Table of Contents
- ELATION SEVEN PAR 7IP Seven Color Par Light
- Product Information
- Product Usage Instructions
- DOCUMENT VERSION
- GENERAL INFORMATION
- LIMITED WARRANTY (USA ONLY)
- SAFETY GUIDELINES
- MAINTENANCE GUIDELINES
- FIXTURE OVERVIEW
- INSTALLATION INSTRUCTIONS
- LCD CONTROL PANEL LOCKOUT
- COL OR MACROS CHART
- TECHNICAL SPECIFICATIONS
- FCC STATEMENT
- DIMENSIONAL DRAWINGS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELATION SEVEN PAR 7IP Seven Color Par Light
Specifications
- Brand: Elation Professional
- Model: SEVEN PAR 7IPTM
- Power: N/A
- Weight: N/A
- Dimensions: N/A
- DMX Channel Modes: RGB 3CH, RGBSeven 3CH, 8bit 7CH, 16bit 14CH, Master 15CH, HSI 4CH, HSI Mast 10CH
Product Information
General Information
This fixture is designed to perform reliably for years when following the
instructions in this manual. Please read and understand all the instructions
and guidelines carefully before
operating this unit. The manual contains important information regarding
safety, installation, use, and maintenance.
Unpacking
When unpacking the product, ensure all components are present and in good
condition. Refer to the manual for proper setup and installation instructions.
Customer Support
For setup help and operation questions, contact Elation Professional
customer support via phone or visit their website. For service-related issues,
reach out to Elation Professional
directly.
Warranty Registration/Returns
For limited warranty information and registration, refer to the warranty
section in the manual.
Product Usage Instructions
Safety Guidelines
It is essential to properly ground the fixture as it falls under Protection
Class 1. Do not attempt any repairs yourself as it may void the manufacturer’s
warranty. Any damages resulting from modifications or disregard of safety
instructions void the warranty.
Maintenance Guidelines
Follow the maintenance guidelines outlined in the manual to ensure optimal
performance and longevity of the product. Regular maintenance can prolong the
life of the fixture.
Installation Guidelines
Refer to the installation section in the manual for detailed instructions
on how to set up the fixture correctly. Ensure proper rigging and assembly to
prevent accidents or damage.
System Menu and DMX Channel Functions
The manual provides information on the system menu, DMX channel functions,
and values. Familiarize yourself with these settings to operate the product
effectively.
FAQ
-
Q: Can I repair the fixture myself if an issue arises?
A: No, attempting repairs yourself may void the warranty. Contact Elation Professional for service-related concerns. -
Q: Where can I find the latest version of the user manual?
A: Check www.elationlighting.com for the most up-to-date revision of the manual before installation or programming. -
Q: How do I contact customer support for assistance?
A: You can reach Elation Professional customer support via phone during their operating hours or by email.
©2024 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. ELATION PROFESSIONAL logo and identifying product names and numbers
herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed
includes all forms and matters of copyrightable materials and information now
allowed by statutory or judicial law or hereinafter granted. Product names
used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All non-ELATION brands and
product names are trademarks or registered trademarks of their respective
companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
info@elationlighting.com Elation
Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+ 31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu Elation Professional
Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+ 52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online.
Please check www.elationlighting.com for the
latest revision/update of this manual, before beginning installation and/or
programming.
**Date| ****Document Version| ****Software Version ≥|
DMX
Channel Modes| ****Notes
---|---|---|---|---
** 05/11/18| 1| 1.04| CH:03 RGB, CH:07 8Bit, CH:14 16Bit, CH:15
Master, CH:04 H S I, CH:10 H S I+| Initial release.
05/14/18| 1.2| N/C| NO CHANGE| Updated release.
06/19/18| 1.4| ** 1.05| RGB 3CH, RGBSeven 3CH, 8bit 7CH, 16bit
14CH, Master 15CH** , HSI 4CH, HSI Mast 10CH| Updated System Menu / DMX
modes.
09/15/20| 1.6| 1.08| NO CHANGE| Updated primary/secondary
04/24/24| 1.8| N/C| No Change| Added Color Macros Table, Updated FCC Statement
GENERAL INFORMATION
INTRODUCTION
This fixture has been designed to perform reliably for years when the
information in this manual are followed. Please read and understand all the
instructions and guidelines carefully and thoroughly before operating this
unit. This manual contains important information regarding safety,
installation, use, and maintenance.
UNPACKING
Each fixture has been thoroughly tested and shipped in perfect operating
condition. Carefully check the outer shipping carton for signs of any damage
that may have occurred during shipping. If the outer carton appears to be
damaged, carefully inspect the fixture for damage and be sure all included
accessories have arrived intact. In the event damage has been found and/or
parts are missing, please contact our customer support team for further
instructions. Please do NOT return this fixture to your dealer without first
contacting customer support at the number listed below. Please do NOT discard
the outer shipping carton in the trash. Please recycle whenever possible.
CUSTOMER SUPPORT
Elation Professional provides a customer support line to provide set up help
and answer any set up or operation questions. You may also visit us on the web
at www.elationlighting.com for any comments
or suggestions. For service related issue please contact Elation Professional.
ELATION SERVICE USA – Monday – Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax:
323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION / RETURNS
Please register online: http://www.elationlighting.com/Login.aspx to
validate your purchase. All returned service items whether under warranty or
not, must be freight pre-paid and accompany a return authorization (R.A.)
number. The R.A. number must be clearly written on the outside of the return
package. A brief description of the problem as well as the R.A. number must
also be written down on a piece of paper and included in the shipping
container. If the unit is under warranty, you must provide a copy of your
proof of purchase invoice. Items returned without a R.A. number clearly marked
on the outside of the package will be refused and returned at customer’s
expense. You may obtain a R.A. number by contacting customer support.
LIMITED WARRANTY (USA ONLY)
- Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
- For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
- This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
- This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
- Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
- No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
- This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee a
smooth operation, it is important to follow all instructions and guidelines in
this manual. Elation Professional is not responsible for injury and/or damages
resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel
should perform installation of this fixture and only the original rigging
parts (omega brackets) included with this fixture should be used for
installation. Any modifications to the fixture and/or the included mounting
hardware will void the original manufactures warranty and increase the risk of
damage and/or personal injury.
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE
DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE
MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR
REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE
MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC
GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION
AND/OR ELECTRICAL SHORT CIRCUIT.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK – MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
SAFETY GUIDE LINES
CAUTION
HIGH INITENSITY – UV ULTRAVIOLET LIGHT
AVOID DIRECT EYE & SKIN EXPOSURE.
WEAR PROPER EYE & SKIN PROTECTION.
SEE MANUAL FOR SAFETY INSTRUCTIONS.
RISK GROUP 3 – RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS
HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV LED. WEAR
PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE TO UV LED.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING UV PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK
DIRECTLY INTO THE UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL
INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS
SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR
INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED
TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating
fixture.
DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if
any of the power cord connectors are damaged and do not insert into the
fixture securely with ease. NEVER force a power cord connector into the
fixture. If the power cord or any of its connectors are damaged, replace it
immediately with a new one of similar power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper
cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end,
never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit
from the interior of the fixture. This is a normal process and is caused by
excess paint in the interior of the casing burning off from the heat
associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for
many years. ONLY use the original packaging and materials to transport the
fixture in for service.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light
output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
environments can cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to
avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended
life. There are no user serviceable parts inside this fixture, please refer
all other service issues to an authorized Elation service technician. Should
you need any spare parts, please order genuine parts from your local Elation
dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose
screws may fall out during normal operation resulting in damage or injury as
larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing
could allow for dust to enter into the fixture. Damaged rigging points or
unsecured rigging could cause the fixture to fall and seriously injure a
person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. NEVER remove the ground prong from the power cable.
FIXTURE OVERVIEW
- OLED Menu Control Display
- Mode/Up/Down/Enter Buttons
- IP Rated 5pin DMX IN
- IP65 Power IN
- IP65 Power OUT
- IP Rated 5pin DMX OUT
- Air Valve
BOX CONTENTS
- Gel Frame
- Gel Frame Holder / Screw Kit
- IP65 Power Cable
INSTALLATION INSTRUCTIONS
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
environments and has been designed with an enclosure that effectively protects
the ingress (entry) of external foreign objects such as dust and water. The
International Protection (IP) rating system is commonly expressed as “IP”
(Ingress Protection) followed by two numbers (i.e. IP65) where the numbers
define the degree of protection. The first digit (Foreign Bodies Protection)
indicates the extent of protection against particles entering the fixture and
the second digit (Water Protection) indicates the extent of protection against
water entering the fixture. An IP65 rated lighting fixture is one, which has
been designed and tested to protect against the ingress of dust (6) and low-
pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
Please note although this fixture is IP rated, the fixture is NOT suitable for
marine and/or coastal environment installations. Installing this fixture in a
marine and/or coastal environment may cause corrosion and/or excessive wear to
the interior and/or exterior components of the fixture. Damages and/or
performance issues resulting from installation in a marine and/or coastal
environment will void the manufactures warranty and will NOT be subject to any
warranty claims and/or repairs.
OPTIONAL CORROSION-RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please contact Elation Professional for more details.
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A NON-CONDUCTIVE
DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER
INGRESS/CONDENSATION AND/OR CORROSION.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION
OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK
SILK SCREEN FOR MAX AMPS.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country
commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures
for custom matrix designs to any metal truss/structure or placing the
fixture(s) on any surface, a professional equipment installer MUST be
consulted to determine if the metal truss/structure or surface is properly
certified to safely hold the combined weight of the fixture(s), clamps,
cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas,
or away from areas were unauthorized personnel might reach the fixture by
hand.
NEVER stand directly below the fixture(s) when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety
attachment, such as an appropriately rated safety cable that can hold 10 times
the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool down before serving.
****TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING
FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.
GEL FRAME AND BARN DOORS INSTALLATION
The included Gel Frame Holder / Screw Kit must be attached to the fixture in
order to attach the included Gel Frame and optional Barn Doors (sold
separately).
The spring-loaded Gel Frame Holder lock secures both the Gel Frame and Barn
Doors.
-
Attach Gel Frame Holder / Screw Kit to fixture, tightening each screw by hand.
DO NOT OVER TIGHTEN SCREWS!
Insert Gel Frame into Gel Frame Holder by pushing the lock back and sliding into place. -
Insert Barn Doors into Gel Frame Holder by pushing lock back and sliding into place. Gel Frame (even if not used) must be in Gel Frame Holder when using the Barn Doors.
-
Secure Gel Frame Holder lock to secure both Gel Frame and Barn Doors to fixture.
-
Position Barn Doors as desired.
CLAMP MOUNTING
This fixture includes an adjustable dual mounting yoke and safety cable
rigging point attached to the fixture (see the illustration below). When
mounting this fixture to truss, be sure to secure an appropriately rated clamp
(not included) to the yoke using an M10 screw and attach a SAFETY CABLE to the
safety cable rigging point.
OVERHEAD RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and
periodic safety inspection of all installation material and the fixture. If
you lack these qualifications, do not attempt the installation yourself.
Improper installation can result in bodily injury and property damage.
POWER LINKING
****USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS
FIXTURE. CHECK SILK SCREEN FOR AMX AMPS.
SYSTEM MENU
The fixture includes an easy to navigate system menu. The OLED control panel
display (see image below) located on the back of the fixture, provides access
to the main system menu and is where all necessary system adjustments are made
to the fixture. During normal operation, pressing MENU button once will access
the fixture’s main menu. Once in the main menu you can navigate through the
different functions and access the sub-menus with the UP and DOWN buttons.
Once you reach a field that requires adjusting, press the ENTER button to
activate that field and use the UP and DOWN buttons to adjust the field.
Pressing the ENTER button once more will confirm your setting. You may exit
the main menu at any time without making any adjustments by pressing the MENU
button.
LCD CONTROL PANEL LOCKOUT
When Display menu is set to ON, the LCD display backlight will turn OFF after
30 seconds and the Control Panel will lock and the display will show
LOCKED.
Press and hold the MODE button for 5 seconds to unlock.
When Display menu is set to ON1, the LCD display backlight will turn OFF after
30 seconds and the Control Panel will lock and the display will show
LOCKED.
To unlock the Control Panel follow these steps:
- When locked, the display will show: LOCKED*****
- Press UP, then the display will change to: LOCKED*** (one disappears)
- Press DOWN, then the display will change to: LOCKED** (two disappear)
- Press UP, then the display will change to: LOCKED* (three disappear)
- Press DOWN, then the display will change to: LOCKED (4 disappear)
- Press ENTER, then the display will change to LOCKED and then become unlocked.
S Y S T E M M E N U
Supports Software Versions: ≥ 1.05
Features are subject to change without any prior written notice.
MENU| SUB MENU| OPTIONS / VALUES (Default Settings in
BOLD)| DESCRIPTION
Address| Set ADDR| 001 ~ xxx| DMX Address Setting
Mode| | RGB 3CH, RGBSeven 3CH, 8bit 7CH, 16bit 14CH, Master 15CH , HSI
4CH, HSI Mast 10CH| DMX Channel / User Mode
Function| No DMX| Hold / Black / Program| Function If NO DMX Detected
LCD.Set| Display| On / Off| LCD Backlight Shut Off Time
Key Lock| On / On1 / Off| LCD Buttons Key Lock (see page 13 for details)
Flash| On / Off| Display flashes when NO DMX
Inverse| On / Off| Flips LCD Display 180 Degrees
Temp. C/F| F / C| Temperature Switch Between F˚/ C˚
DimCurve| Standard , Stage, TV, Architec, Theatre, Stage2| Set Dimmer
Curve Mode
Disp.Set| ADDR, Disp.CH| Select Default Display
Gamma| 2.0 , 2.2, 2.4, 2.8| Set Gamma Brightness
Frequen| 900Hz , 1000Hz, 1100Hz, 1200Hz, 1300Hz, 1400Hz, 1500Hz,
2500Hz, 4000Hz, 5000Hz, 10kHz, 15kHz, 20kHz, 25kHz| Set LED Refresh Frequency
Defaults| Reset? / Cancel| Restore Factory Settings
Program| Speed| 1 -99| Set Program Speed from Slow (1) to Fast (99)
Color| STATIC| Strobe 000- 255 R , G, B, RG, GB, RB, RGB, BLACK|
Select Static Color and Shutter/Strobe Value
CHANG15| Strobe 000- 255| Select 15 Color Program + Shutter/Strobe Value
CHANG30| Strobe 000- 255| Select 30 Color Program + Shutter/Strobe Value
FADE| Strobe 000- 255| Select Fade Color Program + Shutter/Strobe Value
Macros| 0 -63| Select Color Macro
Secondry| OFF , SECONDRY| Enable Secondary Mode
Info| TimeInfo| Current| XXXX (Hours)| Fixture Run Time from Power ON
Total| XXXX (Hours)| Fixture Total Run Time
Last| XXXX (Hours)| Fixture Last Run Time
PassWord| PIN= 050| Enter PIN to Access Clear Last. Menu
Clear| Off / On| Clear Fixture Last Run Time
TempInfo| XXX F° / C°| Temperature in Fixture Head
ModelInf| SEVEN PAR 7IP| Display Model Name
SoftWare| ≥ V1.05| Software Versions (greater than or equal to)
Err.Info| Error Record 1 ~ Error Record 10| Display 10 Recent Error Messages
Supports Software Versions: ≥ 1.05
Features are subject to change without any prior written notice.
MENU| SUB MENU| OPTIONS / VALUES (Default Settings in
BOLD)| DESCRIPTION
Manual| | Strobe| 000 – 255| Set DMX Values Manually
Dimmer| 000 – 255
Red| 000 – 255
Green| 000 – 255
Blue| 000 – 255
Amber| 000 – 255
White| 000 – 255
Lime| 000 – 255
UV| 000 – 255
Calibrat| Password| 050| Enter Password to Access Calibration Menu
NOTE: ONLY QUALIFIED TECHNICIANS SHOULD PERFORM
THIS FUNCTION!
DMX CHANNEL F UNCT I ONS AND VAL UES
ELATION SEVEN PAR 7IP | DMX Channel Values / Functions (15 DMX Channels)
Supports Software Versions: ≥ 1.05
Features subject to change without any prior written notice.
NOTE: ALL SEVEN COLORS USED IN RGBSeven 3CH Mode
MODE / CHANNEL| **VALUE| ****FUNCTION
RGB 3CH| RGBSeven 3CH| 8Bit 7CH| 16Bit 14CH|
Master 15CH| HSI 4CH| HIS Mast 10CH
| | | | ** 1| | 1| | SHUTTER / STROBE
0-31| LED OFF
32-63| LED ON
64-95| Strobe Effect SLOW to FAST
96-127| LED ON
128-159| Strobe Pulse Effect In Sequences SLOW to FAST
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | | | 2| 1| 2| | MASTER DIMMER / INTENSITY
0-255| 0-100%
| | | | 3| 2| 3| | MASTER DIMMER / INTENSITY FINE
0-255| 0-100%
| | | | 4| | 4| | DIMMING MODES
0-20| STANDARD
21-40| STAGE
41-60| TV
61-80| ARCHITECTURAL
81-100| THEATER
101-120| STAGE 2
121-255| DEFAULT TO UNIT SETTING
| | | | **** 5| | **** 5| | PROGRAM MACROS
0-19| NO FUNCTION
20-39| PROGRAM 01
40-59| PROGRAM 02
60-79| PROGRAM 03
80-99| PROGRAM 04
100-119| PROGRAM 05
120-139| PROGRAM 06
140-159| PROGRAM 07
160-179| PROGRAM 08
180-199| PROGRAM 09
200-219| PROGRAM 10
220-239| PROGRAM 11
240-255| PROGRAM 12
| | | | 6| | 6| | PROGRAM MACRO SPEED
0-255| Program Macro SPEED SLOW to FAST
| | | | 7| | 7| | PROGRAM MACRO FADE
0-255| Program Macro FADE SLOW to FAST
Supports Software Versions: ≥ 1.05
Features subject to change without any prior written notice.
NOTE: ALL SEVEN COLORS USED IN RGBSeven 3CH Mode
MODE / CHANNEL| **VALUE| ****FUNCTION
RGB 3CH| RGBSeven 3CH| 8Bit 7CH| 16Bit 14CH|
Master 15CH| HSI 4CH| HIS**
Mast 10CH
| | | | 8| | 8| | COLOR MACROS
1-4| Color Macro 01
5-8| Color Macro 02
9-12| Color Macro 03
13-16| Color Macro 04
17-20| Color Macro 05
21-24| Color Macro 06
25-28| Color Macro 07
29-32| Color Macro 08
33-36| Color Macro 09
37-40| Color Macro 10
41-44| Color Macro 11
45-48| Color Macro 12
49-52| Color Macro 13
53-56| Color Macro 14
57-60| Color Macro 15
61-64| Color Macro 16
65-68| Color Macro 17
69-72| Color Macro 18
73-76| Color Macro 19
77-80| Color Macro 20
81-84| Color Macro 21
85-88| Color Macro 22
89-92| Color Macro 23
93-96| Color Macro 24
97-100| Color Macro 25
101-104| Color Macro 26
105-108| Color Macro 27
109-112| Color Macro 28
113-116| Color Macro 29
117-120| Color Macro 30
121-124| Color Macro 31
125-128| Color Macro 32
**Supports Software Versions: ≥ 1.05**
Features subject to change without any prior written notice.
NOTE: ALL SEVEN COLORS USED IN RGBSeven 3CH Mode
MODE / CHANNEL| **VALUE| ****FUNCTION
RGB 3CH| RGBSeven 3CH| 8Bit 7CH| 16Bit 14CH|
Master 15CH| HSI 4CH| HIS Mast 10CH
| | | | ** 8| | **** 8| 129-132| Color Macro 33
133-136| Color Macro 34
137-140| Color Macro 35
141-144| Color Macro 36
145-148| Color Macro 37
149-152| Color Macro 38
153-156| Color Macro 39
157-160| Color Macro 40
161-164| Color Macro 41
165-168| Color Macro 42
169-172| Color Macro 43
173-176| Color Macro 44
177-180| Color Macro 45
181-184| Color Macro 46
185-188| Color Macro 47
189-192| Color Macro 48
193-196| Color Macro 49
197-200| Color Macro 50
201-204| Color Macro 51
205-208| Color Macro 52
209-212| Color Macro 53
213-216| Color Macro 54
217-220| Color Macro 55
221-224| Color Macro 56
225-228| Color Macro 57
229-232| Color Macro 58
233-236| Color Macro 59
237-240| Color Macro 60
241-244| Color Macro 61
245-248| Color Macro 62
249-252| Color Macro 63
253-255| Color Macro 64
**Supports Software Versions: ≥ 1.05**
Features subject to change without any prior written notice.
NOTE: ALL SEVEN COLORS USED IN RGBSeven 3CH Mode
MODE / CHANNEL| **VALUE| ****FUNCTION
RGB 3CH| RGBSeven 3CH| 8Bit 7CH| 16Bit 14CH|
Master 15CH| HSI 4CH| HIS Mast 10CH**
| | | | | 3| 9| | HUE – ALL PIXELS
0-255| 0-100%
| | | | | 4| 10| | SATURATION – ALL PIXELS
0-255| 0-100%
1| 1| 1| 1| 9| | | | RED – ALL PIXELS
0-255| 0-100%
| | | 2| | | | | RED FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
2| 2| 2| 3| 10| | | | GREEN – ALL PIXELS
0-255| 0-100%
| | | 4| | | | | GREEN FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
3| 3| 3| 5| 11| | | | BLUE – ALL PIXELS
0-255| 0-100%
| | | 6| | | | | BLUE FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
| | 4| 7| 12| | | | WHITE – ALL PIXELS
0-255| 0-100%
| | | 8| | | | | WHITE FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
| | 5| 9| 13| | | | AMBER – ALL PIXELS
0-255| 0-100%
| | | 10| | | | | AMBER FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
| | 6| 11| 14| | | | LIME – ALL PIXELS
0-255| 0-100%
| | | 12| | | | | LIME FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
| | 7| 13| 15| | | | UV – ALL PIXELS
0-255| 0-100%
| | | 14| | | | | UV FINE – ALL PIXELS
0-255| 16-bit FINE Adjustment
COL OR MACROS CHART
Color Macro | DMX Value | Color Intensity |
---|---|---|
Red | Green | Blue |
Off | 0 | 0 |
1 | 1 – 4 | 80 |
2 | 5 – 8 | 80 |
3 | 9 – 12 | 77 |
4 | 13 – 16 | 117 |
5 | 17 – 20 | 160 |
6 | 21 – 24 | 223 |
7 | 25 – 28 | 255 |
8 | 29 – 32 | 255 |
9 | 33 – 36 | 255 |
10 | 37 – 40 | 255 |
11 | 41 – 44 | 255 |
12 | 45 – 48 | 255 |
13 | 49 – 52 | 255 |
14 | 53 – 56 | 255 |
15 | 57 – 60 | 255 |
16 | 61 – 64 | 238 |
17 | 65 – 68 | 196 |
18 | 69 – 72 | 150 |
19 | 73 – 76 | 100 |
20 | 77 – 80 | 77 |
21 | 81 – 84 | 67 |
22 | 85 – 88 | 77 |
23 | 89 – 92 | 77 |
24 | 93 – 96 | 158 |
25 | 97 – 100 | 255 |
26 | 101 – 104 | 255 |
27 | 105 – 108 | 255 |
28 | 109 – 112 | 255 |
29 | 113 – 116 | 151 |
30 | 117 – 120 | 151 |
31 | 121 – 124 | 138 |
32 | 125 – 128 | 255 |
33 | 129 – 132 | 255 |
34 | 133 – 136 | 254 |
35 | 137 – 140 | 254 |
36 | 141 – 144 | 254 |
37 | 145 – 148 | 254 |
38 | 149 – 152 | 176 |
39 | 153 – 156 | 96 |
--- | --- | --- |
40 | 157 – 160 | 234 |
41 | 161 – 164 | 224 |
42 | 165 – 168 | 175 |
43 | 169 – 172 | 119 |
44 | 173 – 176 | 147 |
45 | 177 – 180 | 88 |
46 | 181 – 184 | 0 |
47 | 185 – 188 | 0 |
48 | 189 – 192 | 52 |
49 | 193 – 196 | 1 |
50 | 197 – 200 | 0 |
51 | 201 – 204 | 255 |
52 | 205 – 208 | 0 |
53 | 209 – 212 | 0 |
54 | 213 – 216 | 0 |
55 | 217 – 220 | 1 |
56 | 221 – 224 | 0 |
57 | 225 – 228 | 209 |
58 | 229 – 232 | 42 |
59 | 233 – 236 | 0 |
60 | 237 – 240 | 8 |
61 | 241 – 244 | 107 |
62 | 245 – 248 | 165 |
63 | 249 – 252 | 0 |
64 | 253 – 255 | 0 |
TECHNICAL SPECIFICATIONS
SOURCE
- 7x 25W 7-IN-1 RGBAW + Lime + UV LEDs
- 50,000 Hour Average LED Life*
- *May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
- Seven Color RGB 3 Channel DMX Mode
- Hue, Saturation, and Intensity DMX Modes
- Internal Programs and Color Macros with Variable Effect Control Variable Electronic Strobe Effects and Dimming Curve Modes
COLOR
- RGBAW + Lime + UV (395nm)
CONTROL / CONNECTIONS
- (7) DMX Channel Modes (15 total channels)
- DMX and Manual Control
- 4 Button OLED Menu Control Display
- Adjustable Refresh Rate (900-25,000 (Hz)
- Adjustable Gamma Brightness (2.0, 2.2, 2.4, 2.8)
- RDM (Remote Device Management) Protocol Support
- IP Rated 3/5pin DMX In/Out
- IP65 Power In/Out
SIZE / WEIGHT
- Length: 11.24” (286mm)
- Width: 10.71” (272mm)
- Vertical Height: 7.36” (187mm)
- Weight: 11.0 lbs. (5.0kg)
ELECTRICAL / THERMAL
- AC 100-240V – 50/60Hz
- 185W Max Power Consumption
- 5°F to 113°F (-15°C to 45°C)
APPROVALS / RATINGS
- CE | IP65
Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
device uses and can radiate radio frequency energy and, if not installed and
used in accordance with the included instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this device does
cause harmful interference to radio or television reception, which can be
determined by turning the device off and on, the user is encouraged to try to
correct the interference by one or more of the following methods:
- Reorient or relocate the device.
- Increase the separation between the device and the receiver.
- Connect the device and the radio receiver to electrical outlets on separate circuits.
- Consult the dealer or an experienced radio/TV technician for help.
DIMENSIONAL DRAWINGS
Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
OPTIONAL ACCESSORIES
ORDER CODE | ITEM |
---|---|
QUICK RIG CLAMP | Low Profile Quick Release Clamp |
SIXPAR/BD100 | Barn Door for SEVEN PAR 7IP |
STR514 | 3 ft. (1m) 5pin XLR Cable |
NEU088 | 3 ft. (1m) Power Link Cable |
Additional Cable Lengths Available |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>