Kasco 2400 Floating Surface Aerator 1/2 HP Fountains 2 Go Instruction Manual
- August 28, 2024
- Kasco
Table of Contents
- Kasco 2400 Floating Surface Aerator 1/2 HP Fountains 2 Go
- SAFETY FIRST
- UNIT SPECIFICATIONS
- GENERAL INSTRUCTIONS
- SUGGESTED TOOLS & SUPPLIES
- PARTS INCLUDED
- ASSEMBLY INSTRUCTIONS
- INSTALLATION INSTRUCTIONS
- MAINTENANCE RECOMMENDATIONS
- TROUBLESHOOTING TIPS
- UNIT REPLACEMENT PARTS
- WARRANTY
- REPAIR CONTACT FORM
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 2 Phillips-head screwdriver
Kasco 2400 Floating Surface Aerator 1/2 HP Fountains 2 Go
Specifications
- Model: 2400A, 3400A, 3400HA, 4400A, 4400HA
- Voltage: 110-120 (for 2400A, 3400A, 4400A), 208-240 (for 3400HA, 4400HA)
- Operating Amps Single-phase Aerators: 5.0 (2400A), 6.7 (3400A), 3.4 (3400HA), 9.1 (4400A), 5.7 (4400HA)
- Locked Rotor Amps: 12 (2400A), 18 (3400A), 9 (3400HA), 40 (4400A), 20 (4400HA)
Assembly Instructions
- Rest the float on the cage, aligning the power cord to the notch in the float.
- Locate the bolt holes marked with the indicators.
- Secure the float to the cage with the provided screws, washers, and float retaining clips.
General Instructions
Inspect the Shipment: Immediately inspect your shipment for any visible
damages and report them to your carrier and Kasco.
Assembly & Installation: Follow the specific assembly and installation
instructions provided in the manual for your model and size of aerator. Test
the GFI breaker in the control panel after each installation/re-installation
to ensure proper functioning.
Parts Included
Item Description | Qty | Part No. |
---|---|---|
A – 1/4-20 x 3-1/2 screw | 3 | 251210 |
B – 1/4 split lock washer | 3 | 840537 |
Frequently Asked Questions (FAQ)
Q: How often should I inspect my Kasco aerator?
A: It is recommended to inspect your Kasco aerator regularly and especially
after installation to ensure proper operation.
Operation & Maintenance Manual
3020379 ANSI/UL 778: 2016 Ed.6+R:22Feb2017 CSA C22.2 #108: 2014 Ed.5
QUESTIONS?
715.262.4488
kascomarine.com |
support@kascomarine.com
SAFETY FIRST
IMPORTANT : PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE
Please read and follow these extremely important safety and handling
instructions for your Kasco equipment. Following these instructions will help
ensure your safety and the quality performance of your equipment.
- Under NO circumstances should anyone enter the water with the electrical equipment plugged in and/ or in operation. All Kasco equipment is ETL approved to UL and CSA standards for safety in water. However, it is NEVER recommended to enter the water with the equipment in operation.
- Use caution when dealing with any electrical and/or moving equipment.
- NEVER run the unit out of water. It will damage the seals and create a dangerous situation for the operator.
- Use extreme caution around water, especially cold water, such as in spring, fall, and winter, which poses a hazard in itself.
- NEVER lift or drag the equipment by the power cord. If you need to pull the unit to the side of the pond, use the anchoring ropes or mount apparatus.
- Do not use waders in deep ponds/lakes or ponds/lakes with drop-offs, drastic slopes, or soft bottom material.
- Do not use boats that tip easily, such as canoes, for installation, and follow all boating safety rules and regulations, including wearing a PFD (Personal Flotation Device).
- Single phase water aerators are supplied with an internal grounding conductor and a grounding-type attachment plug. To reduce the risk of electrical shock, be certain that the water aerator is plugged into a GFI-protected circuit.
- Control panels must be installed a minimum of 5ft (1.5m) from the inside wall of the pond, unless separated from the body of water by a fence wall, or other permanent barrier that will make the unit inaccessible to persons in the water.
- Control panels must be installed by a qualified electrician.
- Ground Fault Circuit Interrupters (GFCI) should be tested upon each installation and every month thereafter to ensure proper operation.
- Please keep the original box for maintenance shipping.
UNIT SPECIFICATIONS
Model| Voltage Operating Amps
Single-phase Aerators
| Locked Rotor Amps
---|---|---
2400A| 110-120| 5.0| 12
3400A| 110-120| 6.7| 18
3400HA| 208-240| 3.4| 9
4400A| 110-120| 9.1| 40
4400HA| 208-240| 5.7| 20
GENERAL INSTRUCTIONS
Inspect the Shipment
Immediately inspect your shipment for any visible damages. Any damage should
be reported immediately to your carrier and Kasco.
Assembly & Installation
Please see the proper assembly and installation Instructions enclosed in this
manual. Each is specific for your model and size of aerator. Note: It is
extremely important to test the GFI breaker in the control panel upon each
installation/re-installation of the unit to ensure proper functioning.
Use and Operation
Kasco Aerators are designed and engineered for continuous duty, such as on
fish farms or other aquacultureapplications, or on-demand use, as needed in a
recreational water feature. During flotation operation, the water is pulled
from 360° around the unit and from below the unit. Following installation,
your Kasco aerator is ready for immediate use. Make sure to keep the motor
housing clean from hard water deposits and/or algae. (See Maintenance
Recommendations.) Kasco aerators are lightweight, energy efficient, and easy
to install and operate.
SUGGESTED TOOLS & SUPPLIES
-
2 Phillips-head screwdriver
- 3/8″ socket or wrench
- 9/16″ socket or wrench
- Anchors or stakes for installing unit
- 12″ pieces of 1″ galvanized pipe (optional, see page 8)
PARTS INCLUDED
Item | Description Qty Part No. |
---|---|
A | 1/4″-20 x 3-1/2″ screw |
B | 1/4″ split lock washer |
C | 1/4″, 3/4″ OD flat washer |
D | Float |
E | Float retaining clip |
Optional Bottom Screen Assembly | |
F | 3/8″-16 x 2-1/2″ hex head screw |
G | 3/8″ flat washer |
H | Bottom screen |
I | Bottom screen clip |
J | 3/8″-16 nut |
ASSEMBLY INSTRUCTIONS
-
Rest the float (D) on the cage, aligning the power cord to the notch in the float.
-
Locate the bolt holes marked with the indicators
-
Secure the float to the cage with the 1/4″-20 x 3-1/2″ screws (A), 1/4″ split lock washers (B), 3/4″ OD flat washers (C), and float retaining clips (E), as shown below.
-
Repeat for all three bolt holes.
-
If you are not installing a mesh screen with your bottom screen, continue to step 10.
If you are not installing a bottom screen, continue to step 12. -
Wrap the flat mesh into a cone shape by overlapping both vertical edges by approximately 1 inch and aligning the top and bottom edges of mesh.
-
Use three cable ties evenly spaced along the vertical seam to secure the mesh at the top, middle, and bottom.
-
Center the stainless steel bottom screen inside the mesh cone with approximately 2 inches of mesh above the steel screen’s large ring.
-
Use three cable ties evenly spaced around the large ring to attach the mesh to the steel screen.
-
Use two cable ties placed opposite each other on the small ring to further secure the mesh to the screen.
-
Turn the unit upside down and position the bottom screen (H) flush with the float.
-
Turn the unit upside down and position the bottom screen (H) flush with the float.
-
Fasten the bottom screen to the float using the 3/8″-16 x 2-1/2″ screws (F), 3/8″ flat washers (G), bottom screen clips (I), and 3/8″-16 nuts (J).
-
Loop the mooring lines through either two or three evenly spaced holes on the float.
-
Attach the strain relief to the line closest to the cord. Make sure to clip both the loop and one side of the rope between the knot and the float to ensure the clip doesn’t move down the rope.
-
If your cord does not have a strain relief clamp and chain attached, you can secure the cord to one of the float holes
INSTALLATION INSTRUCTIONS
Use ropes to position the aerator in the desired location in the pond or lake. Anchor the ropes or secure them to the shoreline so that they are free of slack, but not tight. To prevent twisting of the unit due to motor torque, place the anchor at least 3 feet from the float for each foot of depth. (Example: a 6-foot-deep pond would require an anchor 18 feet horizontally from the float.)
Correct anchoring
Mooring lines are proper length and taut between unit and anchors.
Incorrect anchoring
Mooring lines are too short or loose between unit and anchors.
Alternate Installation
In ponds where the water level fluctuates significantly, a small weight may
need to be suspended at the midpoint of the rope to take up any slack caused
by a drop in water level (1 foot of 1-inch galvanized pipe works well). The
weight should be light enough so that the aerator can rise as the water level
rises. This weight can also help hide the anchoring ropes by sinking them
further below the surface.
MAINTENANCE RECOMMENDATIONS
UNDER NO CIRCUMSTANCES should anyone enter the water while equipment is
operating.
The following maintenance procedures can ensure many years of quality
performance from your Kasco aerator and reduce the need for more costly repair
work.
Proper Installation
Proper installation of Kasco equipment will include a power source with Ground
Fault Interruption (GFI). Ground fault interrupters are a safety feature that
can also alert you to electrical leaks in the equipment. It is extremely
important to test the GFI upon installation, following each re-installation,
and monthly thereafter to ensure proper operation. There should only be one
GFCI in a circuit. If you have repeat/consistenttrips on your ground fault,
disconnect the equipment and remove it from the water. Inspect the power cord
for damage and call Kasco Marine at 715- 262-4488 for further instructions.
Kasco recommends placing an extra serial number sticker on the inside of the
control panel cover.
Observation
Operating equipment should be observed on a regular basis (daily, if possible)
for any reduction or variation in performance. If you observe a change in
performance, disconnect the equipment from its power source and inspected for
any material that may have clogged the system or wrapped around the shaft of
the motor, especially plastic bags and fishing line. Even though Kasco
aerators are among the most clog-resistant on the market, it is impossible to
protect against all items that can clog equipment and still maintain a flow of
water. These materials can be very damaging to the equipment under continuous
operation and must be removed as soon as possible.
ALWAYS UNPLUG THE UNIT BEFORE ATTEMPTING TO REMOVE CLOGS.
Winter Storage
In regions where there is significant freezing in the wintertime, remove the
aerator from the water to protect it from the expansion pressure caused by
ice. In many areas, aerators will keep some amount ofice open through the
winter. However, when the water is thrust into the air, it is exposed to the
colder air temperatures longer and can actually make ice thicker on the
pond/lake. Storage over winter is best in a location that is out of the sun
and cool, but above 32 degrees Fahrenheit. During the offseason, store units
upside down (with the float down) if they are going to be sitting for long
periods of time. Units that sit upright on a shelf for many months, or even
years have a greater likelihood of seals drying out. Storing units upside down
will help to ensure oil is lubricating the seals without damaging the
propeller guard.
Cleaning
Aerators should be removed from the water at least once per year (at the end
of the season in cold climates) to clean the exterior of the system,
especially the stainless steel motor housing (can). The motor housing is the
surface that dissipates heat into the water, and any algae, calcium, or other
build-up will become an insulator that blocks heat transfer. In warmer
regions, Kasco recommends removing the motor and cleaning it at least two to
three times per year, depending on conditions. In most cases, a power washer
will be sufficient if the unit and algae are still wet. Avoid power-washing
the mechanical seal area directly.
Seal And Oil Replacement
This is a sealed motor assembly, and seals will wear out over time (similar to
brake pads on a car). Replacing the seals and changing the oil after three
years may add longevity to the operation of the motor, saving you the cost of
more expensive repairs. In warmer climates where the aerator runs most or all
of the year, it is a good idea to replace seals more regularly than you would
need to in colder climates where the unit is removed from the water for
several months.
Sacrificial Anode
A sacrificial anode is supplied on the shaft of all aerators for protection of
the equipment from corrosion and electrolysis. The anode should be updated
(replaced) if reduced to half the original size or if white incolor. Corrosion
from electrolysis is more commonly associated with saltwater or brackish
water, but as a matter of precaution, it is important to periodically check
the anode in all installations (at least every two to three months). Seal
replacement and all other repair services should be performed by Kasco Marine
or a Kasco Authorized Repair Center. Any alterations or changes made to Kasco
units by an unauthorized source will void the warranty. This includes
tampering with the unit, power cord, and/or control box. Please contact Kasco
Marine, Inc. at 715-262-4488 for your
nearest Authorized Repair Center.
TROUBLESHOOTING TIPS
Below are some helpful troubleshooting tips. If a problem occurs, please
double-check the assembly and installation instructions as well as the
instructions for the control panel. More troubleshooting tips can be found at
www.kascomarine.com
My aerator trips the ground fault interrupter in the C-85 or C-95.” This is
the most common symptom of several possible problems. To correctly diagnose
the problem, you will need to collect more information. A Ground Fault
Interrupter (GFI) breaker that trips can indicate an electrical service
problem, water contamination in the unit and/or cord, bad breaker, control box
problems, motor problems, etc. Try to find out the answers to these questions
before you contact Kasco to narrow down the problem.
- How long does it take to trip the breaker?
- Does it always take the same amount of time to trip?
- How many times has it tripped?
- Have there been any recent electrical problems in the area?
My aerator seems to run slowly.”
This can also be a symptom of several possible problems. There could be an electrical problem where the unit is not getting the proper voltage. This could also indicate a problem with the motor of the unit, which needs to be looked at by an Authorized Repair Center. Check that the unit is receiving the proper voltage, and, if so, contact Kasco for further steps.
“My aerator hums, but will not start. When I spin the prop with a stick, it
starts up.”
(for single phase units only) This indicates a problem with the starting
capacitor. Each Kasco aerator is equipped with a starting capacitor to get the
unit going when it is first plugged in. If it is operating but not spinning
and can be started by spinning the prop with a stick, the starting capacitor
needs to be replaced by an Authorized Repair Center.
“My aerator turns itself off and back on without the timer and without
tripping the GFI breaker.”
(for single phase units only) Each Kasco unit has a thermal overload built in
that will turn the unit off when it overheats. Once the unit has cooled down,
it will start back up. If you are noticing these symptoms, the unit should be
unplugged immediately because the thermal overload will continue to turn on
and off until it burns out and damages the motor. The unit should be unplugged
and taken out of the water to find the cause of the problem. The problem could
be one of many, such as low water levels, build-up on the unit to prevent heat
dissipation, something inhibiting the free rotation of the shaft, etc. If
something is caught in the unit, or if there is buildup on the unit, remove
the debris. If caught early enough, the unit should be fine. Contact a Kasco
representative before restarting the unit.
“My aerator flow seems to fluctuate and/or be less than usual.”
This can occur because of a few different reasons. Most of the time, this
symptom is caused by the unit being clogged with debris. A mat of weeds, many
leaves, plastic bags, etc., can clog up the unit and cause it to be starved of
water. If the unit does not have the proper amount of water, the flow or
pattern will fluctuate up and down and look sporadic. If you are seeing these
symptoms, first try turning off the unit and/ or unplugging it for 10 seconds,
allowing debris to fall away. If the problem persists, unplug the unit and
clean away any debris that is clogging up the guard. Another possibility is a
chipped or damaged prop that is causing the unit to wobble and not pump
properly. When the unit is unplugged, check the prop and replace it if it is
damaged.
“The GFI breaker trips randomly and sporadically. Sometimes it is after a
few hours of operation; other times it can be days or weeks.”
This is referred to as a nuisance trip. This usually occurs where the unit is
installed a great distance from the initial electric service on the property
where the ground stake is placed. It is caused by either induced current in
the ground wire or a base voltage difference due to soil pH levels. Contact an
electrician and install a local grounding stake. This may eliminate the
induced current and any base voltage differences.
UNIT REPLACEMENT PARTS
Item | Part # | Description | Qty. |
---|---|---|---|
A | 240170 | 2400 AERATOR PROPELLER | 1 |
A | 340125 | 3400 AERATOR PROPELLER | 1 |
A | 440430 | 4400 AERATOR PROPELLER | 1 |
B | 342058 | JAM NUT (*3400A ONLY) | 1 |
C | 243475 | ZINC ASSEMBLY | 1 |
D | 990410 | FLINGER | 1 |
E | 993201 | CAGE | 1 |
F | 840543 | SERRATED FLANGE NUT | 1 |
G | 840532 | SERRATED FLANGE SCREW | 1 |
WARRANTY
Warranty Period: Models 2400A, 3400A, 3400HA, 4400A, 4400HA = 2 years
Kasco® Marine, Inc. warrants this aerator to be free from defects in material
or workmanship (except for the ropes, power cord, and propeller) under normal
use and service. The Kasco Marine, Inc. obligation under this warranty is
limited to replacing or repairing free of charge any defective part within the
warranty period. Customer shall pay shipping charges for returning the unit to
Kasco or an Authorized Repair Center.
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND
ANY OTHER OBLIGATION OR LIABILITY WHATEVER ON THE PARTv OF KASCO MARINE, INC.
AND IN NO EVENT SHALL KASCO MARINE, INC. BE LIABLE FOR ANY SPECIAL OR
CONSEQUENTIAL DAMAGES.
Warranty is void if:
- The unit is not maintained properly according to the Maintenance Recommendations supplied inthis manual.
- The unit is returned for repair without the power cord or if the unit, control box, or power cord are altered in any way from original shipment. Cuts in the power cord are not covered under warranty.
- The unit is damaged by unauthorized tampering.
- The sacrificial anode around the propeller shaft shows significant deterioration. (The anode must be inspected periodically and replaced if necessary.)
Warranty Claim Procedure:
The best method for establishing warranty period is via the original receipt.
Also, register the unit online at: www.kascomarine. com. Once the warranty
coverage has been established, the unit may be sent to any Kasco Authorized
Repair Center for evaluation and repair. Please call\Kasco Marine at
715-262-4488 prior to shipping to\
receive any updated information and/or repair form or call Kasco Marine at
715-262-4488 to locate your nearest
Authorized Repair Center. You can also email Kasco at support@kascomarine.com.
Please include the repair form received from Kasco Marine or your local
distributor with the shipment. If no repair form is available, include your
name and physical address for return delivery of the repaired unit and a
daytime phone number and/or e-mail address for correspondence regarding the
warranty claim. Any expedited shipping method for the return of the unit is at
the customer’s expense. Kasco Marine will return units repaired under warranty
at our expense via ground freight within the continental United States.
Other Repairs
Most failed equipment can be repaired at substantially lower costs than
replacement with new. Please ship according to the instructions in the
previous section.
Kasco Marine does estimates on repairs at the request of the customer. The
request for an estimate should be included in the letter that accompanies the
returned unit and must include a daytime phone number and/or e-mail address.
Estimate options are as follows:
- We will contact the customer with a total estimated cost for repairs after we have evaluated the unit but before we perform the work.
- We will repair the unit only if repair costs are under a dollar amount stated by the customer.
Example : “Please repair if total is under $150.00 before shipping charges.”
All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer.
If the customer would like the unit returned, the unit will be restored as closely as possible to the condition in which it was received and shipped at the customer’s expense for shipping and handling charges. Billing: Kasco Marine also accepts Visa and Master- Card credit card payments. Kasco Marine will call for credit card information upon completion of the estimate at the customer’s request. All other warranty and repair inquiries should be directed to Kasco Marine, Inc. at 715-262-4488 or repairs@kascomarine.com
Kasco only accepts complete assemblies for warranty repair. We must receive
the power cord and all other components with the motor as originally
assembled. THIS DOES NOT INCLUDE CONTROL PANEL, FLOAT, MOUNT, OR OTHER PARTS
THAT CAME IN ADDITION TO THE MOTOR ASSEMBLY, UNLESS SPECIFICALLY REQUESTED BY
A KASCO REPRESENTATIVE. Kasco will bill the customer to replace any missing
parts necessary for repair.
Please attach a repair form with the shipment. The repair form must include a
name, physical address (for return delivery of the repaired unit), daytime
phone number, and an e-mail address for correspondence regarding the warranty
claim. Any expedited shipping method for the return of the unit is at the
customer’s expense. Kasco
Marine will return units repaired under warranty at our expense via ground
freight within the continental United States.
CONTACT US
Kasco Marine 800 Deere Road Prescott, WI 54021
kascomarine.com
support@kascomarine.com
715.262.4488
REPAIR CONTACT FORM
- Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention.
- Unit should be cleaned before shipping.
- Kasco is NOT responsible for shipping damage accrued in return shipment.
- It is the responsibility of the customer to ship and pay freight to Kasco.
Note : Contact information should be that of the person or company to contact for repair information
Kasco Marine 800 Deere Road Prescott, WI 54021
Attn : Repairs
Note : Contact information should be that of the person or company to
contact for repair information.
Company name|
---|---
Contact name
| First name| Last name
|
Address
| Street|
City|
State|
ZIP code|
Phone number
| Primary| Alternate
|
Email address|
Preferred method of contact (circle one)| Phone Email
Purchase order number|
Additional product information| Serial Number| Cord Length
|
Information for Repair Technician
Was this unit used in a chemical treatment or wastewater application? (circle
one)|
Yes No
Additional notes
|
References
- Expert IT Training for Networking, Cyber Security and Cloud
- Aeration Systems & Decorative Fountain Displays | Kasco Marine
- Aeration Systems & Decorative Fountain Displays | Kasco Marine
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>