MARTEC MBHL1000S Bathroom Heater Linear Halogen Heat Instruction Manual
- June 25, 2024
- martec
Table of Contents
MARTEC MBHL1000S Bathroom Heater Linear Halogen Heat
Product Specifications
- Product Name: Martec Bathroom Heater Linear 3 in 1
- Features: Halogen Heat, LED Light, Fan 3 in 1
- Installation Compliance: Australia and New Zealand wiring rules AS/NZS3000:2000
- Vent Hole Diameter: 155mm
- Ventiduct Diameter: 150mm
- Maximum Distance from Ground for Optimal Heating: 2.3m
Product Usage Instructions:
Cutting a Vent:
Locate a vent position on the wall, cut a 155mm diameter hole at the position.
Ducting:
Insert the 150mm diameter ventiduct into the vent hole, seal the space around
the hole using a suitable sealant.
FAQ (Frequently Asked Questions):
Q: Do I need to purchase any additional cables for installation?
A: Yes, the main supply and interconnecting cables required are not included
in the package.
BATHROOM HEATER LINEAR
HALOGEN HEAT / LED LIGH T/ FAN 3 IN 1
Dear customers,
Thank you for selecting Martec Bathroom Heater Linear 3 in
- Please read all instructions before commencing installation.
IMPORTANT: This unit must be installed to comply with the appropriate
council regulations and the Australia and New Zealand wiring rules
AS/NZS3000:2000 or latest edition thereof.
The main supply and interconnecting cables required for the installation of
this unit are not included.
WARNING – INSTALLATION ONLY TO BE BY QUALIFIED PERSONS
- Use this heater only as described in this manual. The manufacturer does not recommend any other use as this may cause fire, electric shock, or injury to persons. If you have questions, contact the manufacturer or local agent.
- All wiring must be carried out by a Licensed Electrician in accordance with all applicable codes and standards.
- Make sure the power is off before the installation.
- When cutting into the wall, do not damage electrical wiring and other hidden utilities.
- The heater must be properly grounded.
- The heat lamp and glass shield are hot when in use. Do not touch the heat lamp and glass shield with any part of your body when in use.
- For the purpose of avoiding any dangerous gas leaking into your bathroom, the ventiduct of the heater must not be laid together with the ventiduct of the air-fueled water heater or other open-fire appliances into the same flue.
- The disconnection may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules. The heater must be isolated from the power by means of a plug or all-pole disconnection switch with a contact separation of at least 3mm in each pole.
- The power cable must stand a minimum 10A load.
- The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- The heater is to be installed so that switches and other controls cannot be touched by a person in the bath or shower.
- The appliance shall, under no circumstances, be covered with insulating material or similar material.
- Regulations concerning the discharge of air have to be fulfilled.
- Joists, beams and rafters shall not be cut or notched to install the appliance.
IMPORTANT CONSIDERATIONS BEFORE INSTALLING
A few minutes of planning can make a big difference to the installation time and also to your satisfaction with the function of the unit.
- The unit should not be installed directly above a shower or bathtub. The unit must not be installed in a position where water may splash onto the unit.
- The unit must not be installed beneath a fixed socket or power outlet.
- The unit is designed for installation in flat ceilings only. Do not mount it on a sloping ceiling or a vertical wall.
- The heat lamp is most effective when you are standing directly beneath them, so generally the unit would be mounted a place where you would stand to dry yourself.
- For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. Generally, this air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will function poorly.
- Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall switches to the mounting location.
INSTALLATION
-
Cutting a vent
Locate a vent position (above the ceiling) on the wall, and then cut a 155mm diameter hole at this very position. -
Ducting
Put one end of the 150mm diameter ventiduct into the vent hole and seal space around the hole using a suitable sealant and cowling where necessary.
Note: Since the length of each duct is 3.0m, make sure that from the centre of the installation position there should be a distance within 3.0m to the outside vent. -
Suitable location
For the purpose of obtaining the best heating results, the heater should be no more than 2.3m from the ground after the heater is well fixed. -
Prepare the ceiling
Select the mounting position for the unit. Before commencing any cutting, check in the ceiling space that there are no obstructions such as joints and that there is sufficient height clearance for the housing.
Cut around the attached hole-cutting template and use this template to mark the hole outline on the ceiling.
Make sure the distance between the edges and wall is no less than 250mm. Also the rooftop should be a minimum 210mm height to the ceiling. -
Remove the fascia Remove 4 silicon clips at 2 ends of the rectangle air inlet grilles. Remove the screws hidden inside. Remove the fascia.
Note: Hold the fascia carefully with hand while removing the screws so that the fascia doesn’t fall to the ground. -
Remove the lamps
-
Remove 4 LED lamps from the heat unit and keep them in a safe place.
-
The heat lamp is not installed on the unit. It is packed together with the glass shield inside a separate foam package, please keep it in a safe place.
-
Wiring
Connect one end of the interconnecting wire with the switch panel, and then drag the other end power cable out of the hole on the ceiling. Open the terminal block cover on the housing and make the connection as the wiring diagram instructs, then reposition the terminal block cover. Tuck the redundant wire into the ceiling so as to leave the housing enough room to fix in.
Note: Ensure that the power is turned off before carrying out any work on electrical installations. -
Fit the in-house end of the duct to the fan outlet, and fix the end with duct clip.
Note: Keep the route as straight as possible. -
Position the housing into the hole
Choose an optimal direction to put the housing into the hole in accordance with the position of the fan outlet. Ensure that the unit is held securely on all 4 sides. You may have to add battens on 2 sides in between joists or even build a frame to secure it properly into the ceiling with battens.
Note: Try to keep the redundant wire away from the housing. -
Final installation
-
Install the heat lamp.
Take out the heat lamp from the foam package. The heat lamp is half coated with a white reflector. When you grasp the heat lamp, face the back of the reflector to the ceiling so you can see the heat lamp’s filament. Not doing this will reduce performance. Ftt one end of the heat lamp into the socket and gently push tt away from the other socket. When there is enough room, fit the other end of the heat lamp into its socket. Note: Natural skin oil and salts damage new halogen lamps and shorten their life. Only handle a new heat lamp with soft, dry, clean, lint-free cloth or paper. You can wear gloves, cover your fingers or wrap the heat lamp until tt is installed (so long as you remove all cloth or paper when finished). -
Replace the LED lamps.
-
Install the glass shield to the fascia.
The glass shield makes the light soft so tt can reduce the discomfort to your eyes. Take out the glass shield from the foam package. Insert the glass shield into the slots on the fascia. Be careful while handling to avoid any damage to the glass shield.
Note: Make sure the glass shield is well fixed by the springs inside the slots. -
Replace the fascia.
Replace the fascia to the unit and fix the fascia by screws. Use 4 silicon clips to cover the screws. -
Fix the switch panel to the wall.
Note: The switch wiring should be mounted inside the wall to give the switch an integrated built-in appearance. If tt is necessary to run the wiring on the outside of the wall, use a suitable conduit and fixings to properly locate and hold the wiring used.
For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. In general, this air would be drawn from under the door, or through a slightly opened window. If the room is air-tight, the fan will function poorly.
USE
Our bathroom heater uses a halogen heating lamp as a source of heat.
It also combines the functions of exhaust and light.
-
Heat
‘HEAT’ button On/Off
Note: Do not touch the infrared lamps with any part of your body when ‘1nuse. -
Exhaust
‘FAN’ button On/Off
This unit can exhaust odors and steam in a quick and efficient way by turning on the “FAN” button. -
Lighting
‘Light’ button On/Off
Note: Do not switch on/off frequently when in use. Shut off the power if in long vacancy.
PLEASE NOTE:
Triple Thermal Protection System: The Linear is equipped with a 90-degree
resettable thermal switch to activate the exhaust fan, a 100-degree resettable
thermal switch to cut off the power supply to the halogen heater, and a
121-degree thermal fuse to cut off the power supply to the halogen heater.
MAINTENANCE
-
Clean
-
Shut off the power before cleaning.
-
Wipe the glass shield and fascia with care using a soft cloth soaked with a neutral detergent. Check the glass shield is not loose from the slots regularly.
Note: Ensure the lamps are cool enough to touch before handling. -
2. Lamp Replacement
-
Check the heat lamp regularly.
-
Shut off power before replacement.
-
Use Martec 6W GU10 LED Lamp MBGU306 for lighting.
-
Use Martec MRL 100OWleat lamp for heating.
Note: It may affect operation (even cause danger) when lamps, other than the designated ones, are used.
WARRANTY
The unit is warranted against defects in manufacturing and workmanship for a
period of 2 years. The warranty does not extend to lamp globes supplied or
installation of the unit or any associated wiring or any damage caused by
installation or wiring.
The installation must be conducted by a licensed electrician and a suitable
certificate of safety is to be issued by the electrician who installed the
unit. Warranty claims will be voided unless a certificate of safety can be
produced when required, prior to service or repair.
This warranty does not cover damages or loss caused by:
- Heat or light lamps.
- Any consequential losses arising from incorrect installation or operation or maintenance of this product.
- Any consequential losses arising from incorrect wiring of this product.
- Any modifications or changes made to the unit, other than those recommended by the Manufacturer.
AC Required Statement
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to Martec replacing the product in a home with
parts and labor for a major failure. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure. Martec offers an in-home warranty
that includes parts and labor so the end consumer is not out of pocket.
MAIN TECHNICAL PARAMETERS
LIST OF ACCESSORIES
Fill out the following details and file with the purchase Invoice for warranty
service.
MODEL NO.:
Purchased from:
Dale of purchase:
ARTEC
ABN: 82 599 302 308
We reserve the rights to revise this instruction without any prior notice.
Please use this card as hole cutting templa te 455mm x 305mm.