Lierda SB16 Series 2 Wire Irrigation Controller User Manual
- June 24, 2024
- lierda
Table of Contents
- Legal Notices
- Document revision history
- Safety instructions
- Applicable modules Options
- Introduction
- Product Overview
- Application interface
- Specification
- Application Notes
- Mechanical dimensions
- Production and Packaging Information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Lierda SB16 Series
Hardware Design Manual
Legal Notices
By receiving this document from Lierda Technology Group Corporation
(hereinafter referred to as “Lierda”), you agree to the following terms. If
you do not agree to the following terms, please stop using this document.
This document is copyrighted by Toledo Technology Group Corporation, with any
rights not expressly granted in this document reserved. The document contains
proprietary information of Lierda. This document and any images, forms, data
and other information contained in this document may not be reproduced,
transmitted, distributed, used or disclosed by any entity or individual
without the prior written permission of Lierda.
This product complies with the design requirements regarding environmental
protection and personal safety. The storage, use and disposal of the product
should be carried out in accordance with the requirements of the product
manual, the relevant contract or the relevant laws and regulations.
The Company reserves the right to make changes and improvements to the
products described in this manual without prior notice; it also reserves the
right to revise or withdraw this manual at any time.
Document revision history
Document version | Date of change | proposer | auditor | Changes |
---|
Safety instructions
It is the user’s responsibility to follow the relevant regulations of other
countries and the specific environmental regulations for the use of wireless
communication modules and equipment. By observing the following safety
principles, you can ensure your personal safety and help to protect the
product and the working environment from potential damage.
We are not liable for damages related to the customer’s failure to comply with
these regulations.
| Safety on the road comes first! When you are driving, do not use hand-held
mobile terminal devices unless they have a hands-free function. Please stop
the car before making a call!
---|---
| Please turn off your mobile devices before boarding the airplane. The
wireless function of mobile devices is prohibited on board to prevent
interference with the aircraft’s communication system. Ignoring this reminder
may lead to flight safety or even violate the law.
| When in a hospital or health care setting, note if there are restrictions on
the use of mobile devices.RF interference can cause medical equipment to
malfunction, so it may be necessary to turn off the mobile device.
| The mobile device does not guarantee a valid connection in all
circumstances, for example if the mobile device is out of credit or the SIM is
invalid. When you are in an emergency situation, please remember to use the
emergency call and make sure that your device is switched on and in an area
with sufficient signal strength.
| Your mobile device receives and transmits RF signals when it is switched on,
which can cause RF interference when near a TV, radio computer or other
electronic device.
| Keep the mobile terminal unit away from flammable gases. Turn off the mobile
device when you are near gas stations, oil depots, chemical plants, or
explosive workplaces. It is a safety hazard to operate electronic devices in
any place where there is a potential explosion hazard.
Applicable modules Options
serial number| Module Model| Supported Frequency Bands| sizes| Module
Introduction
---|---|---|---|---
1| L-BTMSB16-G0NP4| 2.4 GHz ISM Band| 9.4x14x2.4mm|
Introduction
SB16 series standard Bluetooth module is a high-performance IoT Bluetooth transceiver developed based on FR801X chip platform. The module adopts postage-stamp package and supports external antenna and on-board PCB antenna. At the same time, the module also supports 105℃ working temperature, which can adapt to high temperature scenarios. The product also features low power consumption, small size, and strong anti-interference capability.
Product Overview
2.1 Key Features
connector | Stamp Interface |
---|---|
wireless standard | BLE5.0 |
Module Packaging | 9.4x14x2.4mm |
operating voltage | 1.8V~4.3V, 3.3V typical |
operating frequency | 2402~2480MHZ(2.4 GHz ISM Band) |
operating temperature | -40 ~ +105°C |
Storage temperature | -40 ~ +105°C |
2.2 Product Advantages
- Protocol stack version: supports Bluetooth 5.0
- Chip core: ARM® Cortex®-M3 32-bit processor, 48 MHz
- Storage Resources: 512KB Flash + 48 KB RAM
- Physical layer rate: 1 Mbps
- Receiving sensitivity: -94dBm in 1Mbps
- Output power: MAX +10dBm
- Operating voltage: 1.8 – 4.3V, 3.3V typical
- Interface resources: 10GPIOs, 2UARTs
- Working temperature: -40 ~ 105°C
2.3 application scenario
- 2.4GHz low power Bluetooth system;
- PCs, tablets, cell phones, handhelds, and other low-power peripherals (HIDs, remote controls, etc.);
- Sports, healthcare and other consumer electronics;
- Wireless sensor networks for smart meters, data acquisition, etc;
- Photovoltaic, charging pile, industrial instrumentation and other industries;
- Smart home, LAN, interactive devices, beacon lights;
2.4 functional block diagram
2.5 Pinouts
2.6 Pin Description Table
pin | Pin Definitions | I/O Type | Functional Description |
---|---|---|---|
1 | PA4 | IO | SCL0/I2SCLK/PWM4/SSPCLK/URXD0/URXD1/CLKOUT/PDMCLK/PWM5 |
2 | PA5 | IO | SDA0/I2SFRM/PWM5/SSPCSN/UTXD0/UTXD1/ANTCTL1/PDMDAT/PWM4 |
3 | PA6 | IO | SCL1/I2SDOUT/PWM0/SSPDOUT/URXD0/URXD1/CLKOUT/PDMCLK/PWM1 |
4 | PC7 | IO | SDA1/I2SDIN/PWM5/SSPDIN/UTXD0/UTXD1/SWDIO/PDMDAT/PWM4 |
5 | GND | G | Ground |
6 | PC6 | IO | SCL1/I2SDOUT/PWM4/SSPDOUT/URXD0/URXD1/SWTCK/PDMCLK/PWM5 |
7 | PD7 | IO | SDA1/I2SDIN/PWM1/SSPDIN/UTXD0/UTXD1/ANTCTL1/PDMDAT/PWM0/ADC3 |
8 | PD6 | IO | SCL1/I2SDOUT/PWM0/SSPDOUT/URXD0/URXD1/CLKOUT/PDMCLK/PWM1/ADC2 |
9 | VBAT | P | Positive Supply Input |
10 | GND | G | Ground |
11 | RES | I | Global Reset (low active) |
12 | PD4 | IO | SCL0/I2SCLK/PWM4/SSPCLK/URXD0/URXD1/ANTCTL0/PDMCLK/PWM5/ADC0 |
13 | PD5 | IO | SDA0/I2SFRM/PWM5/SSPCSN/UTXD0/UTXD1/ANTCTL0/PDMDAT/PWM4/ADC1 |
14 | PA1 | IO | SDA0/I2SFRM/PWM1/SSPCSN/UTXD0/UTXD1/ANTCTL0/PDMDAT/PWM0 |
15 | PA0 | IO | SCL0/I2SCLK/PWM0/SSPCLK/URXD0/URXD1/CLKOUT/PDMCLK/PWM1 |
16 | PA7 | IO | SDA1/I2SDIN/PWM1/SSPDIN/UTXD0/UTXD1/ANTCTL0/PDMDAT/PWM0 |
17 | | R | RESERVED | |
18 | | R | RESERVED | |
19 | DB1 | R | Debug Only,Not Recommend |
19 | DB1 | R | Debug Only,Not Recommend |
--- | --- | --- | --- |
NOTE:
- “P”:POWER “I”:INPUT “O”:OUTPUT “G”:GND “R”:Reserved “:GND “R”:Reserved
- DB1 is internally connected to PA3 and DB2 is connected to PA2 ,they are for debugging only and are not recommended.
- PIN17 and PIN18 aren’t used for L-BTMSB16-G0NP4 ,must be kept unconnected.They are reserved for other types.
Application interface
3.1 UART Communication
The SB16 module provides one main UART0 communication interface.
3.1.1 Main serial port
The main serial port UART0 is defaulted to PA5 (TXD0) and PA4 (RXD0) for
command configuration and data transmission, the default baud rate is
115200bps, and the serial port connection schematic is as follows:
Specification
Table 4-1 Product Limit Parameters
Main parameters | performances | note |
---|---|---|
Min value | Max values | |
Supply Voltage (V) | 1.8 | 4.3 |
IO Voltage (V) | -0.3 | VDDIO+0.3 |
Storage temperature (℃) | -40 | 105 |
Working temperature (℃) | -40 | 105 |
VESD | 4000V | VBAT&ANT PIN ESD performance |
Table 4-2 Module Operating Parameters @25°C
Main parameters | performances | note |
---|---|---|
minimum value | typical value | maximu m values |
Operating voltage(V) | 1.8 | 3.3 |
Operating frequency band (MHz) | 2402 | / |
Emission current (mA) | / | 14.7 |
Receiving current (mA) | / | 19 |
Sleep current (μA) | / | 3.3 |
operating mode | 1Mbps | / |
communications protocol | Bluetooth 5.0 | / |
Number of channels | 40 | / |
Modulation Type | GFSK | / |
Transmit power (dbm) | -20 | / |
Receiving sensitivity (dbm) | / | -94 |
Application Notes
5.1 Baseboard Layout Considerations
The antenna needs to be surrounded by as large a headroom area as possible.
The headroom refers to the open area within the projection area of the
vertical plane of the antenna (the upper and lower ranges should be
considered). Within the projection area of the antenna, whether patch or side
insertion method, do not pave the ground (especially forboard mounted
antennas), there can be no metal devices, to maintain the antenna’s headroom,
in order to improve the antenna radiation efficiency. The RF part of the
module should avoid being wrapped by the metal cavity as much as possible, and
the distance between the RF part and the interference source should be more
than 10mm (the bigger the better if the conditions allow). Common sources of
interference include: batteries (including electrical connector), capacitors,
inductors, pushbuttons, oscillators, power cables, screws or nuts containing
metal, CPUs, LCDs, transformers, speakers, cameras, wiring of the product’s
internal communication interface, power supply circuits, motors, and so on.
Baseboard Layout Requirements.
Module PCB antenna should be in the whole bottom PCB edge, PCB antenna to keep
10mm spacing around the antenna, antenna around the layers can not cloth
copper, wire, layout components; if there are a variety of antennas, antennas
and antennas should be as far away as possible between the distance, to avoid
the same frequency interference and cross-modulation interference. The
following figure around the antenna, including the upper and lower vertical
range can not have metal devices, it is recommended to stick on the base
plate, this part of the region hollow processing. The following figure in the
gray area of the laying copper size is recommended in 4 * 4cm.Description of test points at the Module Bottom level:
RF performance of the test pads have a windowed area (that is, exposed
copper), the base plate mapped to the location can not be placed over the hole
or exposed copper, and should be covered with white oil to prevent short-
circuit. It is recommended that the bottom of the board alignment or exposed
copper to avoid the red box area in the following figure. 5.2 caveat
-
power supply
It is recommended to use a DC regulated power supply to power the module, the power supply ripple is as small as possible, usually requires a ripple of less than 30mV, the ripple is too large will lead to poor sensitivity and other connection anomalies. At the same time, the Bluetooth transmitting signal will be coupled into the interference signal, resulting in RF indicators beyond the Bluetooth specification, which will cause serious failure to connect and communicate. Try to use LDO to provide power to the module, and at the same time, LDO should be far away from DC-DC power supply and inductance to prevent DC-DC radiation from polluting the power supply of LDO. The module needs to be grounded reliably, and please pay attention to the correct connection of the positive and negative poles of the power supply, such as reverse connection may lead to permanent damage to the module.
A 10uF and 0.1uF decoupling capacitor is recommended for the SB16 module power pin (VBAT). The capacitor should be as close as possible to the VDD power supply pin. The power supply voltage range is 1.8~4.3V, and when using 3.3V power supply, we need to ensure that the power supply voltage is not lower than 1.8V. The VDD pin needs to meet the power supply capacity of 150mA peak current, and the power supply ripple is recommended to be less than 30mV, so as to avoid excessive ripple caused by the degradation of RF performance. The recommended circuits for power supply are as follows Note: D1 TVS static protection is used, it is recommended to place a TVS tube for static protection. -
ESD Electrostatic discharge protection
Users need to pay attention to the electrostatic requirements of the product during design, see Table 4-1, and add electrostatic protection measures to the design of the end product.
Mechanical dimensions
Production and Packaging Information
7.1 Production Welding
7.1.1 Production Guidelines
It is recommended that the stamp port encapsulated module be mounted using SMT
machine and the mounting should be completed within 24 hours after unpacking,
otherwise it should be re-vacuum-packed to avoid moisture leading to poor
mounting.
If the package contains a humidity indication card, it is recommended to judge
whether the module needs to be baked according to the humidity card
indication, and the conditions during baking are as follows:
Baking temperature: 125℃±5℃;
The alarm temperature is set to 130°C;
After cooling <36℃ under natural conditions, it is ready for SMT placement;
If the unpacking time is more than 3 months, you need to pay special attention
to whether the product is affected by moisture, because the PCB immersed gold
process, more than 3 months may lead to oxidation of the pads, the patch may
lead to false soldering, leakage of soldering and other problems.
In order to ensure that the reflow soldering pass rate, the first patch is
recommended to take 10% of the products for visual inspection, AOI testing to
ensure that the furnace temperature control, device adsorption method,
placement of the rationality of the way;
Operators at each station must wear electrostatic gloves during the entire
production process.
7.1.2 Module location requirements at the base plate
It is recommended that the base plate module location of the green oil
thickness of less than 0.02mm, to avoid excessive thickness, padding module
can not effectively contact with the solder paste affects the welding quality.
Also need to consider the interface board module location within 2mm around
the layout of other devices, in order to protect the maintenance of the
module.
7.1.3 Stencil opening design
The thickness of the stencil on the base plate is selected in principle
according to the type of packaging of the device on the board to be selected,
need to focus on the following requirements:
Module pad locations can be locally thickened to 0.15~0.20mm to avoid void
soldering.
7.1.4 Production Precautions
- During the production process, each operator must wear electrostatic gloves;
- Baking should not exceed the specified baking time;
- It is strictly prohibited to add explosive, flammable and corrosive substances during baking;
- During baking, modules should be placed in high temperature trays to maintain air circulation between modules;
- The door of the baking box needs to be closed during baking to ensure that the baking box is closed and to prevent the temperature from leaking out;
- Try not to open the door when the oven is running, if you have to open it, try to shorten the time you can open the door;
- After baking, wait until the module cools down naturally to below 36℃ before taking it out with electrostatic gloves to avoid burns;
- When operating, do not allow the bottom surface of the module to get wet or dirty;
7.1.5 Reflow soldering work instructions
Note: This work instruction is suitable for lead-free work only and is
for reference only.
7.2 Packaging
specification
7.2.1 Packaging
model number| Packagi ng| Full Carton(P CS)| Minimum
Packing Quantity (PCS)| Number of reels per case
---|---|---|---|---
L-BTMSB16-G0BP4| reel| 6500| 1300| 5
7.2.2 Belt size and product orientation
Federal Communication Commission (FCC) Radiation Exposure Statement
When using the product, maintain a distance of 20cm from the body to ensure
compliance with RF exposure requirements.
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications or changes to this
equipment. Such modifications or changes could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
ORIGINAL EQUIPMENT MANUFACTURER (OEM) NOTES
The OEM must certify the final end product to comply with unintentional
radiators (FCC Sections 15.107 and 15.109) before declaring compliance of the
final product to Part 15 of the FCC rules and regulations. Integration into
devices that are directly or indirectly connected to AC lines must add with
Class II Permissive Change.
The OEM must comply with the FCC labeling requirements. If the module’s label
is not visible when installed, then an additional permanent label must be
applied on the outside of the finished product which states: “Contains
transmitter module FCC ID: 2AOFDL-BTMSB16. Additionally, the following
statement should be included on the label and in the final product’s user
manual: “This device complies with Part 15 of the FCC Rules.
Operation is subject to the following
two conditions: (1) This device may not cause harmful interferences, and (2)
this device must accept any interference received, including interference that
may cause undesired operation.” The module is allowed to be installed in
mobile and portable applications A module or modules can only be used without
additional authorizations if they have been tested and granted under the same
intended end‐use operational conditions, including simultaneous transmission
operations. When they have not been tested and granted in this manner,
additional testing and/or FCC application filing may be required. The most
straightforward approach to address additional testing conditions is to have
the grantee responsible for the certification of at least one of the modules
submit a permissive hange application. When having a module grantee file a
permissive change is not practical or feasible, the following guidance
provides some additional options for host manufacturers. Integrations using
modules where additional testing and/or FCCapplication filing(s) may be
required are: (A) a module used in devices requiring additional RF exposure
compliance information (e.g., MPE evaluation or SAR testing); (B) limited
and/or split modules not meeting all of the module requirements; and (C)
simultaneous transmissions for independent collocated transmitters not
previously granted together.
This Module is full modular approval, it is limited to OEM installation ONLY.
Integration into devices that are directly or indirectly connected to AC lines
must add with Class II Permissive Change. (OEM) Integrator has to assure
compliance of the entire end product include the integrated Module. Additional
measurements (15B) and/or equipment authorizations(e.g. Verification) may need
to be addressed depending on co-location or simultaneous transmission issues
if applicable.(OEM) Integrator is reminded to assure that these installation
instructions will not be made available to the end user.
Company Address: Lierda Internet of Things Technology Park, No. 1326 Wenyi
West Road, Hangzhou
Tel:0571-88800000
Date: 23/08/14