lierda LSD4BTB-PBS1000001 S1 Beacon Explosion User Manual
- June 5, 2024
- lierda
Table of Contents
LSD4BTB-PBS1000001
User Manual
Product name: S1 beacon explosion proof version 2
Product model:LSD4BTB-PBS1000001
Version:Rev01
Document revision history
Number| Modify log| Modifier| Reviewer| Version|
Date
---|---|---|---|---|---
1| Origin| why| sxt| Rev01| 2020-4-22
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
Chapter 1 Summary
A chemical plant is a high-risk industrial field. In recent years, safety
accidents have caused great losses to employees and enterprises. Therefore,
personnel positioning management has become an effective means to reduce
potential safety hazards and realize digital and intelligent management in the
plant area. Bluetooth RSSI positioning is one of the existing indoor
positioning technologies. The factory staff can find out their own position
and report to the gateway by wearing positioning cards and scanning the RSSI
strength of the beacon. Lerida S1 positioning beacon is used as the
transmitter of positioning signal in a chemical plant. The advantage of this
technology is that the software and hardware design of the transmitter is
simple, and the power consumption is very low
1.1 Working principle
The S1 positioning beacon is installed on the indoor ceiling of the factory on
a grid basis. Each positioning beacon has its own unique ID number. The
personnel positioning
card is worn on the workers, and the Bluetooth module and Lora module are
integrated into the card. When the locator is in a certain position in the
room, the Bluetooth module in the card will search the RSSI signal strength
value of the beacon nearby, and then upload the data to the lorawan gateway
through the Lora module. The background determines the specific position of
personnel according to the RSSI value and beacon ID number.
1.2 Working conditions
- Temperature:-20℃~60℃;
- Average relative humidity: Less than 95%(25℃);
- Atmospheric pressure:80kPa~106kPa;
- CE working frequency: 2400MHZ~2483.5MHZ
- Transmit power: -20dBm~4dBm (adjustable by user APP)
Chapter 2 Instructions
2.1 Construction and installation instructions
As shown in the figure below, prepare several S1 type beacons according to the
indoor space size of the factory, and install them at an interval of 5m
according to the serial number. Note that the serial number in the drawing
should correspond to the ID number (minor) of the beacon. In addition to the
products, there are two M6 25mm expansion pipes, two M4 25mm cross
countersunk head screws, and two decorative caps in the packing box, which are
convenient for users to install and fix. 2.2 APP instructions
This product is equipped with two parallel ER14505 energy batteries. The
battery capacity can be used continuously for more than 5 years. As shown in
the figure below, users can download the bright beacon app to configure the
relevant parameters of the S1 beacon. The configurable parameters include
device name, transmission power and broadcast interval. At the same time,
users can directly view the remaining battery power through the app.
2.3 Accessories information
There are several accessories for users to fix our product to the ceiling. One
is a pressure-sensitive adhesive, customer can use this to attach a Beacon to
the concrete surfaces. Another accessory is an expansion screw, customer can
use an electric drill to fix our beacon to the solid wall. Both of the
accessories are shown in the pictures below.
Chapter 3 Matters needing attention
3.1 Precautions for product use
- Please do not hit, shake or throw the product violently to avoid failure;
- Please do not put the product near the microwave oven or high-voltage equipment, otherwise, the circuit may be damaged;
- It is forbidden to be close to fire source and water source when using;
- It is strictly forbidden to disassemble or modify the product, otherwise, it will cause damage, leakage, and circuit failure.
3.2 Battery related precautions
- It is strictly forbidden to short circuit the positive and negative electrodes of the battery, charge it, over-discharge it, and heat it to more than 100 ℃. Otherwise, it may cause explosion, combustion, and leakage of internal acidic substances;
- It is not allowed to use the battery outside the temperature range;
- When the battery is used to the end voltage, it should be taken out of the instrument in time and buried in the ground.
3.3 EU Declaration of Conformity
Hereby we,
Name of manufacturer: | Zhejiang Lierda IoThink Technology Co., Ltd |
---|---|
Address: | Room 301, Building No.1, Lerida IoT park, No.1326 Wenyi Xi Road, |
Hangzhou, Zhejiang Prov., China
Zipcode & City:| 311100 Hangzhou
Country:| China
Telephone number:| +86 18067988348
declare that this DoC is issued under our sole responsibility and that this product:
Product description: | S1 beacon explosion-proof version 2 |
---|---|
Type designation(s): | LSD4BTB-PBS1000001 , LSD4BTB-PBS2000001 , |
LSD4BT-PB95S10002,LSD4BT-PB95S10001
Trademark:| N/A
Batch / Serial number:|
The object of the declaration (further identification of the radio equipment
allowing traceability; it may include a color image for the identification of
the radio equipment):
……[Model:LSD4BTB-PBS1000001,LSD4BTB-PBS2000001,LSD4BT-PB95S10002, LSD4BT-
PB95S10001 The device is S1 beacon explosion-proof version 2, it supports
5.0 Bluetooth LE. For more details, pls refer to the user manual.] ……
is in conformity with the relevant Union harmonization legislation:
Radio Equipment directive: 2014 / 53 / EU a
nd other Union harmonization legislation where applicable:
with reference to the following standards applied:
EN 62368-1:2014+A11:2017
EN 301 489-1 V2.2.3(2019-11); EN 301 489-17 V3.2.4(2020-09)
EN 300 328 V2.2.2(2019-07)
EN 62479: 2010
Description of accessories and components, including software, which allows
the radio equipment to operate as intended and covered by the DoC:
Accessory:
.…………………………………………………………………………………………………………
Signed for and on behalf of:
_2020.11.26__
Place and date of issue
_Herry KimTest Manager
Name, Function, signature
3.4 FCC regulatory conformance
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
RF Exposure
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Notice to users
You are welcome to use the products of lierda Technology Group Co., Ltd. please read this notice before using our products. If you have already started using it, you have read and accepted this notice. Lerida Technology Group Co., Ltd. reserves the right of final interpretation and modification of all the information provided, subject to change without prior notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>