Product Information
Specifications
- Model: KVFS – Vertical Fan Coil, Slant Top / KVFF – Vertical Fan Coil, Flat Top / KVFH – Vertical Fan Coil, Concealed Floor
- Series: KVF Series
- Type: Vertical | Standard
Product Description
Designed for Maximum Flexibility:
The vertical floor fan coil units offer a wide range of standard options to
meet the HVAC system designer’s needs. Models KVFF and KVFS provide additional
height and width dimensions to accommodate architectural requirements.
Options include:
- Single-wall stainless steel drain pan
- MERV 8 and MERV 13 filters
- Electric heat with single-point power connection
All electric heat units are ETL listed as an assembly and carry the cETL label. Units comply with AHRI Standard 440 for testing and rating fan coil units.
Construction Features:
- End Pockets: 8 accessible end pockets for optional factory piping packages and controls. Removable end panels for greater access.
- Fan Deck: Easily removable fan/drain pan assembly for service access to motors and blowers.
- Drain Pan: Sloped insulated primary drain pan available in stainless steel construction. Removable for cleaning.
- Coil Options: Allow for various chilled water or DX cooling coils, and hot water heating coils.
Optimum Building Performance:
Concealed vertical floor fan coil chassis made from galvanized steel
surpasses ASTM corrosion tests. Exposed cabinet models feature powder-coated
galvannealed steel. All units are cETL listed and labelled, ensuring safety
and quality.
Product Usage Instructions
- Ensure proper electrical connections before use.
- Check and replace filters regularly for optimal performance.
- Maintain cleanliness of the drain pan to prevent blockages.
- If servicing the fan/motor, follow manufacturer guidelines for removal and reinstallation.
FAQ
-
Q: How often should filters be replaced?
A: Filters should typically be replaced every 3-6 months depending on usage and environmental factors. Inspect them regularly for any signs of dirt buildup. -
Q: Can the coil options be changed after installation?
A: It is recommended to consult a professional technician for any changes to coil options post-installation to ensure compatibility and proper functioning of the unit.
INTRODUCTION
- Krueger vertical floor-mounted fan coil units are designed to maximize flexibility of selection and installation.
- The units are also designed to exceed the stringent quality standards of the institutional market while remaining cost-competitive in the light commercial segment of the market.
- Krueger vertical fan coil units set new standards for quality, flexibility, and competitive pricing.
MODEL
- KVFS – Vertical Fan Coil, Slant Top
- KVFF – Vertical Fan Coil, Flat Top
- KVFH – Vertical Fan Coil, Concealed Floor
PRODUCT DESCRIPTION
DESIGNED FOR MAXIMUM FLEXIBILITY
- The extensive variety of standard options available on vertical floor fan coil units is where you find the versatility to fit any HVAC system designer’s needs. Models KVFF and KVFS allow for additional height and width dimensions to meet architectural demand.
- Options include single wall stainless steel drain pan; MERV 8 and MERV 13 filters; and electric heat with single point power connection. All electric heat units are listed with ETL as an assembly and carry the cETL label.
- All units comply with the latest edition of AHRI Standard 440 for testing and rating fan coil units, are certified, and display the AHRI symbol.
- High-efficiency motors, fan relays, disconnects and fusing mean easier coordination between mechanical and electrical trades.
- Coil options allow for 3 or 4-row chilled water or DX cooling coils, and 1 or 2-row hot water heating coils.
- Silent solid-state relays are available for fan and electric heat control in sound-sensitive environments
OPTIMUM BUILDING PERFORMANCE
- Concealed vertical floor fan coil chassis are built from galvanized steel. This metal surpasses the ASTM 125-hour salt spray test for corrosion and rust. Exposed cabinet models are powder-coated galvannealed steel.
- All units, with or without electric heat, are cETL listed and labelled. All wiring complies with NEC, assuring safety and quality for the owner.
- Floor-mounted cabinet models feature finned tubular heating elements in the reheat position, protecting room occupants from electrical shock.
- Vertical floor fan coil units have a removable fan/drain pan assembly. The entire fan assembly can be easily removed from the unit and serviced on a workbench.
- Filters are easily replaceable from the return air-toe space without the need for tools or removal of the front panel.
CONVENIENT INSTALLATION
- All vertical floor fan coils are shipped completely assembled, reducing field installation time and labour. All units are thoroughly inspected and tested before shipment, eliminating potential problems at startup. Motor wiring is brought to a junction box on the inside of the unit end pocket, reducing electrical hook-up time.
- Factory-furnished valve packages assure proper fit, operation and performance.
CONSTRUCTION FEATURES
- End Pockets: The 8” end pockets allow for accessibility and service of optional factory piping packages and controls. End panels are removable to allow for even greater access.
- Fan Deck: The fan/drain pan assembly is easily removable for service access to motors and blowers at, or away from, the unit.
- Fan Deck Removal: KVF units allow for a single technician to service the fan/motor by keeping the fan deck to less than 44”. Motors are supplied with quick connectors to allow electrical service without the need for tools.
- Drain Pan: The sloped insulated primary drain pan is available in stainless steel construction. The standard drain pan is externally insulated, single-wall galvanized steel. The KVF Series fan/drain pan assembly is easily removable for cleaning.
- Coils: All fan coils are available in 2 or 4-pipe configurations. The heating coil is standard in the reheat position. Heating and cooling coils are available with the same or opposite end connections. Access for cleaning on the entering air side is available when the drain pan is removed. Coils are removable for service.
- Filter: The filter is easily replaceable through the return air toe space without requiring the removal of the front panel.
- Powder Coated Painted Surface: Exposed cabinet Models KVFF and KVFS, as well as supply and return air grilles and the KVFH wall recessing panel, feature a powder coat finish that resists scuffing, scratching, fading, and fingerprints.
- Control Enclosure: The KVF control enclosure provides adequate space for the unit controller and fan coil relay. The fan coil relay is designed to limit diagnostic problems while allowing for multi-voltage fan power input. The board is designed for factory-installed, color-coded, plug-and-play connections designed to ensure accurate wiring.
- Piping Packages: Factory-installed piping packages come equipped with components specific to the project. Actuators ship with colour-coded plug-and-play connections for quick, accurate installations
- Lid Removal: The top panel is removable from the fan coil without the need to disconnect piping or electrical wires.
STANDARD FEATURES
Construction
All Units
- AHRI 440 certified and labeled
- Galvanized steel construction
- Insulation: elastomeric closed cell foam
- Integral filter rack with 1” throwaway filter
Concealed Units
- To supply with duct collar
Exposed Units
- Top stamped louvre supply grille
- Durable powder coat paint
- End pockets with removable panels
- 20 gauge exterior panel construction
- Flat top
- Slant top
Coils
- Cooling – 3 or 4-row chilled water or DX, heat pump compatible
- Heating – 1 or 2-row hot water – reheat position
- 1/2” O.D. seamless copper tubes
- 0.016” tube wall thickness
- High-efficiency aluminum fin surface for optimizing heat transfer, pressure drop and carryover
- Left or right-hand, same or opposite-end connections
- Removable for service
- Manual air vents
Drain Pans
- Single wall, galvanized steel, externally insulated – fire retardant and antimicrobial
- Positively sloped to drain connection
- 3/4” M.P.T. auxiliary drain pan connection
- Double wall plastic auxiliary drip pan
Fan Assemblies
- Forward curved, DWDI centrifugal type
- 115-volt, 1-phase, 3-speed PSC motors
- Quick disconnect motor connections
- Removable for service
Electrical
- cETL listed for safety compliance
- Electrical junction box for field wiring terminations
- Terminal block for field connections
Electric Heat
- Finned tubular elements on all floor-mounted units protect against electrical shock
- ETL listed as an assembly for safety compliance
- Integral electric heat assembly with removable elements for easy service
- Automatic reset primary and backup secondary thermal limits
- Single-point power connection
OPTIONAL FEATURES
Construction
All Units
- Manual and motorized outside air dampers
- Spare 1” throwaway filters and 1” pleated filters (MERV 8 & 13)
- Wall boxes
- Levelling legs
Concealed Units
- Wall recessing panels
Exposed Units
- Linear bar discharge grille, powder-coated
- 16 gauge front panel
- Return air louvre grille
- 2” – 8” flashbacks
- Extended end pockets
- Tamper-proof fasteners
Coils
- Automatic air vents
- Stainless steel coil casings
- 3/8″ O.D. seamless copper tubes (0.012″ tube wall thickness)
Drain Pans
- Stainless steel construction with external insulation
- Double wall plastic auxiliary drain pan – extended length
- Stainless steel auxiliary drain pan – extended length
Fan Assemblies
- 115, 208-230, 220 and 277 volt, 1-phase EC motors
Electrical
- SCR fan speed controller
- Fan relay packages
- Silent solid-state fan relays
- Toggle disconnect switch
- Condensate overflow switch (auxiliary drain pan)
- 2-10VDC, 3-speed fixed or adjustable ECM control
- Unit and remote-mounted 3-speed fan switches
Electric Heat
- Door interlocking disconnect switches
- Main fusing
- Silent relay/contactors
Piping Packages
- Factory assembled – shipped loose for field installation
- 1/2” and 3/4”, 2 and 3-way normally closed, 2-position electric motorized valves
- Isolation ball valves with memory stop
- 4-pipe with 3-way valve
- Fixed and adjustable flow control devices
- Unions and P/T ports
- Modulating control valves
- High pressure close-off actuators (1/2” = 50 PSIG; 3/4” = 25 PSIG)
Thermostats
- Digital display; programmable; auto/manual changeover
- Unit and remote mounted with integral 3-speed fan switch
- 2 and 4-pipe control sequences
CONSTRUCTION HIGHLIGHTS
END POCKETS:
The 8″ end pockets allow for accessibility and service of optional factory
piping packages and controls. End panels are removable to allow for even
greater access.
COILS:
All fan coils are available in 2-pipe or 4-pipe configurations. The heating
coil is standard in the reheat position. Heating and cooling coils are
available with the same or opposite end connections. Access for cleaning on
the entering air side is available when the drain pan is removed. Coils are
removable for service.
FAN DECK:
The fan/drain pan assembly is easily removable for service access to motors
and blowers at, or away from, the unit.
FILTER:
The filter is easily replaceable through the return air toe space without
requiring the removal of the front panel.
DRAIN PAN:
The sloped insulated primary drain pan is available in stainless steel
construction. The standard drain pan is externally insulated, single-wall
galvanized steel. The KVF Series fan/drain pan assembly is easily removable
for cleaning.
POWDER COATED PAINTED SURFACE:
Exposed cabinet Models KVFF and KVFS, as well as supply and return air grilles
and the KVFH wall recessing panel, feature a powder coat finish that resists
scuffing, scratching, fading, and fingerprints.
CONTROL ENCLOSURE:
The KVF control enclosure provides adequate space for the unit controller and
fan coil relay. The fan coil relay is designed to limit diagnostic problems
while allowing for multi-voltage fan power input. The board is designed for
factory-installed, color-coded, plug-and-play connections designed to ensure
accurate wiring.
PIPING PACKAGES:
Factory-installed piping packages come equipped with components specific to
the project. Actuators ship with colour-coded plug-and-play connections for
quick, accurate installations.
FAN DECK REMOVAL:
KVF units allow for a single technician to service the fan/motor by keeping
the fan deck to less than 44″. Motors are supplied with quick connectors to
allow electrical service without the need for tools.
LID REMOVAL:
The top panel is removable from the fan coil without the need to disconnect
piping or electrical wires.
FEATURES DETAIL
© Copyright Krueger 2023.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>