SIGLENT 2024 High Resolution Oscilloscope User Guide
- June 25, 2024
- SIGLENT
Table of Contents
- SIGLENT 2024 High Resolution Oscilloscope
- FAQ
- Key Specifications
- Key Design Features
- Visualization Tools
- Analysis Tools
- Advanced Communication Analysis with the SDS7000A Series
- High Resolution Key Applications
- SIGLENT High Resolution Comparison Chart
- Resource & Document Links
- About SIGLENT
- Contacts
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SIGLENT 2024 High Resolution Oscilloscope
FAQ
Frequently Asked Questions
- What is the importance of oversampling capability in signal analysis?
- Oversampling capability is crucial for signal analysis as it provides flexibility in bandwidth and filtering to optimize signal fidelity.
- How does quantization error affect ADC resolution?
- Quantization error is the voltage difference between consecutive values on the ADC. Each additional bit in resolution halves the quantization error. A higher bit ADC provides better resolution and accuracy in signal capture.
Key Specifications
When comparing oscilloscopes or determining their value in a given application, there are a few top-level specifications that usually come up:
- Sampling Rate
- Resolution
- Memory
- Bandwidth/filtering
These 4 specifications actually work together in a number of ways that create tradeoffs and capability for a number of applications. Let’s look at what they each mean and how they interact in common use cases.
Sampling Rate
- Sampling rate and sampling precision affect analysis and measurements of time and frequency. We measure this in GSa/sec. This is especially true for frequency measurements made by FFT.
- One downside is that higher frequency sampling will capture and display higher bandwidth noise. This is also true of higher actual bandwidth.
- What sampling do we typically see in High-Resolution scopes? There are a wide range of 10 and 12 bit oscilloscopes available on the market. Start by selecting an oscilloscope with at least 2.5 times the frequency you want to measure or analyze. Many oscilloscopes’ sampling can change with the number of active channels.
As we will see, having extra oversampling capability can be very important to signal analysis because it allows the engineer flexibility in bandwidth and filtering to optimize their signal fidelity.
Series | Max Sampling | Max 4 channel Sampling |
---|---|---|
SDS800X HD | 2 GSamples/sec | 500 MSamples/sec |
SDS1000X HD | 2 GSamples/sec | 500 MSamples/sec |
SDS2000X HD | 2 GSamples/sec | 1 GSamples/sec |
SDS3000X HD | 4 GSamples/sec | 2 GSamples/sec |
SDS7000A H12 | 20 GSamples/sec | 10 GSamples/sec |
Resolution
- True Resolution is equivalent to the number of bits captured by the ADC for each sample. Additional bits of resolution are often discussed as a result of filtering or averaging. But we need to start with true resolution.
- Quantization error is the voltage difference between consecutive values on the A2D itself.
- Each additional bit drops the quantization error in half. Everything else being equal, a 12-bit ADC has a quantization error of 1/16th of an 8 bit ADC. As we will see though, if you design an oscilloscope for signal fidelity everything else isn’t equal.
- From a specification perspective, the quantization is typically rolled into the offset error for a given scope range.
Memory Depth
Memory, Bandwidth, and filtering are specifications that work with sample rate and resolution to create opportunities and tradeoffs. First, memory and sampling work together to bound the longest time that can be captured with maximum sampling and bandwidth. For instance, an oscilloscope like the SDS7000A with up to 1 billion points of memory can capture a channel at 20 GSa/sec for 50 ms total. This means you can set the horizontal to 5 ms/div and still fully capture the 4 GHz signal. This is useful for slow developing signals or rare signal artifacts. The SDS7000A can then zoom in millions of times to view fast signal artifacts in context.
Bandwidth/filtering
Most applications, even for performance scopes, don’t require max bandwidth
for most measurements. This is where the memory can be used flexibly and
purposed specifically to the application.
This is effectively a type of boxcar filtering where combining consecutive
samples in groups allows us to further reduce the quantization error by
estimating voltage levels between actual bits. This ability to optimize is
dramatically reduced if the scope starts out short on memory or sample rate.
These tradeoffs create opportunities to improve and optimize noise and
ultimately signal fidelity within a smaller bandwidth. Using this method,
effectively reduces the bandwidth along with the sampling reduction.
Here is an example of the filtering options available on the SDS7404A.
Exceptionally deep memory means that even when consuming a number of samples
to generate a single filtered data point, the instrument can still capture
long enough events for debug and analysis.
Make sure to understand the tradeoffs and requirements for memory, sampling, and bandwidth in the application.
Key Design Features
Overall design quality is more important to the actual signal fidelity than just the number of bits on the analog to digital converter. There are 3 key facets of design for signal fidelity where SIGLENT’s high resolution oscilloscopes excel:
- Noise
- Gain Accuracy
- Isolation
Noise
Low noise design starts with component selection, EMI, and power cleanliness in the front end. Noise increases with bandwidth and sampling rate. An oscilloscope’s noise can be characterized by range, bandwidth, and configuration. It’s important to start with good performance at full bandwidth and sampling, but then as we saw in the SDS7000A table above, the noise can be optimized by trading off bandwidth and sampling via filtering. SIGLENT oscilloscopes have an additional channel independent hardware bandwidth limit filter that can further address noise. In some tests, these limits are more effective than filtering. In this excerpt from the SDS7000A table with an additional line, we see that the BW limit eliminates more noise than the step beyond it in filtering:
Setup | Bandwidth (MHz) | µVrms Noise |
---|---|---|
ERES 2.5 bits | 280 | 52 |
2.5 ERES bits + BW
Limit 200 MHz
| 200| 38
ERES 3 bits| 140| 42
Gain Accuracy
Measurement precision requires careful design and innovation throughout the instrument. DC Gain Accuracy is an important component of precision that defines the error in a measurement as the signal moves further away from ground. SIGLENT’s HD Oscilloscopes improve upon gain accuracy beyond competitive oscilloscopes. This makes it possible to accurately visualize signals even as they ride on top of other signals or voltage levels. This is critical to expanded scale offsets which is an important visualization tool.
Compare SIGLENT Oscilloscopes to the specifications for competitive midrange and performance oscilloscopes:
Brand | Series | Range | DC Gain Accuracy |
---|---|---|---|
SIGLENT | All X HD Scopes | ≥5mV/div | 0.5% |
R & S | RTB2000 | >5mV/div | 1.5% |
Keysight | MSOX2000A | ≥10mV/div | 3% |
Tektronix | MSO 2 Series | all | 3% |
SIGLENT | SDS7000A | ≥5mV/div | 0.5% |
Tek | MSO64B | ≥2mV/div | 1% |
Keysight | EXR | all | 1% |
R & S | RTO2000 | ≥5mV/div | 1.5% |
Isolation
Isolation – often expressed as a ratio. This is the error injected to our signal from another channel’s signal path. This is largely related to layout, part quality, and EMI design considerations. It can be important to look out for oscilloscopes with surprisingly low isolation as this may also leave them susceptible to other coupling or noise sources.
High-Res Competitor | SDS2000X HD | |
---|---|---|
Channel isolation | >100:1,< 500 MHz | >1000:1, < 500 MHz |
3000:1, < 350 MHz
Improved isolation, gain accuracy, and noise performance work together to provide a high signal fidelity platform for measurements and analysis of signals.
Design for Signal Quality
SIGLENT’s design for signal quality means we have some of the most accurate high-resolution scopes on the market. When compared to brand label high resolution scopes (per their datasheets above), our overall accuracy is very competitive. When compared to 8 bit oscilloscopes or value high resolution models, SIGLENT demonstrates exceptional accuracy and signal fidelity.
Visualization Tools
Many oscilloscope applications focus on signal visualization for verification. The tools and capabilities provided to improve the visual experience of an oscilloscope are some of the most important for engineers. Three key visualization tools that are improved by SIGLENT’s high resolution design are:
- Vertical Zoom
- Scale Offset
- FFT
Vertical Zoom
While all modern scopes have zoom capability, not all have a powerful vertical zoom. With high resolution and a good design, signal artifacts can be discovered in less than 0.1% of the capturing range. The zoom window (bottom half) shows a 20X zoom on the vertical scale for a small section of the time base.
Scale Offset
Wider offset capabilities are important as they allow engineers to get more
out of the high resolution by using a smaller range to visualize a signal away
from ground. This reduces quantization noise, improving zoom function.
Remember 8 to 12 bits is a 16X decrease in quantization error. In many cases,
SIGLENT’s wider range allows for 8X the offset meaning that when testing
applications like evaluating a small signal riding on a larger signal, scale
offset can be as valuable as 3 extra bits of resolution.
With more ranges and more range offset capability, SIGLENT scopes can utilize lower ranges for more signals, further improving usability of the noise and resolution. See how the SIGLENT lowers quantization error when measuring signals offset nd:
- At many offset voltages, SIGLENT’s range is 10x better for small signal capture than competitive oscilloscopes.
- The combination of vertical zoom and robust scaling on the front end provides excellent flexibility in usability and visualization for a wide range of signals.
FFT Quality
The combination of high resolution and excellent design quality has a large
impact on RF measurements as well. Visualizing signals using the FFT is
improved by these factors and is important in many mixed domain, EMI, and
analysis applications.
SIGLENT high-resoultion oscilloscopes offer up to 32 Mpts of 12 bit data in
the FFT.
For instance, you can set up a 100 MHz span with 4 MPt that has a 386 Hz RBW. With the full 32 MPts you can produce a 1 GHz span with 482 Hz RBW and a sample rate of 10 GSa/sec. This creates frequency points less than 300 Hz apart across that span:
- Combine this with markers, peak readings, and scaling tools to capture signals equivalent to a wideband Real-Time Spectrum Analyzer that you can correlate with your other time domain signals.
- Isolation is critical in these applications as well since RF signals are especially good at creating crosstalk on adjacent channels.
Analysis Tools
- Many oscilloscope applications require advanced statistical analysis. Increased resolution and a design for signal quality make these tools even more productive.
Histogram & Statistical Measurements
View more than 50 measurements of channel data or view multiple histograms for additional debugging and analysis:
Power Analysis
Power Analysis is used to verify and debug power supply designs. Using a
combination of FFTs and arithmetic functions on current and voltage readings,
important aspects of a power design can be analyzed including safe operating
area, harmonics, ripple, inrush current, and more.
Low noise, isolation, filtering, and FFT quality all have an important impact
on these measurements.
All SIGLENT high resolution oscilloscopes can conduct power analysis, but select for advanced ERES filtering capabilities and automatic probe interfaces on the SDS3000X HD or SDS7000A series.
Serial Decode
Serial bus decoding is important for design and debug of many electronics including IoT systems. Analyzing RF and analog signals together is the best way to determine root cause and improve firmware or hardware operation. This type of mixed domain analysis is an important application for high resolution oscilloscopes.
All SIGLENT high resolution oscilloscopes offer:
- I2C, SPI, UART, CAN, LIN
Advanced models also offer:
- CAN FD, FlexRay, I2S, MIL-
- STD-1553B, SENT, Manchester, ARINC429, and USB2.0
Zone Trigger
- On the SDS2000X HD, SDS3000X HD and SDS7000X HD add visual zone triggering to traditional triggering options.
- Utilize zone triggering to identify infrequent or unusual events or combinations of events for complex debugging challenges.
- Additional debugging capabilities include methods to search through captured signals for anomalies and ultimately find root cause.
Search & Navigate
- Search and mark events, then navigate by time or frames to review on screen.
- Split the memory into segments and review these sequences of trigger events using Sequence mode and combine this with temperature display mode, zone trigger, and persistence views.
- Or use the history mode to automatically capture and allow playback of waveforms to locate signals of interest over time.
- Search Analysis Capabilities for SIGLENT High Resolution Oscilloscopes:
Series | History or sequence frames | Sequence minimum interval |
---|---|---|
SDS800X HD | 80,000 | 2 µsec |
SDS1000X HD | 80,000 | 2 µsec |
SDS2000X HD | 80,000 | 2 µsec |
SDS3000X HD | 80,000 | 1.2 µsec |
SDS7000A H12 | 124,000 | 0.9 µsec |
Bode Plot Analysis
Frequency Analysis is a specialized application for devices like amplifiers, filters, and attenuators that graphs gain and phase relationship changes over frequency on a bode plot. This is an example of RF or high-speed device testing that is an important capability for high resolution oscilloscopes.
Frequency analysis benefits from improved signal quality for accuracy in gain
measurements as well as sampling and resolution to monitor phase changes. With
multiple channels and an automated test sequence, isolation and range
optimization are also important.
Power supply loop response is a popular test using this configuration.
All SIGLENT high resolution oscilloscopes can conduct bode plot analysis, but
select for 50 Ohm capabilities, embedded or separate generators, and display
size.
Advanced Communication Analysis with the SDS7000A Series
Jitter Analysis & Real Time Eye Diagrams
Take analysis even further with applications packages that utilize the histogram and deep memory capabilities of the SDS7000A series including Jitter and Real Time Eye:
- The Jitter toolkit includes multiple views for analyzing random, deterministic, period jitter, and more. Combine histograms, trends, and spectrum views for signals of interest. The bathtub display is an important view for jitter decomposition.
- High sample rate and deep memory enable accurate characterization of frequency changes within the clock signal with enough signal fidelity to debug and analyze the underlying statistics.
- Real Time Eye visualizes communication signals with bandwidth, noise, and jitter. It includes eye measurements as well as custom mask settings. Deep memory is folded over into frames within the eye diagram to generate statistical data for these communication signals.
- Jitter and Real-Time Eye are available in the SDS7000A-EJ option.
- Custom mask testing is a hardware function available on all SIGLENT high resolution oscilloscopes, but is especially useful in eye diagram testing on the SDS7000A.
Compliance Packages
- Also available on the SDS7000A series are compliance packages for USB 2.0, 100Base-TX, 1000Base-T, 100Base-T1, and 1000Base-T1.
- These are automated test that work with an accessory fixture to complete the test and generate a report that can be viewed or archived.
Fixtures:
High Resolution Key Applications
Mixed Domain Debugging
- Compare digital, analog, and RF signals to find the root cause of an issue on the first try.
- Utilize decoding, FFT quality, window views, and SIGLENT design for signal quality to quickly debug complex IoT devices and systems.
Logic Analysis
Add Logic Analysis to any SIGLENT high resolution oscilloscope to analyze 16 channels of digital signals alongside the analog channels by adding one of the logic probes and the 16LA option license:
Series | Logic Probe | Max Memory | Max Sampling |
---|---|---|---|
SDS800X HD | SLA1016 | 10 MPts/ch | 1 GSa/sec |
SDS1000X HD | SLA1016 | 10 MPts/ch | 1 GSa/sec |
SDS2000X HD | SPL2016 | 50 MPts/ch | 500 MSa/sec |
SDS3000X HD | SPL2016 | 100 MPts/ch | 1 GSa/sec |
SDS7000A H12 | SPL2016 | 100 MPts/ch | 1 GSa/sec |
Signal on Signal Analysis
- Capture and analyze small signals with precision and accuracy even in the presence of larger signals or offsets.
- EMI, isolation, and other signal fidelity challenges can cause design and reliability problems.
- Quickly identify and resolve issues with SIGLENT’s design for quality that provides a low noise environment with visualization tools to debug on the fly.
- This image shows a small aberrant pulse train on top of large square wave with overshoot making it difficult to trigger on. Dynamic ranges and vertical zoom work together with persistence modes to make this signal easy to capture.
Power Supply Design Testing
- Power supply design challenges require complex and accurate signal analysis.
- Utilize the visualization tools, probe options, and power analysis toolkit to characterize the complete power system with high resolution and improved signal fidelity.
- New SCP5000 series current probes are powered directly from the probe interface on the SDS3000X HD or SDS7000A oscilloscopes.
Frequency Analysis
Bode plot analysis characterizes how devices operate across frequency. Enable this advanced function by adding an external waveform generator or enabling a built-in generator along with the FG option license depending on the oscilloscope model. Accurate measurements across frequency extends the value of a bench top oscilloscope with added automation and capabilities.
SIGLENT High Resolution Comparison Chart
Specifications|
SDS800X HD
|
SDS1000X HD
| ****
SDS3000X HD
|
SDS7000A
---|---|---|---|---
Bandwidth| 70-100 MHz| 100-200 MHz| 350 MHz – 1 GHz| 3-4 GHz
Vertical resolution| 12 bits
ERES bits| | | +4 bits| +4 bits
Analog channels| 2-4| 2-4| 4| 4
Max sample rate| 2 GSa/sec| 2 GSa/sec| 4 GSa/sec| 20 GSa/sec
All channels max sample rate| 500 MSa/sec| 500 MSa/sec| 2 GSa/sec| 10 GSa/sec
Max Memory depth| 50 Mpts| 100 Mpts| 400 Mpts| 500 Mpts (1Gpts opt)
Normal Waveform capture rate| 80,000| 120,000| 200,000| 1,000,000
Impedance| 1 MΩ| 1 MΩ and 50 Ω| 1 MΩ and 50 Ω| 1 MΩ and 50 Ω
Noise Floor (uVrms) (typ)| 70 uVrms @ 200 MHz| 70 uVrms @ 200 MHz| 125 uVrms @
1 GHz| 220 uVrms @ 4 GHz
ENOB (typ)| 8.4| 8.4| 8.2| 7.3
Touchscreen size| 7”| 10.1”| 10.1”| 15.6”
Isolation| >40dB| >40dB| 50 dB up to 500 MHz| 60 dB up to 500 MHz
Zone Trigger| | | Supported| Supported
Serial Decode
| I2C, SPI, UART, CAN, LIN| I2C, SPI, UART, CAN, LIN| I2C, SPI, UART, CAN, LIN options: CAN FD, FlexRay, I2S, MIL-STD-
1553B, SENT, Manchester,
ARINC429, USB 2.0
| I2C, SPI, UART, CAN, LIN options: CAN FD, FlexRay, I2S, MIL-STD-
1553B, SENT, Manchester,
ARINC429, USB 2.0
Sequence segments| 80,000 with 2 us dead time| 80,000 with 2 us dead time|
80,000 with 1.2 us dead time| 124,000 with 0.9 us dead time
History Frames| 80,000| 80,000| 80,000| 124,000
Max FFT Depth| 2 Mpts| 2 Mpts| 4 Mpts| 32 Mpts
Video Output| | | | HDMI, DisplayPort
Probe Support| passive| auto recognize passive| All| All
Resource & Document Links
Scope Family Documents
- SDS800X HD Series Web Page
- SDS800X HD Series Manuals
- SDS1000X HD Series Web Page
- SDS1000X HD Series Manuals
- SDS3000X HD Series Web Page
- SDS3000X HD Series Manuals
Additional Documents
Signal Fidelity Webinar Video
Oscilloscope Usage Tips
About SIGLENT
SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments.
SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, isolated handheld oscilloscopes, function/arbitrary waveform generators, RF/MW signal generators, spectrum analyzers, vector network analyzers, digital multimeters, DC power supplies, electronic loads and other general purpose test instrumentation. Since its first oscilloscope was launched in 2005, SIGLENT has become the fastest growing manufacturer of digital oscilloscopes. We firmly believe that today SIGLENT is the best value in electronic test & measurement.
Contacts
Headquarters:
- SIGLENT Technologies Co., Ltd
- Add: Bldg No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101, China
- Tel: + 86 755 3688 7876
- Fax: + 86 755 3359 1582
- Email: sales@siglent.com
- Website: int.siglent.com
North America:
- SIGLENT Technologies America, Inc 6557 Cochran Rd Solon, Ohio 44139
- Tel: 440-398-5800
- Toll Free: 877-515-5551
- Fax: 440-399-1211
- Email: info@siglentna.com
- Website: www.siglentna.com
Europe:
- SIGLENT Technologies Germany GmbH
- Add: Staetzlinger Str. 70 86165 Augsburg, Germany
- Tel: +49(0)-821-666 0 111 0
- Fax: +49(0)-821-666 0 111 22
- Email: info-eu@siglent.com
- Website:www.siglenteu.com
Follow us on Facebook: SiglentTech
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>