zigbee HY366 Radiator Actuator User Manual
- June 21, 2024
- zigbee
Table of Contents
Zigbee Radiator Actuator
User Manual
HY366 Radiator Actuator
Many thanks for your selection of our products and services, and also for your trust and support
Download “Smart life” or “Smart RM” App from Google play and App store| 1.
After the ZigBee gateway is configured, enter the gateway to add sub-devices,
and wait for the actuator to be powered on and the system self-check is
completed.
2. long press and to active flashing access network connected mode.
Please refer to the gateway manual for Zigbee gateway configuration.
---|---
Product Specifications
Power: 2 AA alkaline batteries
Working temperature: 0-50℃
Display accuracy::0.5℃
Running program: Set per 1 week as a cycle
Probe sensor::NTC(10k)1%
Size(mm):5389.5mm
Maximum route:4.5mm
Range of temperature display: 1~70°C
Default range of temperature adjustment: 5~35°C
Maximum current: 90mA
Working environment temperature: -10~60°C
Thread size: M30*1.5
Displays & Buttons
No.| Icon|
---|---|---
A| Auto Mode; Manual mode Energy saving mode Low battery; Children lock;
Boost mode; Open Window function Comfort mode Auto mode period Holiday mode
B| Room temperature Time setting Zigbee connection status
Set temperature/Advanced options Valve status
keys| Represent
---|---
| 1. Short press to switch manual mode and auto mode
2. Long press to enter advanced setting
| 1. Short press to switch comfort mode and energy saving mode
2. Long press for 3 seconds to view valve open status
| 1. Short press to start the BOOST function: turn on the BOOST fast heating
mode, short press any key during operation to exit this function and return to
the previous working mode
2. When setting other functions, short press is the confirmation
3. Long press for 3 seconds to lock/unlock keys
Rotation| 1. Clockwise, the value increases
2. Counterclockwise, the value decreases
Installation and initial commissioning
After power on, the screen will show all for 3 seconds.|
---|---
Time setting: when flashing,then press enter hour setting ,turn the rotation
to adjust the value,press again enter minute setting, turn the rotation to
adjust the value,press again to set week,turn the rotation to adjust the
value,press to confirm setting and remember time.
Note: after the actuator completes its self-check,under normal working
status,if need to modify time, long press 3s access to advanced setting. And
short press to choose , short press enter time setting. the same as above
method.|
When display “Ad”, press Start system self-check, when display “1”, this is
the first step of system self-check. When Display “2”, this is the second step
for self-check, after finish self-check, If there is no fault prompt, it will
enter the normal working state. If there is a fault prompt, please handle the
fault first, otherwise it will not enter the normal working state.|
E1| Motor fault
E2| Sensor fault
| Flashing show low battery
Special Function description
Holiday mode| Press 3s access to advanced setting , short press to
choose holiday mode , then short press enter temperature setting, again short
press days setting, turn the rotation to adjust value, then short enter
holiday mode.Under holiday mode, short press to exit holiday mode.
---|---
Open Window Function| 1. The actuator turns off the window opening
function by default, if you need to use it, you can turn it on in the advanced
option 2 setting [reset disable when changing the battery]
Comfort mode| Press and hold for 3 seconds to enter the advanced
setting, short press to switch to the comfort mode , short press to enter the
comfort mode parameter setting, turn the rotation to adjust value
Energy saving mode| Press and hold for 3 seconds to enter the advanced
setting, short press to switch to the energy saving mode , short press to
enter the energy saving mode parameter setting, turn the rotation to adjust
value
Auto mode setting
Long press about 3s access to advanced setting, short press switch to auto mode setting , short press access to auto mode setting, short press to choose which item you want. First set the auto mode to 5 means :5=5+2 days, 6 = 6+1 days, 7 = 7 days, after press to access to hour or minute setting, short press again access to temperature setting, turn the rotation to adjust value. short press choose: hour,minute, time period, and turn the rotation to adjust value, finished setting, about 10 seconds will automatic save and exist.
Period | Default period | Default temperature |
---|---|---|
1 | 6:00 | 20℃ |
2 | 8:00 | 15℃ |
3 | 11:30 | 15℃ |
4 | 12:30 | 15℃ |
5 | 17:30 | 20℃ |
6 | 22:00 | 15℃ |
Advanced options
Press and hold for 3-5 seconds to enter the advanced setting, short press to select the advanced option parameter setting icon , short press to enter the advanced option parameter setting, turn the rotation to adjust value, after each parameter is set, short press to enter the next option setting, all After the setting is completed, the key is not operated for 10 seconds, the parameters are saved and the setting is exited.
No | Item | Setting parameters | default |
---|---|---|---|
1 | Measuring temperature correction | -9-+9℃(Displayed as the corrected room | |
temperature value) | -1°C | ||
Open window function | 1: display means disable open window | ||
function,rotating the knob clockwise display | |||
2 | parameter: temperature and running time | 5°C means this function |
enable(temperature setting range: 5-25°C)
2: Running time:5-60min(after enable function, press change setting)|
3| Automatic lock if no operation more than 10 minutes| 0: Disable
1: Enable| 0
4| Setting temperature minimum limit| 1-15°C| 5°C
5| Setting temperature maximum limit| 16-70°C| 35°C
6| BOOST mode running time| 100s-900s , Steps of 100 seconds| 300
7| Start/stop working temperature difference setting| 0.5-1.5| 1
8| Control type of valve| 0: PID 1:FLOAT 2:ON/OFF|
9| Backlight display time| Setting range: 5-10 seconds. When 00 is disable
backlight function, the knob clockwise will display 05, indicating that the
backlight function has been enable, and the backlight lighting time is 5
seconds;| 00
A| Reset| Display 88, Turn the knob clockwise or counterclockwise to change
the parameter to 00, press to reset, The screen will be fully displayed for 2
seconds.|
B| Valve Seal Type| 0:Soft Seal 1:Hard Seal|
C| Descaling function| 0: Disable descaling function 1: Enable descaling
function|
1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>