TOA DA-250D CE301 Dual Power Amplifiers Instruction Manual

June 4, 2024
TOA

OPERATING INSTRUCTIONS
DUAL POWER AMPLIFIERS
DA-250D CE301, DA-250D CE-GB, DA-250D CE-AU
DA-250DH CE301, DA-250DH CE-GB, DA-250DH CE-AU

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
Thank you for purchasing TOA’s Dual Power Amplifier.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

SAFETY PRECAUTIONS

  • Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
  • Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.
  • After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.

WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.
CAUTION Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.

WARNING
When Installing the Unit

  • Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.
  • Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.
  • Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects — including the unit itself — on the power cord, as doing so may result in fire or electric shock.
  • Be sure to replace the unit’s terminal cover after connection completion. Because the voltage of up to 100 V is applied to the high impedance speaker terminals, never touch these terminals to avoid electric shock. (DA-250DH only)
  • External wiring connected to the terminals marked with requires installation by an instructed person. (DA-250DH only)
  • The apparatus shall be connected to a mains socket outlet with a protective earthing connection.

When the Unit is in Use

  • Should the following irregularity be found during use, immediately turn off this unit’s power switch, disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock.
    • If you detect smoke or a strange smell coming from the unit.
    • If water or any metallic object gets into the unit
    • If the unit falls, or the unit case breaks
    • If the power supply cord is damaged (exposure of the core, disconnection, etc.)
    • If it is malfunctioning (no tone sounds.)
  • To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing such as modification inside the unit to qualified service personnel.
  • Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock.
  • Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit’s cover, as this may result in fire or electric shock.
  • Do not touch a plug during thunder and lightning, as this may result in electric shock.

CAUTION
When Installing the Unit

  • Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.
  • When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.
  • When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.
  • Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty  smoke or steam as doing otherwise may result in fire or electric shock.
  • To avoid electric shocks, be sure to first turn off this unit’s power switch when connecting speakers.
  • The unit is designed exclusively to be mounted in an equipment rack. Be sure to follow the instructions below when rack-mounting the unit. Failure to do so may cause a fire or personal injury.
    • Install the equipment rack on a stable, hard floor. Fix it with anchor bolts or take other arrangements to prevent it from falling down.
    • The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks.
    • When installing the unit in a rack other than that of TOA, be sure to use the screws with a diameter of over 5 mm and length of over 12 mm to mount the unit.
    • When connecting the unit’s power cord to an AC outlet, use the AC outlet with current capacity allowable to the unit.
  • Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.
  • Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan
  • Apparatet må tilkoples jordet stikkontakt
  • Apparaten skall anslutas till jordat uttag

When the Unit is in Use

  • Make sure to set all input level controls to (infinity) position before power is switched on. Loud noise produced when power is switched on with any of those controls set to the position other than position can impair hearing.
  • Do not operate the unit for an extended period of time with the sound distorting. Doing so may cause the connected speakers to heat, resulting in a fire.
  • Contact your TOA dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result.
  • If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely.
  • Turn off this unit’s power switch, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.

The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Warning: Operation of this equipment in a residential environment could cause radio interference.

GENERAL DESCRIPTION

TOA’s DA-250D and DA-250DH Dual Power Amplifiers feature high power handling capabilities and durability. The DA-250D is configured with 250 W x 2 channels (4 output) and 170 W x 2 channels (8 output), and the DA-250DH features a 250 W x 2 channels (100 V line, 40 output) configuration. Besides, the DA-250D’s output is made available for bridge connection, allowing it to be used as a 500 W (8 ) monaural amplifier. DA-250DH can be electrically isolated from the high-impedance speaker system by attaching the MT-251H Output transformer (option). Their wide range of applications include stores and permanent sound systems.

FEATURES

  • 1U rack mounting size*.
  • Low power consumption and light weight.
  • An input signal to Channel 1 can be routed to both channels 1 and 2, and the output level adjusted using the input level control for each channel.
  • Electronically-balanced inputs.
  • Input terminals employ removable terminal blocks and XLR type connectors to provide maximum connection ease.
  • Equipped with the LED indicators that show the input/output status, etc.
  • Built-in protection circuitry disconnects the power amplifier’s output from the load when a short circuit, overload, or unusual temperature rise occurs.
  • 1U size = 44.5 mm (reference size)

HANDLING PRECAUTIONS

  • Keep the input cable away from the output cable. If installed close to each other, oscillation could occur.
  • To avoid unit failures, never connect outputs of two or more channels in parallel.
  • Only connect speakers with an impedance equal to or greater than those specified. Connecting speakers with a smaller impedance than specified could cause damage to the unit.
  • Install the unit in locations where the temperature is between ­10 and +40°C and the moisture is less than 90%RH (no dew condensation must be formed).
  • To clean, be sure to first turn off this unit’s power switch, then wipe with a dry cloth. When the unit gets very dirty, use a cloth damped in a neutral cleanser. Never use benzene, thinner, alcohol, or chemically-treated cleaning cloth because such volatile liquids could deform or discolor the unit.
  • The fan is a consumable product. As a guideline, we recommend that it be replaced with a new one when its total operating time reaches approximately 20000 hours (when used in ambient temperatures of approximately 25°C).

Note: The above figure is simply a guideline, and does not guarantee the fan’s operating life. Since broadcasts from the digital power amplifier could be disabled if the fan malfunctions, the fan requires regular inspection and maintenance. For maintenance service, please contact the dealer from whom the digital amplifier was purchased.

INSTALLATION PRECAUTIONS

CAUTION

The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks. When installing the unit in a rack other than that of TOA, be sure to use the screws with a diameter of over 5 mm and length of over 12 mm to mount the unit. Failure to do so may cause personal injury.

  • The supplied power supply cord is designed for exclusive use with this unit. Never use it with other equipment.

  • When mounting the unit in the rack, also mount a Perforated Panel larger than 1U in size*:
    (1) at the top and the bottom of the rack, and
    (2) above and below every 5 units.

  • Robust structure is one of the unit’s main features. However, if the strength is particularly needed when installing the unit in the rack, use a supporting runner for the safety purposes.

  • 1U size = 44.5 mm (reference size)

NOMENCLATURE AND FUNCTIONS

[Front]

  1. Power switch [ ON / OFF]
    Turning this switch on causes the amplifier to function, and turning it off causes the amplifier to cease function.
    Note: The unit is not completely disconnected from the power supply even if this Power switch is turned off.

  2. Power indicator [POWER]
    Lights blue when the Power switch (1) is turned on.

  3. Input level controls [CH 1 (BRIDGE), CH 2]
    Adjust the input level of each channel. Turn the control clockwise to increase the input level and counterclockwise to decrease the level.
    When a bridge connection is made (DA-250D only)
    When Channels 1 and 2 are bridge-connected (BRIDGE ON/OFF switch (9) is set to ON), the CH 1/BRIDGE level control adjusts the input levels of Channels 1 and

  4. In this event, the CH 2 level control cannot be used.

  5. Ventilation panel (Air Vent)
    A filter is located inside the ventilation panel.

  6. Indicators [INPUT, OUTPUT, PEAK, PROTECT]
    The indicators are as follows from left to right:
    • Input indicator [INPUT]
    Lights green regardless of the input level control setting when an input signal level exceeds about ­20 dB.
    • Output indicator [OUTPUT]
    Lights yellow when an output level exceeds about 1 W at an 8 load (DA-250D) or 40 load (DA250DH).
    • Peak indicator [PEAK]
    Lights red when an output signal clips (distortion occurs).
    Note
    When the Peak indicator lights, turn the input level control (3) counterclockwise until its light extinguishes or decrease the input signal level of the connected external device. Operating the unit while the Peak indicator remains lit may cause the protection circuitry to be activated.
    • Protection indicator [PROTECT]
    Lights red when the protection circuitry is activated. (See p. 12; Protection Operation List.) When the power is switched on, this indicator lights for about 2 seconds and then extinguishes.
    [Rear]

  7. AC inlet
    Connect the supplied power cord to this inlet. The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible.

  8. Functional ground terminal [SIGNAL GND]
    Hum noise may be generated when external equipment is connected to the unit. Connecting this terminal to the functional ground terminal of the external equipment may reduce the hum noise.
    Note This terminal is not for protective earth.

  9. Speaker output terminals (with a terminal cover) [OUTPUTS (DA-250D), OUTPUTS 100V (DA-250DH)]
    Connect speaker cables to these terminals.

  10. BRIDGE ON/OFF switch (DA-250D only) [BRIDGE, ON / OFF]
    Used when bridge-connecting the unit’s Channels 1 and 2. (See p. 9 ; Settings and Connections.)
    2-channel output mode Set BRIDGE switch to OFF. (factory-preset)
    1-channel output mode Set BRIDGE switch to ON.
    Note Be sure to first turn off the Power switch (1) when changing these switch settings.

  11. CH 1 mode ON/OFF switch [PARALLEL, ON / OFF]
    Setting this switch to ON transmits the Channel 1 input signal to both channels 1 and 2. (PARALLEL mode) Note that output signal levels can be individually adjusted with each channel’s Input level control (3). Setting this switch to OFF (factory-preset) transmits each channel’s input signal to each corresponding channel. (STEREO mode)
    Note Be sure to first turn off the Power switch (1) when changing this switch setting.

  12. Input terminals [INPUTS]
    Electronically-balanced input terminals. Each removable terminal block (3 pins) is internally connected in parallel to the corresponding XLR type connector.
    • Removable terminal block (3 pins)
    H: Hot, C: Cold, E: Earth
    • XLR type male connector (XLR-3-31 equivalent)
    Pin 1: Earth, Pin 2: Hot, Pin 3: Cold
    Caution when using an XLR type plug
    If a straight plug hits the rack’s rear cover or wall behind the rack when it is used for connection, use the L-shaped plug instead.

SETTINGS AND CONNECTIONS

Note: The figure shows the DA-250D.

Step 1. Turn off this unit’s Power switch.
Step 2. Set the BRIDGE ON/OFF switch (DA-250D only) and CH 1 mode ON/OFF switch.
Step 3. Connect the sound source equipment to the Input terminals. Note: Refer to p. 11 for the removable terminal plug connection.
Step 4. Connect speakers to the Speaker output terminals.

4-1. Unscrew the output terminal cover.
4-2. Strip 10 mm of insulative jacket from the end of the speaker cable, as shown in the figure at right.
4-3. Connect speaker cables to the output terminals.
4-4. Replace the output terminal cover in place.

WARNING Be sure to replace the unit’s terminal cover after connection completion. Because high voltage is generated at the speaker output terminals, never touch these terminals to avoid electric shock. (DA-250DH only)

Switch Settings and Speaker Connections
When using the DA-250D
When using the DA-250DH

REMOVABLE TERMINAL PLUG CONNECTION

Cautions

  • Be sure to use shielded cables for audio signal lines.
  • Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
  • Use cables of AWG 12 ­ 24.

Cable end treatment

Connector connections
Step 1. Loosen the terminal screw, then insert the cable.
Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.)

Tip Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm in width

PROTECTION OPERATION LIST

Failure Protection Operation Indicator Remedy Recovery
Overcurrent due to overload Current limiter activated when impedance drops
below the specified value. Peak indicator lights. Remove overload.

Connecting a correct load automatically restores normal operation.
Short circuit| Current limiter activated. Load is disconnected.| Protection indicator lights.| Check speakers and
lines for short circuit.| Turn off this unit’s Power switch. Correct the load, then turn on the power.
Temperature rise at power amp. heat sink
(over 100°C)| Load disconnected.| Protection indicator lights.| Check the unit for correct ventilation and overload.| Operation automatically returns to normal when the temperature decreases.
Temperature rise inside the unit (over 80°C)| Built-in amplifier unit that caused the failure halted.| Four indicators of the corresponding channel extinguish.
Abnormal DC voltage output| Load disconnected.| Protection indicator lights.| Contact the TOA dealer where the unit was purchased.

TAMPER-PROOF CAP ATTACHMENT

To protect the input level control from accidental operation, it is recommended to replace the control knob with the supplied tamper-proof cap as illustrated.

DIMENSIONAL DIAGRAM

LOCK DIAGRAMS

DA-250D
DA-250DH

SPECIFICATIONS

DA-250D CE301, DA-250D CE-GB, DA-250D CE-AU
Power Source 220 — 240 V AC, 50/60 Hz
Amplification system Class D
Power Consumption 150 W (based on EN standards)

620 W (rated output 4 Ω x 2)
400 W (rated output 8 Ω x 2)
Input| 2 circuits, +4 dB* (1.23 V, input level control in maximum position), 10 kΩ, electronically-balanced, removable terminal block (3 pins), XLR-3-31 type connector CH 1 mode ON/OFF switch (ON: PARALLEL, OFF: STEREO)
Rated Output| 2 channels: 250 W x 2 (4 Ω), 170 W x 2 (8 Ω)
1 channel (BRIDGE): 500 W (8 Ω)
M4 screw terminal, distance between barriers: 8.8 mm
Frequency Response| 20 Hz— 20 kHz (+1 dB)
Total Harmonic Distortion| 0.1% (1 kHz), 0.3% (20 Hz— 20 kHz)
Protection Circuit| Protection against excessive current flow due to overload, short circuit, unusual DC voltage output, temperature rise at power amp. heat sink (100°C or more), temperature rise inside the unit (80°C or more)
S/N Ratio| 100 dB (A-weighted)
Crosstalk| 70 dB (A-weighted)
LED Indicator| Power (blue) x 1, Input (green) x 2, Output (yellow) x 2, Peak (red) x 2, Protect (red) x 2
Cooling| Forced air cooling
Operating Temperature| —10 to +40°C
Operating Humidity| 90%RH or less (no condensation)
Finish| Panel: Aluminum, black, alumite Case: Plated steel sheet
Dimensions| 482. (w) x 44 (h) x 401.8 (d) mm
Weight| 5.3 kg

  • 0 dB = 0.775 V

Note: The design and specifications are subject to change without notice for improvement.

  • Accessories
    Power cord (2 m) ………………………………………………………. 1
    Removable terminal plug (3 pins) ……………………………… 2
    Rack mounting screw (with plain washer) 5 x 12 ………. 4
    Tamper-proof cap …………………………………………………….. 2
DA-250DH CE301, DA-250DH CE-GB, DA-250DH CE-AU
Power Source 220 — 240 V AC, 50/60 Hz
Amplification system Class D
Power Consumption 150 W (based on EN standards)

580 W (rated output 100 V line, 40 Ω x 2)
Input| 2 circuits, +4 dB* (1.23 V, input level control in maximum position), 10 kΩ, electronically-balanced, removable terminal block (3 pins), XLR-3-31 type connector CH 1 mode ON/OFF switch (ON: PARALLEL, OFF: STEREO)
Rated Output| 2 channels: 250 W x 2 (100 V line, 40 Ω)
M4 screw terminal, distance between barriers: 8.8 mm
Frequency Response| 50 Hz— 20 kHz (-3 dB, +1 dB)
Total Harmonic Distortion| 0.1% (1 kHz), 0.3% (100 Hz— 20 kHz)
Protection Circuit| Protection against excessive current flow due to overload, short circuit, unusual DC voltage output, temperature rise at power amp. heat sink (100°C or more), temperature rise inside the unit (80°C or more)
S/N Ratio| 100 dB (A-weighted)
Crosstalk| 70 dB (A-weighted)
LED Indicator| Power (blue) x 1, Input (green) x 2, Output (yellow) x 2, Peak (red) x 2, Protect (red) x 2
Cooling| Forced air cooling
Operating Temperature| —10 to +40°C
Operating Humidity| 90%RH or less (no condensation)
Finish| Panel: Aluminum, black, alumite Case: Plated steel sheet
Dimensions| 482. (w) x 44 (h) x 401.8 (d) mm
Weight| 5.3 kg

  • 0 dB = 0.775 V

Note: The design and specifications are subject to change without notice for improvement.

  • Accessories
    Power cord (2 m) …………………………………………………………. 1
    Removable terminal plug (3 pins) ………………………………… 2
    Rack mounting screw (with plain washer) 5 x 12 …………. 4
    Tamper-proof cap ……………………………………………………….. 2

  • Optional product
    Matching transformer : MT-251H

Traceability Information for Europe

Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan| Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg, Germany
---|---

TOA Corporation
URL: https://www.toa.jp/
133-03-00013-01

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals