Rinnai REU-A1620WG-ZK Infinity Graphite Range Owner’s Manual
- June 24, 2024
- Rinnai
Table of Contents
Rinnai REU-A1620WG-ZK Infinity Graphite Range
Rinnai INFINITY Graphite range specification
Description
Designed and made in Japan, the Rinnai INFINITY Graphite units are external
continuous-flow gas hot water heaters with inbuilt frost protection and status
monitors. They have electronic ignition and require electricity to operate.
They are factory-set to deliver water at 50 °C.
Scope of use
Suitable for RESIDENTIAL external applications only. To be externally mounted
on an outside wall and located as close as possible to the most frequently
used hot water outlets to reduce the delay for hot water delivery. They are
not suitable as a spa or swimming pool heater or for hydronic applications.
Hard or acidic water will need to be treated to use this product.
A16 ext | A26 ext | EF26 ext | |
---|---|---|---|
REU number | REU-A1620WG-ZK(B) | REU-A2626WG-ZK(B) | REU-E2626W-ZK(B) |
Code Natural Gas | INFA16GN | INFA26GN | INFEF26GN |
Code LPG | INFA16GL | INFA26GL | INFEF26GL |
Colour | Graphite | Graphite | Graphite |
Input | 16.3-124 MJ/h | 16.3-199 MJ/h | 16.3-175 MJ/h |
Output | 27.8 kW | 44.5 kW | 44.5 kW |
Thermal efficiency | 80% | 80% | 92% |
Capacity @ 25 ° rise | 16 L/min | 26 L/min | 26 L/min |
Exhaust system | Forced flue | Forced flue | Forced flue |
Ignition system | Direct electronic ignition | Direct electronic ignition |
Direct electronic ignition
Line pressures| NG – 1.13kPa, LPG – 2.75 kPa
Line pressure maximum| 3.5 kPa (maximum standing pressure under abnormal
intermittent conditions is
5.0 kPa). In the case of commercial metering, (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming pressure down.
Ingress protection rating| IPX5| IPX5| IPX5
Power consumption| Normal 47 W, automatic frost protection 68 W| Normal
66 W, automatic frost protection 68 W| Normal 63 W, automatic frost protection
92 W
Noise level (1 m away)| 50 dB(A), some people are susceptible to low
level noise. This needs to be considered if locating near a bedroom.
Safety devices| Flame failure, boil-dry protection, overheat protection,
fusible link, pressure relief valve, and combustion fan RPM check.
Water supply| Nominal operating pressure: 200-1000 kPa.
Minimum operating water flow will depend on setpoint and inlet temp.
Please note : If the water inlet pressure drops below the minimum value, operation of the INFINITY is not guaranteed.
Weight| 13 kg| 15 kg| 18 kg
Dimensions
Rinnai INFINITY Graphite accessories
CONTROLLERS
The maximum number of controllers that can be fitted is four.
Part number| Description
MC601A| Compact controller
BC100V1Z| Bathroom Deluxe controller
MC100V1Z| Kitchen Deluxe controller
PIPE COVER
R1385G| Rinnai INF pipe cover A16 / A26 graphite
R1416G| Rinnai INF pipe cover EF26 graphite
RECESS BOX
R1405G| Rinnai INF recess box A16 / A26 graphite
R1407G| Rinnai INF recess box EF26 graphite
SECURITY BRACKET
Please note : The security bracket is powder coated white, it is not
graphite. Compatible for all three models.
ACC1395| Rinnai INFINITY security bracket
FLUE DIVERTERS (not graphite in colour)
FDU16| Rinnai INF A16 upwards flue diverter
FDU24| Rinnai INF A26 upwards flue diverter
FDS16A| Rinnai INF A16 sideways flue diverter
FDS24| Rinnai INF A26 sideways flue diverter
FDS26E| Rinnai INF EF26 sideways flue diverter
There is no upwards flue diverter available for the EF26
Positioning: General flue terminal clearances
The following has been adapted for Rinnai INFINITY water heaters from AS/NZS
5601 6.9.3 Location of flue terminals around the perimeter of a building of
structure. Always reference the latest version of the standard for the most
up-to-date information.
Ref. | Item | Minimum clearances – fan assisted (mm) |
---|---|---|
a | Below eaves, balconies and other projections | 300 |
b | From the ground, above a balcony or other surface1 |
Please note : Rinnai recommends 1500 mm to give enough clearance for the pipe work, and to safely expel flue gases
| 300
c| From a return wall or external corner1| 300
d| From a gas meter (M)2| 1000
(see Clause 5.11.5.9 for vent terminal location of regulator)
(see Table 6.9.6 for New Zealand requirements)
e| From an electricity meter or fuse box (P)2,3| 500
f| From a drain pipe or soil pipe| 75
g| Horizontally from any building1 structure or obstruction facing a flue
terminal| 500
h| From any other flue terminal, flue cowl , or combustion air intake1|
300
j| Horizontally from an openable window, door, non-mechanical air inlet,
or any other opening into a building with the exception of sub-floor
ventilation:
Appliances up to 150 MJ/h1 input| 300
Appliances over 150 MJ/h input up to 200 MJ/h1| 300
All fan-assisted appliances , in the direction of discharge| 1500
k| From a mechanical air inlet, including a spa blower| 1000
n| Vertically below an openable window, non-mechanical air inlet, sub-
floor ventilation, or any other opening into a building with the exception of
weep holes:
For appliances over 150 MJ/h input| 1500
1 Unless appliance is certified for closer installations.
2 Minimum clearances d and e also apply to any combustion air intake openings of appliances.
3 Prohibited area below the electricity meter or fuse box extends to ground level.
-
NOTE 1 : Where dimensions c, j, or k cannot be achieved, an equivalent horizontal distance, measured diagonally from the nearest discharge point of the terminal to the opening, may be deemed by the Technical Regulator to comply.
-
NOTE 2 : See Clause 6.9.4 for restrictions on a flue terminal under a covered area.
-
NOTE 3 : A flue terminal is considered to be a source of ignition. AS/NZS 1596 specifies the minimum clearances required from a flue terminal to an LP Gas Cylinder (see Figure 1.5(A), Appendix I).
-
NOTE 4 : For minimum clearances not addressed above, acceptance should be obtained from the Technical Regulator.
-
NOTE 5 : Contact the appliance manufacturer if in doubt that the minimum clearances will provide adequate thermal protection of surfaces adjacent to the flue terminal. Additional
measures may be required. -