex screwdriver, related copper and
fiber cables, bolts, diagonal pliers, cable ties
---|---
Special Tools
| Anti-static glove, stripping pliers, crimping pliers, crimping pliers for
the crystal head, wire cutter, waterproof tape
Meter| Multimeter
Related devices| ****
PC, screen and keyboard
Note
The installation tools are not included in the scope of delivery and should be
purchased separately.
Installing the Device
Caution : Before installing the device, make sure you have carefully read the requirements described in Chapter 2.
Installation Procedure
Preparing
Carefully plan and arrange the installation location, networking mode, power
supply, and cabling before installation. Confirm the following requirements
before installation: The installation position provides sufficient space for
heat dissipation.
- The installation position meets the temperature and humidity requirements of the device
- The power supply and required current are available in the installation position
- The selected power supply modules meet the system power requirement.
- The network cables have been deployed in the installation position
- The installation site meets all described requirements.
- The device meets the customers’ requirements.
Precautions
It is recommended to mount the device on a pole with a diameter ranging from
35 mm to 89 mm.
Otherwise, you need to prepare a hose clamp of another model. The hose clamp should be at least 2.5 mm thick.
- Please make sure the installation site meets the requirement in Chapter 2.2.1 .
- Please use the 24 V PoE power adapter (Pin 4 and 5 connect to the positive post. Pin 7 and 8 connect to the negative post) delivered with the device or use a power adapter of the same specification.
- The PoE adapter supports power supply over a 100 meter network cable. Before connecting the network cable, make sure that the power supply module is off.
- Make sure that the connector of the power module is fully seated.
Mounting the Device
Caution
- It is recommended to install the device where you can get the optimal coverage.
- The image shown here is for indicative purpose only. The actual product may differ.
Wall Mounting
Figure 3-1 Wall Mounting
Ensure the network cable is connected in advanced.
- Secure the mounting bracket on the wall using wall anchors and screws.
- Install the device to the mounting bracket
Pole Mounting
Figure 3-2 Pole Mounting
- Secure the mounting bracket to the pole by threading two clamps through the mounting bracket.
- Install the device to the mounting bracket.
Connecting Cables
Select a cable (CAT5e or higher) according to the distance between the
wireless bridge and the PSE. Plug one end of the cable into the PoE port of
the PoE adapter and plug the other end into the LAN port of the d device.
Connect the LAN port of the PoE adapter to the server or camera. Plug the PoE
adapter into 220 V power socket Or you can connect the DC port of the device
to the 12 VDC adapter, and connect the LAN port of the device to the server or
camera
Figure 3-3 Connecting Cables
Warning
- Remember to install the bottom cover for waterproof and dustproof purposes.
- Please do not use a switch or a PoE adapter of another model. Otherwise, the device may be damaged.
Verifying Installation
- Checking the Device
- Verify if the external power supply matches the specification.
- Verify that the device has been fastened and will not move or tilt.
- Checking the Power Supply
- Make sure all power cables are properly connected.
- Make sure the device is operational after power is on.
Verifying Operating Status
Setting up Configuration Environment
Power on the device via 12 VDC or 24 V/0.6 A non-standard PoE power supply.
Make sure all power cables are properly connected and meet the safety
requirement.
Checking the Environment before/after Power on
- Before powering on, check the following items:
- Verify that the power supply is properly connected.
- Verify that the input voltage matches the specification.
- After powering on, check the following item
Check the indicator status.
Monitoring and Maintenance
-
Monitoring
When the RG EST31 0 V2 is running, you can monitor the device status by observing the indicator. -
Maintenance
If a hardware error occurs, please contact Ruijie Reyee Technical Support for help.
Troubleshooting
General Troubleshooting Procedure
Appendix A Connectors and Media Description
1000BASE T/100BASE TX/10BASE T
- The 1000BASE T/100BASE TX/10BASE T is a 10/100/1000 Mbps auto-negotiation port that supports auto MDI/MDIX.
- Compliant with IEEE 802.3ab, 1000BA-SE T requires Category 5e 100 ohm UTP or STP (STP is recommended) with a maximum distance of 100 meters (328 feet).
- 1000BASE-T requires all four pairs of wires be connected for data transmission, as shown in Figure 7 1.
Figure 1-1 Figure 7 1 1000BASE T Connection
10BASE-T uses Category 3, 4, 5 100 ohm UTP/STP and 1000BASE T uses Category 5 100 ohm UTP/STP for connections. Both support a maximum length of 100 meters. Figure 7 2 shows100BASE TX/10BASE T pin assignments
Figure 1-2 Figure 7 2 100BASE TX/10BASE T Pin Assignments
Figure 1-3 Figure 7 3 100BASE TX/10BASE T Connection
Copyright
Copyright © 202
4 Ruijie Networks All rights are reserved in this document and this statement . Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Net works is prohibited.
Trademarks including
are owned by Ruijie Networks. All other trademarks or registered trademarks
mentioned in this document are owned by their respective owners.
Disclaimer
The products, services or features you purchase are subject to commercial
contracts and terms. Some or all of the products, services or features
described in this document may not be within the scope of your purchase or
use. Unless otherwise agreed in the contract, Ruijie Networks does not make
any express or implied statement or guarantee for the content of this
document. Due to product version upgrades or other reasons, the content of
this document will be updated from time to time. Ruijie Networks reserves the
right to modify the content of the document without any notice or prompt. This
manual is for reference only. Ruijie Networks endeavours to ensure content
accuracy and will not shoulder any responsibility for losses and damages
caused due to content omissions, inaccuracies or errors.
Intended Audience
This document is intended for:
- Network engineers
- Technical support and servicing engineers
- Network administrators
Technical Support
- The official website of Ruijie Reyee: is https://www.ruijienetworks.com/products/reyee
- Technical Support Website: https://www.ruijienetworks.com/support
- Case Portal: https://www.ruijienetworks.com/support/caseportal
- Community: https://community.ruijienetworks.com
- Technical Support Email : servicerj@ruijienetworks.com
- Online Robot/Live Chat: https://ruijienetworks.com/rita
Conventions
-
Signs
The signs used in this document are described as below: Danger An alert that calls attention to safety operation instructions that if not understood or followed when operating the device can result in physical injury. -
Warning
An alert that calls attention to important rules and information that if not understood or followed can result in data loss or equipment damage. -
Caution
An alert that calls attention to essential information that if not understood or followed can result in function failure or performance degradation. -
Note
An alert that contains additional or supplementary information that if not understood or followed will not lead to serious consequences. -
Specification
An alert that contains a description of product or version support.
Note
This manual provides the device installation steps, hardware troubleshooting,
module technical specifications, and specifications and usage guidelines for
cables and connectors. It is intended for the users wh o have some experience
in installing and maintaining network hardware. At the same time, it is
assumed that the users are already familiar with the related terms and
concepts.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>