R37 EPH Controls Zone Programmer Installation Guide

June 15, 2024
EPH CONTROLS

R37 EPH Controls Zone Programmer

“`html

Specifications

  • Switch Output: Auto
  • Power Supply: 200-240V~ 50/60Hz
  • Ambient Temperature: HOT WATER HEATING
  • Dimensions: 161mm x 31mm x 100mm
  • Contact Rating: British System Standard 2
  • Program Memory Temperature Sensor: Class A
  • Backlight: Off
  • IP Rating: Not specified
  • Battery: Not specified
  • Backplate: EPH Controls Ltd.
  • Pollution degree: 3
  • Software Class: EPF Controls Ltd.

Product Usage Instructions

Mounting & Installation

Caution! Installation and connection should only be carried out
by a qualified person. Only qualified electricians or authorised
service staff are permitted to open the programmer. If the
programmer is used in a way not specified by the manufacturer, its
safety may be impaired. Prior to setting the programmer, it is
necessary to complete all required settings described in this
section. Before commencing installation, the programmer must be
first disconnected from the mains.

This programmer can be surface mounted or mounted to a recessed
conduit box.

  1. Remove the programmer from its packaging.

  2. Choose a mounting location for the programmer:

    • Mount the programmer 1.5 metres above the floor level.
    • Prevent direct exposure to sunlight or other heating/cooling
      sources.
  3. Use a philips screwdriver to loosen the screws of the backplate
    on the bottom of the programmer. The programmer is lifted upwards
    from the bottom and removed from the backplate.

FAQ

Q: Can I install the programmer myself?

A: Installation and connection should only be carried out by a
qualified person. Only qualified electricians or authorised service
staff are permitted to open the programmer.

Q: What should I do before setting up the programmer?

A: Before setting up the programmer, ensure that it is
disconnected from the mains and complete all required settings as
described in the installation instructions.

Q: How should I choose a mounting location for the

programmer?

A: Mount the programmer 1.5 metres above the floor level and
avoid direct exposure to sunlight or other heating/cooling
sources.

“`

R37 V2
3 Zone Programmer Installation and Operating Guide

Table of contents

Installation Instructions

Factory Default Settings

3

Specifications

3

LCD Display

4

Button Description

5

Wiring Diagram

6

Mounting & Installation

7

Operating Instructions

Quick Introduction to your R37V2 programmer

10

Mode Selection

11

Programming Modes

12

Factory Program Settings

12

Adjust the Program Setting in 5/2 Day Mode

13

Reviewing the Program Settings

14

Boost Function

14

Advance Function

15

Operating Instructions Continued

Menu

16

P01 Setting the Date, Time and the Programming Mode

16

P02 Holiday Mode

17

P03 Frost Protection

18

P04 Zone Title

19

P05 PIN

20

Copy Function

22

Backlight Mode Selection

23

Locking the Keypad

24

Resetting the Programmer

24

Master Reset

25

Service Interval

25

3 Zone Programmer Installation Instructions

Factory Default Settings

Program: Backlight: Keypad Lock: Frost Protection:

5/2D On Off Off

Operating Mode: Pin Lock: Service Interval: Zone Title:

Specifications
Switch Output: Power Supply: Ambient Temperature: Dimensions: Contact Rating: Program Memory Temperature Sensor: Backlight: IP Rating: Battery:

SPDT Volt Free 230VAC 0 … 50°C 161 x 100 x 31 mm 3(1)A 230VAC 5 Years NTC 100K White IP20 3VDC Lithium LIR2032 & CR2032

Backplate: Pollution degree:
Software Class:

EPH Controls Ltd.

Auto Off Off HOT WATER HEATING 1 HEATING 2
British System Standard 2 (Resistance to voltage surge 2000V; as per EN60730) Class A
3

LCD Display
[1] Displays current time. [2] Displays current day of the week. [3] Displays when frost protection is activated. [4] Displays when keypad is locked. [5] Displays current date. [6] Displays zone title. [7] Displays current mode.

[3] [2] [4] [5] [1] [6] [7]

4

R37V2

Button Description

Boost Button Boost
Menu Button
MENU

Zone Select Button
Select

Program Advance Plus Minus Button Button Button Button

PROG

ADV

OK Button
OK

Master Reset

EPH Controls Ltd.

5

Wiring Diagram

ZONE

ZONE

ZONE

LN

1

2

3

ON OFF ON OFF ON OFF

200-240V~ 50/60Hz

Terminal Connections

Earth

1

Live

2

Neutral

3

Zone 1 ON – N/O Normally open connection

4

Zone 1 OFF – N/C Normally closed connection

5

Zone 2 ON – N/O Normally open connection

6

Zone 2 OFF – N/C Normally closed connection

7

Zone 3 ON – N/O Normally open connection

8

Zone 3 OFF – N/C Normally closed connection

6

R37V2

Mounting & Installation

161

31

100

EPH Controls Ltd.

7

Mounting & Installation continued
Caution!
Installation and connection should only be carried out by a qualified person. Only qualified electricians or authorised service staff are permitted to open the programmer. If the programmer is used in a way not specified by the manufacturer, its safety may be impaired. Prior to setting the programmer, it is necessary to complete all required settings described in this section. Before commencing installation, the programmer must be first disconnected from the mains.
This programmer can be surface mounted or mounted to a recessed conduit box.

  1. Remove the programmer from its packaging. 2) Choose a mounting location for the programmer:
    – Mount the programmer 1.5 metres above the floor level. – Prevent direct exposure to sunlight or other heating / cooling sources. 3) Use a philips screwdriver to loosen the screws of the backplate on the bottom of the programmer. The programmer is lifted upwards from the bottom and removed from the backplate.
    (See Diagram 3 on Page 7)
  2. Screw the backplate onto a recessed conduit box or directly to the surface.
  3. Wire the backplate as per the wiring diagram on page 6. 6) Sit the programmer onto the backplate making sure the programmer pins and the backplate
    contacts are making a sound connection, push the programmer flush to the surface and tighten the screws of the backplate from the bottom. (See Diagram 6 on Page 7)

8

R37V2

3 Zone Programmer Operating Instructions

Quick introduction to your R37V2 programmer:
The R37V2 programmer will be used to control three separate zones in your central heating system.
Each zone can be independently operated and programmed to suit your needs. Each zone has up to three daily heating programs called P1, P2 and P3. See Page 13 for instructions on how to adjust the program settings.
On the LCD screen of your programmer you will see three separate sections, one to represent each zone.
Within these sections you can see what mode the zone is currently in.
When in the AUTO mode, it will show when the zone is next programmed to be switched ON or OFF.
For `Mode Selection’ please see page 11 for further explanation.
When the zone is ON, you will see the red LED for that zone light up. This indicates that power is being sent from the programmer on this zone.

10

R37V2

Mode Selection

AUTO

There are four modes available for selection.

AUTO The zone operates up to three `ON/OFF’ periods per day (P1, P2, P3).

ALL DAY The zone operates one ON/OFF’ period per day. This operates from the firstON’ time to the third ‘OFF’ time.

ON

The zone is permanently ON.

OFF

The zone is permanently OFF.

Press Select to change between AUTO, ALL DAY, ON & OFF.

The current mode will be shown on the screen under the specific zone.

The Select are found under the front cover. Each zone has its own Select .

EPH Controls Ltd.

11

Programming Modes
This programmer has the following programming modes. 5/2 Day mode Programming Monday to Friday as one block and
Saturday and Sunday as a 2nd block. 7 Day mode Programming all 7 days individually. 24 Hour mode Programming all 7 days as one block.

Factory Program Settings 5/2d

Mon-Fri Sat-Sun
All 7 days
Everyday

P1 ON 06:30 07:30
P1 ON 06:30
P1 ON 06:30

P1 OFF 08:30 10:00
P1 OFF 08:30
P1 OFF 08:30

5/2 Day P2 ON 12:00 12:00
7 Day P2 ON 12:00
24 Hour P2 ON 12:00

12

R37V2

P2 OFF 12:00 12:00
P2 OFF 12:00
P2 OFF 12:00

P3 ON 16:30 17:00
P3 ON 16:30
P3 ON 16:30

P3 OFF 22:30 23:00
P3 OFF 22:30
P3 OFF 22:30

Adjust the Program Setting in 5/2 Day Mode

Press PROG .

Programming for Monday to Friday for Zone 1 is now selected. To change programming for Zone 2 or Zone 3, press the appropriate Select . Press and to adjust the P1 ON time. Press and to adjust the P1 OFF time. Repeat this process to adjust P2 and P3 times.

Press OK . Press OK .

Programming for Saturday to Sunday is now selected.

Press and to adjust the P1 ON time.

Press OK .

Press and to adjust the P1 OFF time.

Press OK .

Repeat this process to adjust P2 and P3 times.

Press MENU to return to normal operation.

While in programming mode, pressing Select will jump to the next day (block of days) without changing the program.

Note:
1. To change from 5/2d to 7D or 24H programming, refer to page 16, Menu P01.
2. If you don’t wish to use one or more of the daily programs then simply set the start time and end time to be identical. For example, if P2 is set to start at 12:00 and end at 12:00 the programmer will simply ignore this program and proceed to the next switching time.

EPH Controls Ltd.

13

Reviewing the Program Settings
Press PROG . Press OK to scroll through the periods for the individual day (block of days). Press Select to jump to the next day (block of days). Press MENU to return to normal operation. You must press the specific Select to review the schedule for that zone.

Boost Function
Each zone can be boosted for 30 minutes, 1, 2 or 3 hours while the zone is in the AUTO, ALL DAY & OFF mode. Press Boost 1, 2, 3 or 4 times, to apply the desired BOOST period to the Zone. When a Boost is pressed there is a 5 second delay before activation where `BOOST’ will flash on the screen, this gives the user the time to select the desired BOOST period. To cancel a BOOST, press the respective Boost again. When a BOOST period has ended or has been cancelled, the Zone will return to the mode that was previously active prior to the BOOST.
Note: A BOOST cannot be applied while in the ON or Holiday Mode.

14

R37V2

Advance Function
When a zone is in the AUTO or ALLDAY mode, the Advance function allows the user to bring the zone or zones forward to the next switching time. If the zone is currently timed to be OFF and ADV is pressed, the zone will be switched ON until the end of the next switching time. If the zone is currently timed to be ON and ADV is pressed, the zone will be switched OFF until the start of the next switching time. Press ADV . Zone1, Zone 2, Zone 3 and Zone 4 will begin to flash. Press the appropriate Select . The zone will display ADVANCE ON’ orADVANCE OFF’ until the end of the next switching time. Zone 1 will stop flashing and enter Advance mode. Zone 2 and Zone 3 will remain flashing. Repeat this process with Zone 2 and Zone 3 if required. Press OK To cancel an ADVANCE, press the appropriate Select . When an ADVANCE period has ended or has been cancelled, the zone will return to the mode that was previously active prior to the ADVANCE.

EPH Controls Ltd.

15

Menu
This menu allows the user to adjust additional functions. To access the menu, press MENU .

P01 Setting the Date, Time and the Programming Mode DST ON

Press MENU , `P01 tInE’ will appear on the screen. Press OK , the year will begin to flash.

Press and to adjust the year.

Press OK .

Press and to adjust the month.

Press OK .

Press and to adjust the day.

Press OK .

Press and to adjust the hour.

Press OK .

Press and to adjust the minute.

Press OK .

Press and to adjust from 5/2d to 7d or 24h mode.

Press OK .

Press and to turn DST (Day Light Saving time) On or Off. Press MENU and the programmer will return to normal operation.

Note: Please see page 12 for descriptions of Programming Modes.

16

R37V2

P02 Holiday Mode

This menu allows the user to switch off their heating system by defining a start and end date.

Press MENU , `P01′ will appear on the screen.

Press until `P02 HOL’ will appears on the screen.

Press OK , `HOLIDAY FROM’, the date and time will appear on the screen. The year will begin to flash.

Press and to adjust the year.

Press OK .

Press and to adjust the month.

Press OK .

Press and to adjust the day.

Press OK .

Press and to adjust the hour.

Press OK .

`HOLIDAY TO’ and the date and time will appear on the screen. The year will begin to flash.

Press and to adjust the year.

Press OK .

Press and to adjust the month.

Press OK .

Press and to adjust the day.

Press OK .

Press and to adjust the hour. The programmer will now be switched off during this selected period.

Press OK .

To cancel the HOLIDAY, press OK . The programmer will return to the normal operation when a holiday has finished or been cancelled.

EPH Controls Ltd.

17

Menu continued

P03 Frost Protection OFF

This menu allows the user to activate the frost protection between a range of 5°C and 20°C.

Frost protection is default set to OFF. Press MENU , P01′ will appear on the screen. Press untilP03 FrOST’ appears on the screen. Press OK , `OFF’ will appear on the screen.

Press to select ON’.5°C’ will flash on the screen.

Press OK .

Press and to select your desired frost protection temperature.

Press OK .

Press MENU and the programmer will return to normal operation.

The Frost symbol will display on the screen if the user activates it in the menu.

If the ambient room temperature drops below the desired frost protection temperature, all zones of the programmer will activate and the frost symbol will flash until the frost protection temperature has been achieved.

18

R37V2

P04 Zone Title
This menu allows the user to select different titles for each zone. The options are:

DEFAULT OPTIONS HOT WATER HEATING 1 HEATING 2

RENAME OPTIONS ZONE 1 ZONE 2 ZONE 3

Press MENU , P01′ will appear on the screen. Press untilP04′ appears on the screen. Press OK , HOT WATER’ will flash on the screen. Press to change from HOT WATER’ to ZONE 1′. Press OK .Heating 1′ will flash on the screen. Press to change from HEATING 1′ toZONE 2′. Press OK . Heating 2′ will flash on the screen. Press to change fromHEATING 2′ to `ZONE 3′. Press MENU and the programmer will return to normal operation.

EPH Controls Ltd.

19

Menu continued P05 PIN
This menu allows the user to put a PIN lock on the programmer. The PIN lock will reduce the functionality of the programmer. Set up the PIN
Press MENU , P01′ will appear on the screen. Press untilP05 PIn’ appears on the screen. Press OK , OFF’ will appear on the screen. Press to change from OFF to ON. Press OK .0000′ will flash on the screen. Press and to set the value from 0 to 9 for the first digit. Press OK to move to the next PIN digit. When the last digit of the PIN is set, press OK . Verify is displayed with `0000′. Press and to set the value from 0 to 9 for the first digit. Press OK to move to the next PIN digit. When the last digit of the PIN is set, press OK . The PIN is now verified, and the PIN lock is activated.
If the verification PIN is entered incorrectly the user is brought back to the menu. When the PIN lock is active the Lock symbol will flash every second on the screen. When the programmer is PIN locked, pressing the menu will take the user to the PIN unlock screen. Note: When the PIN lock is enabled, BOOST periods are reduced to 30 minute and 1 hour periods. When the PIN lock is enabled, Mode Selections are reduced to Auto and OFF.

20

R37V2

To Unlock the PIN

Press MENU , UNLOCK’ will appear on the screen.0000′ will flash on the screen.

Press and to set the value from 0 to 9 for the first digit.

Press OK to move to the next PIN digit.

When the last digit of the PIN is set.

Press OK .

The PIN is now unlocked.

If a PIN has been unlocked on the programmer, it will automatically reactivate if there is no button pressed for 2 minutes.

To Deactivate the PIN

When the PIN is unlocked (see above instructions)

Press MENU , `P01′ will appear on the screen.

Press until `P05 PIn’ appears on the screen.

Press OK , `ON’ will appear on the screen.

Press or to select `OFF’.

Press OK .

`0000′ will flash on the screen. Enter the PIN. The PIN is now disabled.

Press OK .

Press MENU to return to normal operation or it will automatically exit after 20 seconds.

EPH Controls Ltd.

21

Copy Function
Copy function can only be used when the 7d mode is selected. (See page 16 to select 7d mode) Press PROG to program the ON and OFF periods for the day for the week you want to copy. Do not press OK on the P3 OFF time, leave this period flashing. Press ADV , COPY’ will appear on the screen, with the next day of the week flashing. To add the desired schedule to this day press . To skip this day press . Press OK when the schedule has been applied to the desired days. Ensure the zone is in theAuto’ mode for this schedule to operate accordingly. Repeat this process for Zone 2 or Zone 3 if required.
Note: You cannot copy schedules from one zone to another, E.g. Copying Zone 1 schedule to Zone 2 is not possible.

22

R37V2

Backlight Mode Selection ON

There are 3 backlight settings available for selection:

AUTO Backlight stays on for 10 seconds when any button is pressed.

ON

Backlight is permanently On.

OFF

Backlight is permanently Off.

To adjust the backlight press and hold OK for 10 seconds. `Auto’ appears on the screen. Press or to change the mode between Auto, On and Off. Press OK to confirm selection and to return to normal operation.

EPH Controls Ltd.

23

Locking the Keypad
To lock the programmer, press and hold and together for 10 seconds. will appear on the screen. The buttons are now disabled.
To unlock the programmer, press and hold and for 10 seconds. will disappear from the screen. The buttons are now enabled.

Resetting the Programmer
To reset the programmer to factory settings: Press MENU . P01′ will appear on the screen. Press untilP06 rESEt’ appears on the screen. Press OK to select. nO’ will begin to flash. Press , to change fromnO’ to `YES’. Press OK to confirm.
The programmer will restart and revert to its factory defined settings. The time and date will not be reset.

24

R37V2

Master Reset
To master reset the programmer to factory settings, locate the master reset button on the right-hand side underneath the programmer. (see page 5) Press the Master Reset button and release it. The screen will go blank and reboot. The programmer will restart and revert to its factory defined settings.
Service Interval OFF
The service interval gives the installer the ability to put an annual countdown timer on the programmer. When the Service Interval is activated `SErv’ will appear on the screen which will alert the user that their annual boiler service is due.
For details on how to enable or disable the Service Interval, please contact customer service.

EPH Controls Ltd.

25

EPH Controls IE
technical@ephcontrols.com www.ephcontrols.com/contact-us +353 21 471 8440 Cork, T12 W665
EPH Controls UK
technical@ephcontrols.co.uk www.ephcontrols.co.uk/contact-us +44 1933 322 072 Harrow, HA1 1BD