zigbee HY366 Radiator Actuator User Manual

June 21, 2024
zigbee

zigbee Logo Zigbee Radiator Actuator
User Manual

HY366 Radiator Actuator

Many thanks for your selection of our products and services, and also for your trust and support

Download “Smart life” or “Smart RM” App from Google  play  and  App store| 1. After the ZigBee gateway is configured, enter the gateway to add sub-devices, and wait for the  actuator to be powered on and the system self-check is completed.
2. long press and  to active flashing access network connected mode.
Please refer to the gateway manual for Zigbee gateway configuration.
---|---

Product Specifications

Power: 2 AA alkaline batteries
Working temperature: 0-50℃
Display accuracy::0.5℃
Running program: Set per 1 week as a cycle
Probe sensor::NTC(10k)1%
Size(mm):53
89.5mm
Maximum route:4.5mm
Range of temperature display: 1~70°C
Default range of temperature adjustment: 5~35°C
Maximum current: 90mA
Working environment temperature: -10~60°C
Thread size: M30*1.5

Displays & Buttons

No.| Icon|
---|---|---
A| Auto Mode;  Manual mode  Energy saving mode  Low battery; Children lock; Boost mode;  Open Window function  Comfort mode Auto mode period  Holiday mode
B|  Room temperature  Time setting Zigbee connection status
Set temperature/Advanced options Valve status
keys| Represent
---|---
| 1. Short press to switch manual mode and auto mode
2. Long press to enter advanced setting
| 1. Short press to switch comfort mode and energy saving mode
2. Long press for 3 seconds to view valve open status
| 1. Short press to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode
2. When setting other functions, short press is the confirmation
3. Long press for 3 seconds to lock/unlock keys
Rotation| 1. Clockwise, the value increases
2. Counterclockwise, the value decreases

Installation and initial commissioning

After power on, the screen will show all for 3 seconds.|
---|---
Time setting: when  flashing,then press  enter hour setting ,turn the rotation to adjust the value,press again enter minute setting, turn the rotation to adjust the value,press  again to set week,turn the rotation to adjust the value,press  to confirm  setting and remember time.
Note: after the actuator completes its self-check,under normal working status,if need to modify time, long press  3s access to advanced setting. And short press to choose , short press enter time setting. the same as above method.|
When display “Ad”, press  Start system self-check, when display “1”, this is the first step of system self-check. When Display “2”, this is the second step for self-check, after finish self-check, If there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state.|
E1| Motor fault
E2| Sensor fault
| Flashing show low battery

Special Function description

Holiday mode| Press  3s access to advanced setting , short press  to choose holiday mode , then short press  enter temperature setting, again short press  days setting, turn the rotation to adjust value, then short  enter holiday mode.Under holiday mode, short press  to exit holiday mode.
---|---
Open Window Function| 1. The actuator turns off the window opening function by default, if you need to use it, you can turn it on in the advanced option 2 setting [reset disable when changing the battery]
Comfort mode| Press and hold for 3 seconds to enter the advanced setting, short press to switch to the comfort mode , short press  to enter the comfort mode parameter setting, turn the rotation to adjust value
Energy saving mode| Press and hold for 3 seconds to enter the advanced setting, short press  to switch to the energy saving mode , short press  to enter the energy saving mode parameter setting, turn the rotation to adjust value

Auto mode setting

Long press about 3s access to advanced setting, short press switch to auto mode setting , short press access to auto mode setting, short press to choose which item you want. First set the auto mode to 5 means :5=5+2 days, 6 = 6+1 days, 7 = 7 days, after press to access to hour or minute setting, short press again access to temperature setting, turn the rotation to adjust value. short press choose: hour,minute, time period, and turn the rotation to adjust value, finished setting, about 10 seconds will automatic save and exist.

Period Default period Default temperature
1 6:00 20℃
2 8:00 15℃
3 11:30 15℃
4 12:30 15℃
5 17:30 20℃
6 22:00 15℃

Advanced options

Press and hold for 3-5 seconds to enter the advanced setting, short press to select the advanced option parameter setting icon , short press to enter the advanced option parameter setting, turn the rotation to adjust value, after each parameter is set, short press to enter the next option setting, all After the setting is completed, the key is not operated for 10 seconds, the parameters are saved and the setting is exited.

No Item Setting parameters default
1 Measuring temperature correction -9-+9℃(Displayed as the corrected room
temperature value) -1°C
Open window function 1: display  means disable open window
function,rotating the knob clockwise display
2 parameter: temperature and running time 5°C means this function

enable(temperature setting range: 5-25°C)
2: Running time:5-60min(after enable function, press  change setting)|
3| Automatic lock if no operation more than 10 minutes| 0: Disable
1: Enable| 0
4| Setting temperature minimum limit| 1-15°C| 5°C
5| Setting temperature maximum limit| 16-70°C| 35°C
6| BOOST mode running time| 100s-900s , Steps of 100 seconds| 300
7| Start/stop working temperature difference setting| 0.5-1.5| 1
8| Control type of valve| 0: PID   1:FLOAT  2:ON/OFF|
9| Backlight display time| Setting range: 5-10 seconds. When 00 is disable backlight function, the knob clockwise will display 05, indicating that the backlight function has been enable, and the backlight lighting time is 5 seconds;| 00
A| Reset| Display 88, Turn the knob clockwise or counterclockwise to change the parameter to 00, press  to reset, The screen will be fully displayed for 2 seconds.|
B| Valve Seal Type| 0:Soft Seal 1:Hard Seal|
C| Descaling function| 0: Disable descaling function 1: Enable descaling function|

1

zigbee Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

zigbee User Manuals

Related Manuals