PROVISION I5PT-390AX4/X10 1080p 4in1 Bullet Mini Ptz Camera User Manual

June 3, 2024
PROVISION

390AX4/X10 1080p 4in1 Bullet Mini Ptz Camera
User Manual

Summary

This document describes the correct installation and operation methods of I5PT-390AX4/10 Models.
1.1 Important Safety Notes:
Please read this manual carefully before installing and operating the camera.

  • Please refer to the technical specs to confirm you are using a suitable power supply. Do not use power supply with higher/lower rating than specified.
  • Do not attempt to disassemble the camera; in order to prevent electric shock, do not remove any screws or covers.
  • There are no user-serviceable parts inside. Please contact the nearest service center if there is any technical failure.
  • Avoid incorrect operation, shock vibration or heavy weight pressing which can damage the camera.
  • Do not use corrosive detergent to clean the camera. If necessary, please use a soft dry cloth to wipe dirt. For tough contamination, use neutral detergent. Any cleanser for high grade furniture is applicable.
  • Avoid aiming the camera directly towards extremely bright objects such as the sun, as it may permanently damage the image sensor.
  • Please follow the installation instructions.
  • Do not operate the camera in environments that exceeds the specified temperature, humidity or power.
  • Keep away from any heat sources such as radiators, heat registers, stoves, etc.
  • Do not expose the product to the direct airflow of an air conditioner.

Box Contents

ITEM QUANTITY
I5PT-390AX4/10 Camera 1
Camera Bracket 1
User Manual 1
Installation Screws 4

Structure
3.1 Camera Cable
Please find cable description below. You can also refer to Figure 2-1. There might be some differences among  different serial products.

S/N ITEM QUANTITY
1 Video Connector 4in1 1080P Video Output
2 Power Connector 12V DC Power Input (2A Recommended)
3 RS-485 Connector Orange: RS-485A, Yellow: R -485B

PROVISION I5PT-390AX4X10 1080p 4in1 Bullet Mini Ptz Camera -
Fig

Device Installation

PROVISION I5PT-390AX4X10 1080p 4in1 Bullet Mini Ptz Camera -
Fig1

The camera is designed for a wall installation only! Please refer to the installation instructions below.
Important:

  1. The installation surface should be able to hold at least triple the weight of the  ssembled camera.
  2. The camera default output is PAL system, for NTSC, please call preset 68

Step 1: Install the camera’s bracket to the wall:
For cement wall:

  1. Mark the holes locations on the wall.
  2. Drill into the marked holes
  3. Use the supplied screw anchors
  4. Fix the bracket to the wall using the supplied screws.

For wood wall:

  1. No need to drill the wall or use screw anchors.
  2. Fix the bracket to the wall using the supplied screws.

Step 2: Install the camera:

  1. Pass the camera’s cable through the installed bracket.
  2. Secure the camera to the bracket using the supplied screws.
  3. Make all connections (Connect Power source last)

Step 3: Connect the camera to a controller:

  1.  Connect the camera to a controlling device such as RS-485 keyboard or DVR (By CoC/RS-485).
  2. If required, adjust corresponding address and baud rate. Make sure you can control the device.

Warnings:

  1. Do not adjust the camera’s orientation manually. This might damage the device.
  2. Do not hang anything form the camera’s bracket as it is not designed to hold overloads.

Camera Settings & Preset Commands:
If you are using CVI, use the 2 In this camera, the CoC commands divides to 2. If you are using AHD/TVI/CVBS, Please use the 1st table.
AHD/TVI/CVBS Command

Shortcut Key Function (Set Preset)
Set #84preset Proportional PIT OFF
Set #85preset,Call N Set video signal type
N=2 TVI
N=3 CVI
N=4 CVBS
Set #87preset,Call N N is address(N=1,2,3…… 254)
Set #88preset,Call N N is baud rate(1. 2400; 2.4800; 3.9600 )
Set # 89preset Delete all presets
Set #90 preset Set left limit Position
Set #9lpreset Set right limit Position
Set #92 preset Delete left/right limit
Set #93preset Dome restart
Set #94 preset Restore Factory Setting
Set #95preset Open main menu
Set #96 preset 0S Park time ON
--- ---
Set #97 preset 60S Park time ON
Set #98preset 120S Park time ON
Set #99 preset scan and tour scan speed is automatic
Set #100 preset scan and tour scan speed is high, 15°/ s e c
Set #101preset scan and tour scan speed is middle, 10°/ s e c
Set #102preset scan and tour scan speed is low, 5°/ s e c
Set #103 preset Record Pattern scan 1
Set #104 preset Record Pattern scan 2
Set #105 preset Record Pattern scan 3
Set #106 preset Record Pattern scan 4
Set #111 preset Set color-to-black function
Set #112 preset the preset-dwell: 0S
Set #113preset the preset-dwell: 5S
Set #114preset the preset-dwell: 10S
Shortcut key Function (Call preset)
Call #67 preset Change system to PAL
Call #68 preset Change system to NTSC
Call #69 preset Open Advanced Settings menu
Call #70 preset Preset Error Correction
Call #71 preset Proportional P/T ON
Call #72 preset Start Cruise scan and switch the cruise scan
Call #73 preset Start Pattern 1
Call #74 preset Start Pattern 2
Call #75 preset Start Pattern 3
Call #76 preset Start Pattern 4
Call #77 preset Call cruise 1 (default number 1~16 preset)
Call #78 preset Call cruise 2 (default number 17~32 preset)
Call #79 preset Call cruise 3 (default number 33~48 preset)
Call #80preset Call cruise 4 (default number 49~64 preset)
Call #81 preset Camera IR-CUT switch
Call #82 preset Call all valid presets cruise
Call #83 preset Call 250°scan
Call #95preset Open main menu (Same response as “Set”)

CVI Command

Shortcut Key Function (Set Preset)
**** Set #50preset,Call N Set output model
N=2 TVI
N=3 CVI
N=4 CVBS
Set #51preset Proportional P/T OFF
Set #52preset,Call N N is address(N=1,2,3……254)
Set #53preset,Call N N is baud rate(1. 2400; 2.4800; 3.9600 )
Set # 54preset Delete all presets
Set #55 preset Restore Factory Setting
Set #56 preset 0S Park time ON
Set #57 preset 60S Park time ON
Set #58preset 120S Park time ON
Set #59preset scan and tour scan speed is high, 15°/sec
Set #60preset scan and tour scan speed is middle, 10°/sec
Set #61preset scan and tour scan speed is low, 5°/sec
Set #62preset Set color-to-black function
Set #63preset the preset-dwell: 0S
Set #64preset the preset-dwell: 5S
Set #65preset the preset-dwell: 10S
Shortcut key Function (Call preset)
--- ---
Call #50 preset Camera IR-CUT switch
Call #51preset Call all valid presets cruise
Call #52preset Open main menu (Same response as “Set”)
Call #53 preset Open Advanced Settings menu
Call #54 preset Preset Error Correction
Call #55preset Proportional P/T ON
Call #56 preset Start Cruise scan and switch the cruise scan direction
Call #57 preset Start Pattern 1
Call #58preset Start Pattern 2
Call #59preset Start Pattern 3
Call #60 preset Start Pattern 4
Call #61 preset Call cruise 1 (default number 1~16 preset)
Call #62preset Call cruise 2 (default number 17~32 preset)
Call #63 preset Call cruise 3 (default number 33~48 preset)
Call #67 preset Change system to PAL
Call #68 preset Change system to NTSC

Note: Sequence default includes preset 1-preset 10 with parking time of 10sec.
Camera Specs:

Model I5-PTZ
I5PT-390AX10 I5PT-390AX4
CCD 1/3″ CMOS
Resolution HD Analog
Analog 700TVL
Optical Zoom x10 (5.1-51mm)
Digital Zoom No
Minimum Focus Distance 13M
Horizontal Angle of View H: 50.4°(Wide) to 5.4°(Tele) V: 29.7°(Wide) to
3°(Tele) 81.2°(Wide) to 22.6°(Tele) 1 51.5°(Wide) to 12.8°(Tele)
Sync System Internal
Min. Illumination 0.01Iux (0 Lux with IR On)
Day & Night Auto/Day/Night (ICR)
S/N Ratio >50dB
Focus Auto/Manual
[Auto Gain Auto/Manual
Wide-D No
White Balance ATW/Manual/Outdoor/Indoor
BLC On/Off
[-Shutter Speed 1/50-1/10000
Sense Up No
Noise Reduction 3D-DNR
Stabilizer No
Flip On/Off
Picture Freeze No
Iris Auto
Flikerness No

Pan/Tilt Specification

iPan tilt Range 250° Pan/ 65° Tilt
Pan tilt Speed Max Preset Speed: 12°/Sec

Manual: 0.5°-12°/Sec (Proprtional to Zoom)
I Preset| 255
Pattern| Up to 4
Auto Scan| Yes
Group| 4 Groups (Non-Configurable)
Schedule| No
Privacy Zone Masking| No
Park Function| Yes (Preset 1 Only)

Communication Specification

Data Type CoC* (Control over Coax), RS-485
Protocols CoC / Pelco-D
Baud Rates 2400
Camera ID 1 – 255
Alarm I/O No
On Screen Display OSD menu, Camera position

Machanical

IR Distance 50m IR LED Array
Fan / Heater No
Sunshield Yes
Humidity range <90%
Power Supply  12VDC/2A (Not supplied)
Operation temperature -20°C-+50°C
Dimensions 225175*94mm
Ingress Protection IP66
Weight  920gr

CoC must be supported on the controlling unit as well
CoC not supported in CVBS mode

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>