  • Model: 271230
  • Power Source: 1 x 3V CR2032 lithium battery (included, non-rechargeable)
  • Battery Life: Approximately 100 hours continuous use
  • Dimensions: 204x42x(h)20 mm
  • IP Rating: IP65 Splash Proof

Product Usage Instructions

Safety Instructions:

  1. Make sure the target temperature does not exceed the probe’s range to avoid damage.
  2. Do not measure live circuits with voltages exceeding 24V AC RMS or 60V DC.
  3. Keep the unit away from radio frequency electromagnetic fields.

Battery Safety Instructions:

  1. Use the provided lithium battery.
  2. Replace the battery when needed.

Main Parts of the Product:

  1. LCD Display (On/Hold)
  2. Thermocouple Probe
  3. Protection Sleeve
  4. Battery Cover

Operating Instructions:
Congratulations on your purchase! Follow these steps for optimal usage:

  1. Insert the battery into the device.
  2. Switch on the thermometer using the power button.
  3. Place the probe at the target measurement area.
  4. Read and record the temperature displayed on the LCD.
  5. After use, turn off the device and store it appropriately.

FAQ:

  • Q: How do I change the battery?
    A: To change the battery, open the battery cover, remove the old battery, and insert a new 3V CR2032 lithium battery in the correct orientation.

  • Q: Can I immerse the thermometer in water?
    A: While the thermometer is splash-proof (IP65 rated), it is not recommended to fully immerse it in water.

  • Q: How should I clean the thermometer?
    A: Use a damp cloth with mild detergent to clean the external surfaces. Do not submerge in water or use harsh chemicals.

Read user manual and keep this with the appliance.

For indoor use only.

NOTE: This manual is translated from original English manual using AI and machine translations.

Technical specifications

A 1 x 3V CR2032 lithium battery included (non-rechargeable)
B +/-0.8% of reading or 0.8°C (1.5°F) whichever is greater
C 0~50°C/ 32~122°F
D -50~350°C/ -58~662°F
E 0.1°C/0.1°F, otherwise 1°C/1°F
F TCP:100 hours continuous use
G 204x42x(h)20 mm/мм
  • A: Powered by: 1 x 3V CR2032 lithium battery included (non-rechargeable)

  • B: Accuracy: Tamb = 25°C (+/-0.8% of reading or 0.8°C (1.5°F) whichever is greater)

  • C: Operating ambient temperature

  • D: Measurement range

  • E: Resolution (-58~199.9°C/°F)

  • F: Battery life (TCP:100 hours continuous use)

  • G: Dimensions

  • The thermometer will automatically shut off if left idle for more than 15 sec.

Remark: Technical specification is subject to change without prior notification.

Special safety instructions

  • CAUTION: Please make sure the target to be measured will not exceed the temperature range of the probe to avoid permanent damage to the thermocouple probe.
  • CAUTION: To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding 24V AC RMS or 60V DC with the thermocouple probe.
  • EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

Battery Safety Instructions

  • DANGER OF EXPLOSION! Batteries must not be re-chargeable or throw in the fire or short-circuited.
  • Do not expose batteries to extreme temperatures such as from direct sunlight or fire. Do not place the product on a heating source.
  • If batteries are already leaked, remove them from the battery compartment with a clean cloth. Dispose of the batteries by the provisions. Avoid contacting the leaked battery acid.
  • CAUTION! There is a danger of explosion if the batteries are inserted incorrectly. Use only the same battery types. Do not use old and new batteries together and of different type from different manufacturer.
  • Always insert batteries in accordance (+) and (-) polarity as illustrated in the battery compartment.
  • Batteries are life-threatening if swallowed. Store all batteries out of the reach of the children. Seek medical help immediately if batteries are swallowed.
  • Do not allow children to change batteries.
  • Remove the batteries when you are not going to be using the product for a long period.

Main parts of the product

  1. LCD
  2. (On/ Hold)
  3. °C
  4. Thermocouple probe
  5. Protection Sleeve
  6. Battery Cover

* IP65 Splash Proof
Remark: The content of this manual applies for all listed items unless specified otherwise. The appearance may vary from the shown illustrations.

Operating instructions

Congratulations on the purchase of the product. We hope than you can make use of this product for a long time and that it helps you with your work. Information that are useful and important for understanding the function are highlighted in the instructions text. Powered by a replaceable lithium battery, the thermometer is a handy, temperature measurement device for a whole range of measurement and control applications.

Operating the appliance

  1. Power on: To switch the thermometer on, keep Key pressedfor approximately one second.

  2. Display LCD:
    All necessary information is displayed on an LCD. The individual symbols have the following meanings:

  3. Display for current measured values

  4. Minus sign (negative measured values)

  5. Battery status indicator

  6. – Auto shut down after 15 sec.

  7. Temperature unit

  8. Measuring temperature
    Select the required unit of measurement
    °C or °F.
    °C /°F can be changed only when “Hold” is shown.

  9. Position the tip of the thermocouple where you wish to measure the temperature and press key. Wait till the temperature has stabilized and subsequently read the value from the display. Now, the current temperature is displayed for about 4 min. If you press a second time, the word “HOLD“ appears in the LCD.

  • The last measured value is frozen and the thermometer deactivates itself automatically after about 15 seconds to save battery power.

CAUTION: The thermometer should be protected from the following:

  1. Electro Static Discharge
  2. ”Thermal shock” caused by large or abrupt ambient temperature changes – allow 30 minutes for unit to stabilize before use when exposed to “thermal shock”.
  3. Do not leave the unit on or near objects of high temperature.
  4. Keep out of reach of all children.

Cleaning & maintenance

Clean the device with a damp cloth. Do not use any solvents such as acetone as they corrode the plastic. Isopropyl alcohol may be used to disinfect. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature between –20 to +65°C (-4~149°F)

Error code identification

HENDI-271230-Fast-Response-Thermometer- \(4\)

Batteries

The thermometer incorporates visual low battery indication as follows:

Battery replacement
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with a CR2032 lithium cell. The battery is located under the twist cover at the rear of the thermometer. Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery properly and keep away from children.

Warranty

Any defect affecting the functionality of the appliance which becomes apparent within one year after purchase will be repaired by free repair or replacement provided the appliance has been used and maintained in accordance with the instructions and has not been abused or misused in any way. Your statutory rights are not affected. If the appliance is claimed under warranty, state where and when it was purchased and include proof of purchase (e.g. receipt).

In line with our policy of continuous product development we reserve the right to change the product, packaging and documentation specifications without notice.

Discarding & Environment

When decommissioning the appliance, the product must not be disposed of with other household waste. Instead, it is your responsibility to dispose to your waste equipment by handing it over to a designated collection point. Failure to follow this rule may be penalized in accordance with applicable regulations on waste disposal. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment.

For more information about where you can drop off your waste for recycling, please contact your local waste collection company. The manufacturers and importers do not take responsibility for recycling, treatment and ecological disposal, either directly or through a public system.

Please non-destructively separate spent batteries and accumulators that are not enclosed in the used equipment, as well as lamps that can be removed from the used equipment without destroying it, from the used equipment before returning it at a collection point. Unless the used equipment is separated in order to prepare it for re-use.

HENDI B.V.
Innovatielaan 6
6745 XW De Klomp, The Netherlands
Tel: +31 317 681 040
Email: info@hendi.eu

HENDI Polska Sp. z o.o.
ul. Firmowa 12
62-023 Robakowo, Poland
Tel: +48 61 658 7000
Email: info@hendi.pl

HENDI GmbH
Ehring 15
5112 Lamprechtshausen, Austria
Tel: +43 6274 200 10 0
Email: office.austria@hendi.eu

HENDI Romania S.R.L.
Str. 13 decembrie 94A, Hala 14
Brașov, 500164, Romania
Tel: +40 268 320330
Email: office@hendi.ro

PKS HENDI South East Europe SA
5 Metsovou Str.
18346 Moschato, Athens, Greece
Tel: +30 210 4839700
Email: info@pks-hendi.com

HENDI Italia S.R.L.
Via Leonardo da Vinci 4
39100 Bolzano (BZ), Italy
Tel: +39 800 727 438
Email: office.italy@hendi.eu

HENDI HK Ltd.
1201, 12/F Exchange Tower
33 Wang Chiu Road, Kowloon Bay, Hong Kong
Tel: +852 2154 2618
Email: info-hk@hendi.eu

Find HENDI on internet:
www.hendi.com
www.facebook.com/HendiToolsforChefs
https://www.linkedin.com/company/henditools-for-chefs/
www.youtube.com/HendiEquipment

Changes, printing and typesetting errors reserved.
© 2024 HENDI B.V. De Klomp – The Netherlands

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals