PREMIUM LEVELLA PRNS6070DX Single Door Merchandiser Refrigerator User Manual

June 24, 2024
PREMIUM LEVELLA

PREMIUM LEVELLA PRNS6070DX Single Door Merchandiser Refrigerator User

Manual

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-product

Specifications

  • Model: PRNS6070DX / PRNS7170DX / PRNS8570DX
  • Type: Single Door Merchandiser Refrigerator
  • Application: Commercial

Product Usage Instructions

Important Safety Instructions

Before using the product, please ensure you read and understand the important safety instructions provided in the user manual.

Transportation and Placement

Transportation: Follow the schematic diagram for space needs during transportation.

Choosing the Installation Location

  • The unit is for indoor application only.
  • Avoid placing the unit near heat sources, air streams from ventilation fans, open doors/windows, or roof-mounted ventilation systems.
  • Ensure the unit has sufficient space for proper ventilation.

Usage Guidelines

This equipment is designed for storing and displaying non-time/temperature control for safe foods, bottled, or canned products only.

Care and Maintenance

Regularly clean the interior and exterior of the refrigerator to ensure optimal performance.

Check the product rating label for electrical schematic and parameters guidance.

Important Instructions

  • Place is not intended for use by persons (including children) whose physical, sensory, or mental capabilities may be different or reduced, or who lack experience or knowledge unless such persons receive supervision or training to operate the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance.

  • Cleaning and

  • ease follow local regulations regarding the disposal of the appliance for its flammable blowing gas.
    Before you scrap the appliance, please take off the doors to prevent children from being trapped.

  • WARNING: Keep clear of obstructions to all ventilation openings in the appliance enclosure or in the structure for building-in.

  • WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.

  • WARNING: Do not damage the refrigerant circuit.

  • WARNING: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.

  • The electrical schematic and parameters shall be based on the product rating label.

  • The product may be improved without notice.

  • If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

  • Reducing the door opening time and frequency is good for keeping a cold temperature inside the refrigerator.

  • Never block the air suction and outlet to keep the air circulation and refrigeration capability.

  • Do not overfill, as this will influence the cooling effect.

  • Adjust the rack height for proper food storage.

  • Cool hot foods down to room temperature before you put them into the refrigerator.

  • Try to reduce the opening times to keep the refrigerator inside cold in case the power is cut off.

  • Never touch the compressor to avoid scalding.

  • This appliance user maintenance shall not be done by children without supervision.

  • Do not store explosive substances such as aerosol cans with flammable propellant in this appliance. During normal operation, the emission noise level does not exceed 68dB(A).

  • With the climate class is 4, the appliance is suggested to be used at 16℃-32℃ ambient temperature.

  • Please discard according to local regulations regarding disposal of the appliance for its flammable gas. Before you scrap the appliance, please take off the doors to prevent children from being trapped.

  • Warning: the appliance must be installed under national wiring regulations.

  • This appliance is to be installed under the Safety Standard for Refrigeration Systems, ANSI/ASHRAE 15.
    Warning: Risk of fire / flammable materials, take care to avoid causing a fire by igniting flammable material.
    Notice: Any person who is involved in working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry- accredited assessment authority, which authorizes their competence to handle refrigerants safely under an industry-recognized assessment specification.

  • Notice: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repairs requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

  • Notice: Parts shall be replaced with like components to minimize the risk of possible ignition due to incorrect parts.

  • WARNING- The appliance shall be installed in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).

  • Do not pierce or burn.

  • Be aware that refrigerants may not contain an odor.

  • Warning: The appliance shall be installed in a well-ventilated area where the room size corresponds to the room area as specified for operation.

  • Warning: The appliance shall be installed to prevent mechanical damage from occurring.

  • Check that the cable will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also consider the effects of aging or continual vibration from sources such as compressors or fans.

  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

  • Before carrying out the decommissioning procedure, the technician must be completely familiar with the equipment and all its details. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-using recovered refrigerant. It is essential that electrical power is
    available before the task commences.

  • When removing refrigerants from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.

  • The recovery equipment shall be in good working order with a set of instructions concerning the
    equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, FLAMMABLE REFRIGERANTS

  • The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.

  • The appliance shall not be installed in public corridors or lobbies

Dear Customer

Dear users (customer), this manual contains the product’s basic knowledge, use instructions, fault diagnosis and basic troubleshooting methods. In order to better understand and use this product, please take good care of this manual and read it carefully.
This equipment is intended for the storage and display of non-time/temperature control for safety foods bottled or canned products only.

Important safety instructions

  1. The range of operating voltage is 97V~130V. To avoid damaging the electrical performance of the compressor, please install with a voltage stabilizer appliance of power not less than 500W, to protect the cooler when the voltage is lower than 97V or higher than 130V.

  2. An exclusive single-phase socket must be used. It should be reliably connected to a grounding wire. Caution: The grounding wire is not allowed to connect to a water pipe or a gas pipe.

  3. Strong base, acid, organic solvents, and corrosive goods that are easy to pollute the food are prohibited from being stored in the cooler. They can cause corrosiveness or accidents.

  4. Don’t raise the cooler or the shell of the electric parts, or it will cause a decline in insulation and cause corrosion.

  5. When the cooler will be not be used for a long time, disconnect the power and clean it. Please examine the circuit to see whether it is ok before reuse.

  6. If the supply cord is damaged, it must be replaced by a special cord or assembly
    available from the manufacturer or its service agent.

  7. The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts.

  8. The A-weighted emission sound pressure level is below 70Db(A).

  9. Do not store explosive substances such as aerosol cans with flammable propellants inside the appliance.

  10. Flammable blowing gas in the cooler should be handled according to local regulations.
    Before you scrap the appliance, please take off the doors to prevent children from being trapped.

Caution

  1. Risk of fire / flammable materials, take care to avoid causing a fire by igniting flammable material.
  2. Keep clear of obstruction of all ventilation openings in the appliance enclosure or in the structure for building-in.
  3. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  4. Do not damage the refrigerant circuit.
  5. Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
  6. The ambient temperature and humidity conditions of the cooler climate class follow the table below:

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-fig-1

NOTE: the water vapor mass in dry air is one of the main points influencing the performance and the energy consumption of the coolers. Therefore, the order of the climate class in the table is based on the water vapor mass column.

Transportation and Placement

Transportation

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-fig-2

  1. Take out packing materials and clean all the cabinets using warm water with 5% neutral soap and then dry it with a soft cloth; for the glass parts only use specific products, avoiding the use of water which can leave limestone residues on the glass.
  2. Keep a distance of at least 10 cm from the wall. Please level the unit by settling the adjustable feet.
  3. The cabinet must be installed on a perfectly even surface, far away from any heat source including sun rays.
  4. Do not install the unit in open places and do not expose it to rain.

Choosing the installation location

The unit is for indoor application only.
Because the unit has a glass door, its performance is highly influenced by environmental conditions. To minimize the environmental effects on the unit’s performance, the following are recommended:

  • The unit is not to be placed near any kind of heat source.
  • The unit is not to be placed near or inside air streams produced by ventilation fans, open doors and/ or windows.
  • The unit is not to be situated under a roof-mounted ventilation system.
  • The unit should have sufficient space to ‘breathe’ (always use the rear space to ensure minimum clearance).
  • The unit should not be placed under direct sunlight.
  • Keep all ventilation openings in the appliance enclosure or in the structure clear of obstruction.
  • In order to reduce fire hazards, the installation of this appliance must be carried out only by a suitably qualified person.

Leveling the unit

Place the unit at the chosen location. Using a spirit level, check whether the unit is leveled in both directions.
The spirit level can be placed on one of the shelves.
The unit must be leveled during operation to avoid possible ice formation on the evaporator’s fins due to insufficient drainage of the condensation.
Tilt the unit by a 2° angle for easy closing of the door and drain.

  • Do not insert cream or spray bottles inside the cooler.
  • Do not store explosive substances such as aerosol cans with flammable propellants in the cooler.

Product Features

  1. It uses a quality, effective, and hermetic compressor with broad range of starting voltage, suitable ambient temperature: not higher than 40℃, and reasonable matching of the cooler system that guarantees its powerful refrigerating ability and energy saving.
  2. Goods stored can be displayed clearly through the door made of luxurious hollow glass.
  3. The thermal insulation layer of the cooler made from hard polyurethane foamed plastics makes it light and has a good ability to keep the contents cold.

Details of Product

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-fig-3

Note: Due to technological innovations, the descriptions of the product in this manual may not be completely consistent with your upright showcase. Details are in accordance with the material item.

Production Dimensions

Model PRNS6070DX PRNS7l70DX PRNS8570DX
Dimension(W×D×H/inch) 2l.l×2l.l×50 2l.l×2l.l×56.5 2l.l×2l.l×65.7
Net Capacity (CU. FT) 6.0 7.l 8.5
Temperature (℉) 32~50 32~50 32~50
Control System Mechanical Mechanical Mechanical
Lock & Light Yes Yes Yes
Refrigerant R600a R600a R600a
Climate Type 3,4,5 3,4,5 3,4,5

The Maximum Loading of Each

Type Of Shelf(LB)

| 7l.7| 7l.7| 7l.7

Operation of the Temperature control knob

The temperature inside the cabinet can be controlled with the temperature control knob. 2. The knob should be kept upright normally to adjust the temperature.

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-fig-5

Note: The cooler should not work more than 24 hours in coldest function 7, please turn the knob back to 4 in time.

Electrical Connection

Electronic diagram

PREMIUM-LEVELLA-PRNS6070DX-Single-Door-Merchandiser-Refrigerator-User-
Manual-fig-6

WARNING

  1. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord supplied.
    This appliance is not designed to be used with an inverter.
    The cord should be secured behind the appliance and not left exposed or dangling to prevent accidental injury.

  2. Never unplug the cooler by pulling the power cord. Always grip the plug firmly and pull straight out from the receptacle.

  3. Do not use an extension cord with this appliance. If the power cord is too short, have a qualified electrician or service technician install an outlet near the appliance. Use of an extension cord can negatively affect the performance of the unit.

  4.  Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is damaged, have it replaced by an authorized service center.

Safety Warnings

  • Warning! Do not damage the cooling fluid circuit.
  • Warning! Do not damage the walls of the machine: the cooling fluid circuit may be damaged.
  • Warning! Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
  • Warning! The equipment must not be used by persons (including children) whose physical, sensorial, or mental capacities are reduced, or who lack experience and know-how, unless
    they have been provided, by means of a person responsible for their safety, with suitable monitoring or instructions about the use of the equipment. Children must be monitored to ensure they do not play with the equipment.

Use warnings

  1. Unpack all packages before using the cooler. Do not tilt it over more than 60°, while moving it.
  2. In its initial operation, the cooler should run emptily for about two hours before storing food in it. 3. The thermostat can adjust the temperature inside the cooler. When you turn the knob
  3. clockwise, the bigger the number, the lower the temperature. Generally, the positions ‘3-4’ are suitable for regular operation. The ’6’ position has the appliance operating continually.
  4. To save energy, the door should not be opened too frequently or left open for a long time.
  5. The surface and the inside of the cooler should be dry and clean. Long-term moisture will cause the cooler to slowly rust. (There will be some stains on the surface.)
  6. Periodical cleaning is suggested. Generally, cleaning the appliance once every 30-45 days is the best. When cleaning, it is best to wipe the inside and the surface of the cooler with a soft cloth with neutral soap or detergent.
  7. Caution: To ensure safety, the power plug must be pulled out before cleaning.

Cleaning the unit

For cleaning the unit’s internal plastic parts, use a light solution of soap and water. Do not apply hard chemical detergents on the plastics as they may lose their shine or even get deformed.
The same applies to the external metallic surfaces. The use of hard chemicals could harm the painting of the metallic surfaces, affecting the sanitary protection of the unit.

Troubleshooting

Please refer to the below troubleshooting lists to solve any minor problems that may occur during operations.

Trouble| Reason| Check| Solution| Remark|
---|---|---|---|---|---

Lamp not lighting

|

No voltage

| Fuse breaking off| Check fuse| Change fuse|

Ask a professional to service.

|
Poor connection between the plug and

socket

| The connection is loose or not|

Repair or change socket

|

Have voltage

| lamp has poor contact or is worn down| Check the circuit and lamp| Tighten the connection or change a new lamp|

Ask a professional to service.

|
Lamp switch has poor contact| Check the switch| Tighten the connection or change a new switch|

Condenser fan

Not running

| Compressor works| Condenser fan broken down|

Remove condenser fan

|

Change condenser fan

|

Compressor does not work

| Thermostat is not set to the work position| Check the position of the thermostat knob| Turn the thermostat knob to the operating

position

|
Thermostat terminal is not connected

properly

| Check the thermostat terminal|

Reconnect the terminal

|
The thermostat is worn down.| Check the thermostat| Change the thermostat| Ask a professional to

service.

|

Continuous operating

|

Temperature is too high inside of the cabinet

| Opening the door too frequently|

I

| Open the door as little as possible|

Ask a professional to service.

|

Too much storage

| The circulation of cooling air has been

affected

| Take out part of the storage|
Leakage of refrigerant.| I| Call at a qualified service center|
Temperature is too low

inside the cabinet.

|

Thermostat does not work properly

|

Check the thermostat

|

Change the thermostat

|
Ask a professional to service.|

Noise

|

Cooler isn’t placed levelly

| Check if the four wheels adjusted to the

same level and touching the ground

|

Adjust the wheels

|

Ask a professional to service

|
Fixing screws of compressor or condenser are loose| Screws fixed tightly or not| Tighten the screws| Ask a professional to

service.

|

Compressor or fan defective

| Check the Compressor or fan| Ask help of professional to repair.| Ask help of professional to

repair.

|
Condenser fan is working, but the compressor does not operate| The plug of starter or heat relay is

loose

| Check the starter and

heat relay

| Install the starter or

heat relay

| Ask a professional

to service.

|

Compressor defective

| Check the resistance of compressor CSM

terminal

|

Change new compressor

|

Ask a professional to service.

|
Voltage is lower than 97V or higher than 130V| Check the input Voltage| Use a voltage stabilizer|
Evaporator fan

Not running

| Fan switch defective| Check the resistance of switch| Change the switch|

Ask a professional to service

|
Fan switch terminal is not connected properly| Check the circuit of the fan switch| Connect the switch

terminal or change a new terminal

|

Notice: The following are not trouble but common phenomenon:

  1. Sound, the refrigerant flows inside the cooler.
  2. Compressor and condenser become hot.
  3. If the ambient humidity is high, there may be dewdrops on the surface, please use a soft and dry cloth to clean in time.

FAQ

Q: Can I use this refrigerator for storing perishable items?

A: No, this refrigerator is intended for non-time/temperature control for safety foods, bottled, or canned products only.

Q: How should I dispose of the appliance?

A: Follow local regulations regarding disposal of the appliances with flammable blowing gas. Remove doors before disposal to prevent accidents.

Q: What should I do if the supply cord is damaged?

A: If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PREMIUM LEVELLA User Manuals

Related Manuals