pylo 300-LTE Weight Scale Plus User Manual

June 15, 2024
PYLO

pylo 300-LTE Weight Scale Plus

Safety Information

Symbol Meaning

The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows:

CAUTION

  • The Pylo Weight Scale Plus offers you a way to manage your health. Please be aware that this device is designed for children(10-17 years old) and adults’ self-measuring. Any information provided by this device is in no way meant to treat, cure or prevent any disease or illness from happening.

  • The Pylo Weight Scale Plus is equipped with a data transmission function. It may emit electromagnetic energy so as to perform its intended function. Nearby portable and mobile RF communications equipment can affect the performance of the device.

  • Portable and mobile RF communications equipment can affect the measuring accuracy of the Pylo Weight Scale Plus.

  • Kindly note that the use of accessories, transducers or cables other than those specified, with the exception of transducers and cables sold by the manufacturer as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the device.

  • Be aware that misuse of electrical equipments can cause electric shock, burns, fire, and other hazards. Please do not use the device in flammable gas environment.
    Warning that the Pylo Weight Scale Plus should not be used adjacent to or stacked with other equipment.

  • The manufacturer will make available on request circuit diagrams, component parts lists, etc. WARNING: No modifications of this equipment is allowed.
    During measuring, the patient will contact with the upper surface of the scale. The ABS plastic surface of the scale is the type BF Applied part.

  • The device doesn’t need to be calibrated in a year’s lifetime. Do not touch the output of batteries when using the scale.

  • The patient is an intended operator. The patient can perform all the operations in the manual, such as measurement, data transmitting, and changing batteries

INDICATIONS FOR USE

The Pylo Weight Scale Plus measures body weight and can send weight data over the mobile 2G or 4G LTE network.

Your Scale and Its Environment

To ensure your safety as well as the service life of your scale, please avoid using the scale under the following circumstances:

  • Slippery floors such as tile floor
  • Jumping onto the platform immediately after a bath or with wet feet
  • Near a cell phone or microwave oven
  • Avoid storage in the following locations:
  • Where there is water
  • Where the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air
  • Where there is a risk of shock or drop
  • Where you store chemicals or full of corrosive gases
  • Where in reach of the infants or children

Efficient Use of Your Scale

To ensure the accuracy of measurement, please follow the below instructions when you start measurement.

  • Place the scale on a flat, hard surface. Soft surfaces such as carpet will affect the performance of the scale.
  • Start measurement at least two hours after Getting up or dining.
  • Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dining.
  • Always start measurement in the same time slot and on the same scale located on the same flat, hard surface.
  • This device is not intended for use in an oxygen rich environment.
  • Any information provided by this scale is in no way meant to treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician.
  • It is intended for use in the home only.

Overview

Device Components

List

  1. Weight Scale Plus 300-LTE
  2. Four AA-size Batteries (1.5V per each)
  3. User Manual

LCD Display

Initial Start-Up

General Instructions

Simply lay the scale on a level surface, step onto it, and then remain still. It will automatically turn on, take a weight reading, and then send the reading over the mobile network.\

Inserting Batteries and Initial Network Pairing

  • Slide open the battery door on the back of the scale.

  • Insert the batteries (4 x 1.5V AA) into the battery compartment, making sure to insert each battery following the configuration indicated inside the compartment.

  • Once the batteries are inserted, the scale will perform an initial secure pairing with the mobile network. This process normally takes around fifteen seconds but may take up to two minutes.

  • When initial pairing succeeds, the symbol “[ ]” will be shown on the display and the scale is ready to start taking measurements

  • If pairing fails, “E1” will be shown on the LCD. In this case, the scale is not able to connect to the mobile network. Please try again in a different location (near a window, if able) before calling customer service.
    You can determine the signal strength from the symbol in the upper left of the display:

CAUTION

  • When the symbol “ ” and “ Lo” appear, the device will power off. Then you shall replace it with a new set of batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new one.
  • Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries and scrapped devices.
  • Do not mix alkaline, standard (carbon-zinc), or rechargeable (Ni-Cd, Ni-MH, etc) batteries.
  • If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries before storing them.
  • Use the scale three times a day, and the lifetime of a battery is one year.

Select Measurement Unit

With batteries correctly installed, you will see the black “UNIT” button on the battery door. Press it to select the measurement unit. The default measurement unit is “lb”. You may press “UNIT” button to choose between pounds, kilograms, and stones.

Start Measuring

Daily Measurement

  • It is suggested that you weigh yourself each day at
  • approximately the same time. Simply step onto the
  • scale and it will automatically turn on and start taking a measurement.
    • When data is successfully transmitted, “oH” will be displayed. If the data transfer fails, “E1” will be displayed. In this case, the measurement is saved and transmission is reattempted with the next measurement taken.

Error Prompt

Troubleshooting

When Measuring

Problem Root Cause Solution



No display on LCD when the device powers on.

| ****


Batteries not yet installed.

| ****

Install the batteries. (Please refer to Insert the

Battery and Pair-up )



Worn batteries.

| Replace all four batteries at the same time. Please purchase the authorized batteries for replacement.



The device powers off automatically.

| ****


Low battery.

|

About the Accuracy of This Product

This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer. Please refer to the above table for the descriptions on accuracy.  This product is specially designed for Pylo Weight Scale Plus as well as weight measurement. It should NOT be used by anyone during the process of transaction for verification of goods’ weight.

Specifications

Product Name Pylo Weight Scale Plus
Dimension Scale: Approx. 360x360x37.2mm
Net Weight Approximately 3.04kg ( Excluding the dry cells)
Display Digital LCD
Measurement Unit Pound / Kilogram / Stone
Measurement Range 11lb to 551.2lb / 5kg to 250kg / 0st:11lb to 39st:

5lb
Division| 0.1kg / 0.2lb

Accuracy

| 50kg±0.2kg;100kg±0.3kg;150kg±0.4kg; 200kg±0.5kg;250kg±0.8kg

Working Environment

| Temperature: 5℃ to 40℃   Relative Humidity: ≤90% RH Atmospheric pressure: 86kPa to 106kPa

Storage Environment

| Temperature: -20℃ to 60℃  Relative Humidity: ≤90% RH Atmospheric pressure: 50kPa to 106kPa
Power Source| 6V (Four AA-size Batteries)
Auto- ON| SENSE ON technology
Auto-OFF| About 10 seconds while showing 0.0;
Accessories| 1.  Four AA-size Batteries

2. User Manual

Mode of Operation| Continuous Operation

Protection Against Ingress of Water

| IP22(The first number 2: Protected against solid foreign objects of 12.5 mm Ф and greater. The second number 2: Protection against vertically falling water drops when enclosure tilted up to 15°on either side of the vertical.)
Software Version| A5
Degree of protection| Type BF applied part

Maintenance

When carrying out usual maintenance, please ensure practice of the following Do’s and Don’ts:

  • DO use a soft dry cloth for routine cleaning of the device.
  • DO use a lightly moist cloth for cleaning the device when needed but do not use
  • soap or detergent. Use a soft dry cloth immediately afterwards to dry the device.
  • DON’T wash the device with water or immerse it in water.
  • DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunction.
  • DON’T disassemble this device. If you have any problems, please contact Pylo
  • Health. (Please refer to Warranty for contact information)

Warranty

  • Pylo warrants its products free of defects in materials and workmanship in normal use for a period of one year from the date of retail purchase.
  • This warranty does NOT cover damages caused by misuse or abuse, including but not limited to:
  • Failure caused by unauthorized repairs or modifications;
  • Damage caused by shock or drop during transportation;
  • Failure caused by improper operation inconsistent with the instructions stated in this user manual;
  • Malfunction or damage from failure to provide the recommended maintenance; Damage caused by improper use of power supply.
  • Should this device require maintenance (or replacement at our option) under warranty, please contact Pylo Health at the information below with your purchase receipt information and device defect information
  • to obtain a return authorization.

FCC Regulations

FCC User Guide Information
Radio Frequency Interface Requirements – FCC
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna;
  • Increase the separation between the equipment and receiver;
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected;
  • Consult the dealer or an experienced radio / TV technician for help.

Radio Transmitters (Part 15)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC RF Exposure Guidelines

Safety Information
Reducing RF Exposure – Use Properly Only operate the device in accordance with the instructions supplied. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment.

Appendix

Warning

The Pylo 300-LTE weight scale is suitable for home healthcare environments. Warning: Don’t use near HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.

  • Warning : Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
  • Warning: Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
  • Warning :Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.

EMC Guidance

Guidance and manufacturer’s declaration -electromagnetic emissions and Immunity

Table 1

Guidance and manufacturer’s declaration – electromagnetic emissions

Emissions test| Compliance
RF emissions

CISPR 11

| Group 1
RF emissions

CISPR 11

| Class B
Harmonic emissions

IEC 61000-3-2

| Not applicable
Voltage fluctuations/ flicker emissions

IEC 61000-3-3

| Not applicable

Table 2

Guidance and manufacturer’s declaration – electromagnetic Immunity

Immunity Test| IEC 60601-1-2

Test level

| Compliance level
Electrostatic discharge (ESD)

IEC 61000-4-2

| ±8 kV contact

±2 kV, ±4 kV, ±8 kV, ±15 kV air

| ±8 kV contact

±2 kV, ±4 kV, ±8 kV, ±15 kV air

Electrical fast transient/burst

IEC 61000-4-4

| Not applicable| Not applicable
Surge

IEC 61000-4-5

| Not applicable| Not applicable
Voltage dips, short interruptions and voltage variations on power supply input lines

IEC 61000-4-11

| Not applicable| Not applicable
Power frequency magnetic

field

| 30 A/m

50Hz/60Hz

| 30 A/m

50Hz/60Hz

IEC 61000-4-8|  |
Conducted RF

IEC61000-4-6

| Not applicable| Not applicable
Radiated RF IEC61000-4-3| 10 V/m

80 MHz – 2,7 GHz

80 % AM at 1 kHz

| 10 V/m

80 MHz – 2,7 GHz

80 % AM at 1 kHz

NOTE UT is the a.c. means voltage prior to application of the test level.

Table 3

Guidance and manufacturer’s declaration – electromagnetic Immunity

Radiated RF IEC61000-4-3

(Test specifications for ENCLOSURE PORT IMMUNITY to

RF wireless communications equipment)

| Test Frequency (MHz)| Band

(MHz)

| Service| Modulation| Modulation

(W)

| Distance

(m)

| IMMUNITY TEST LEVEL

(V/m)

385| 380 –

390

| TETRA 400| Pulse modulation 18 Hz| 1,8| 0.3| 27
450| 430 –

470

| GMRS 460,

FRS 460

| FM

± 5 kHz deviation 1 kHz sine

| 2| 0.3| 28
710| 704 –

787

| LTE Band 13,

17

| Pulse modulation 217 Hz| 0,2| 0.3| 9
745
780
810| 800 –

960

| GSM 800/900, TETRA 800,

iDEN 820,

CDMA 850,

LTE Band 5

| Pulse modulation 18 Hz| 2| 0.3| 28
870
930
1720| 1 700 –

1 990

| GSM 1800; CDMA 1900;

GSM 1900; DECT;

LTE Band 1, 3,

4, 25;

UMTS

| Pulse modulation 217 Hz| 2| 0.3| 28
1845
1970
2450| 2 400 –

2 570

| Bluetooth, WLAN, 802.11

b/g/n, RFID 2450,

LTE Band 7

| Pulse modulation 217 Hz| 2| 0.3| 28

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals