OnTime AS1109 Non Pedestal Antenna Solutions User Manual

June 13, 2024
ONTIME

ONTIMENON-PEDESTALANTENNASOLUTIONS
USERMANUAL
AS1109/AS1110/OS0263/OT7251

Hardwares

1.1 OS0263 AP Station and Remote Control(OT7251)

OnTime AS1109 Non Pedestal Antenna Solutions 0S0263 AP Station

No. Components Descriptions
1 Power Port Input power is DC 12V
2 Mode Switch Switch to Regional Mode or Access Control Mode
3 Identification Code Set same ID code to realize the Extension Mode
4 Power Indicator The indicator is on when power is connected
5 Alarm Indicator The indicator is on when alarm is triggered
6 Remote signal receiver Can use Remote Control the adjust Volume and

Sensitivity

Remote Control(OT7251)

  • VOL-/VOL+ :Volume adjust button
  • Range-/Range+: Detection Range adjustt( Performance)
  • Alarm Light: Alarm Light Color change (reserved function)
  • Back Light:Background Light Color change (reserved function)

1.2 AS1109 Padlock Tag

OnTime AS1109 Non Pedestal Antenna Solutions - Padlock
Tag A AS1109 Remote Control

No. Components Directions
1 Activating button Insert the steel wire to activate the tag, pull out the

steel wire by magnet detacher to deactivate
2| Steel wire| Cut the steel wire will trigger off the alarm, pull out the steel wire by magnet detacher to stop the alarm

1.3 AS1110 Sticky Tag

OnTime AS1109 Non Pedestal Antenna Solutions - Sticky
Tag A\ AS1110 Picture of Sticky Tag

No. Components Directions
1 Deactivating&Alarm button tag will be in working mode when the button is

pressed down, and will alarm if the button is released.
2| Reset button| dis-alarm by pressing the reset button if the tag alarm is triggered.

1.4 Detacher
Only applies to AS1109 Padlock TagOnTime AS1109 Non Pedestal Antenna
Solutions - Detacher

Instructions

The Power supply is only required on the 0OS0263 AP Station, the connection method is as following:

AS1109 Padlock Tag

There are 3 working modes of Non-Antenna Solutions: Regional Mode, Access Control Mode, Extension Mode.
For Regional Mode, the tag should be bound to the AP Station, for Access Control Mode, binding is not required.
The operation is as following:
3.1 Activate the Tag
Insert the Steel wire into the tag lock hole, the tag is locked and activated when a “Tick” sounds. OnTime AS1109 Non Pedestal Antenna Solutions - Padlock
Tag Picture of locked&Deactivated Padlock Tag
3.2 Tag Binding
Put the activated Tag close to the AP Station(<<20cm), the tag is bound to the AP Station automatically when a ‘Tick’ sounds.OnTime AS1109 Non Pedestal
Antenna Solutions - Padlock TagTag Unbinding: the tag will automatically unbind with the AP station when unlocking the tag by detacher. 3.3 Working Mode
AS1109 have 3 working modes: Regional Mode, Access Control Mode, ExtensionMode.
» Regional Mode

  1. There’s black switch on the back of 0S0263 AP Station, switch it to the Right, will be the Regional Mode, then the AP Station will alarm if the tag is moved out of the detection area.
  2. Hang the tag on the product to be protected, put the AP station on the Table.
  3. When the tag is brought close to the AP station( within 20cm), the tag and AP station will beep twice at the same time, means the tag and AP station is bound automatically.
  4. Take the tag away from the detection area(beyond 4meters), both the tag and AP station will alarm.
  5. Take the product with tag back to the detection area(within 0-4meters), alarm eliminates.
    Note: both the tag and AP Station alarm will eliminates automatically if the tag leaves detection area more than 15s.

» Access Control Mode

  1. There’s black switch on the back of 0S0263 AP Station, switch it to the left, will be the Access Control Mode, then the AP Station will alarm if the tag is moved in the detection area.
  2. Hang the tag on the product to be protected, and hang the AP station on top of the entrance;
  3. Take the tag to go through the entrance detection area(within 0-4m), both the Tag and AP station will alarm;
  4. Take the tag away from the detection area(beyond 4m), alarm eliminates.

Extension Mode
With Extension Mode, the detection area can be extended with 2 or more AP Stations.
For example, there are two AP stations: A and B.

  1. The Tag can be bound to any of the AP Stations, A or B.
  2. Set the ID codes of AP station A and B to the same position.
  3. If the Tag leaves the detection area of AP Station A, AP station A alarms. When the tag goes to the detection area of AP Station B, AP station A stops alarm.

3.4 Change BatteryOnTime AS1109 Non Pedestal Antenna Solutions - Change
Battery By inserting the steel cable plug in a reverse direction, the battery bracket can be took out by hand easily to change the battery.
Note: do not place the battery upside down.

 Sticky Tag

There are 3 working modes of Non-Antenna Solutions: Regional Mode, Access
Control Mode, Extension Mode.
For Regional Mode, the tag should be bound to the AP Station, for Access Control Mode, binding is not required.
The operation is as following:
4.1 Activate the Tag
The tag deactivated automatically when the button ( marked as 1 in the picture below) is pressed. 4.2 Tag Binding
Put the deactivated Tag close to the AP Station(<<20cm), the tag is bound to the AP Station automatically after a ‘Tick’ sounds. Tag Unbinding: tear off the tag from the protected product, the tag will automatically unbind when the button is released.
4.3 Working Mode(same as Padlock Tag above)
There are 3 working modes: Regional Mode, Access Control Mode, Extension Mode.
» Regional Mode

  1. There’s black switch on the back of 0S0263 AP Station, switch it to the Right, will be the Regional Mode, then the AP Station will alarm if the tag is moved out of the detection area.
  2. Stick the tag on the the product to be protected, and put the AP station on the table;
  3. When the tag is brought close to the AP station( within 20cm), the tag and AP station will beep twice at the same time, means the tag and AP station is bound automatically.
  4.  Tear off the tag from product( button 1 released) will trigger the alarm, press reset button 2 manually to eliminate the alarm.OnTime AS1109 Non Pedestal Antenna Solutions - Sticky Tag
  5. Take the tag away from the detection area(beyond 4meters), both the tag and AP station will alarm.
  6. Take the product with tag back to the detection area(within 0-4meters), alarm eliminates.
    Note: both the tag and AP Station alarm will eliminates automatically if the tag leaves detection area more than 15s.

» Access Control Mode

  1. There’s black switch on the back of 0S0263 AP Station, switch it to the left, ill be the Access Control Mode, then the AP Station will alarm if the tag is moved in the detection area.
  2. Stick the tag on the the product to be protected, and hang the AP station on top of entrance table.
  3. Tear off the tag from product( button 1 released) will trigger the alarm, press reset button 2 manually to eliminate the alarm.
  4. Take the tag to go through the entrance detection area(within 0-4m), both the Tag and AP station will alarm;
  5. Take the tag away from the detection area(beyond 4m), alarm eliminates.

Extension Mode
With Extension Mode, the detection area can be extended with 2 or more AP Stations.
For example, there are two AP stations: A and B.

  1. The Tag can be bound to any of the AP Stations, A or B.
  2. Set the ID codes of AP station A and B to the same position.
  3. If the Tag leaves the detection area of AP Station A, AP station A alarms.
    When the tag goes to the detection area of AP Station B, AP station A stops alarm.

4.4 Change Battery

OnTime AS1109 Non Pedestal Antenna Solutions - Change
Battery Use screw driver to release the battery cover and change the battery.
Note: do not place the batter upside down.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals