PROVISION-ISR PoES-16250GCL+2SFP Color LCD PoE Switch User Manual

June 3, 2024
PROVISION-ISR

PROVISION ISR -logo Color LCD PoE Switch

PoES-16250GCL+2SFP Color LCD PoE Switch

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-

User Manual

● PoES-16250GCL+2SFP     PoES-16250CL+2G+2SFP
● PoES-24370GCL+2SFP  PoES-24370CL+2G+2SFP

COLOR LCD POE SWITCH USER MANUAL

Notes

  • Before operating the switch, we strongly advise users to read this manual and keep it for later use.
  • Please use the supplied power cord.
  • Avoid incorrect operation, shock, vibration or heavy pressing which can cause damage to the switch.
  • Do not use corrosive detergent to clean the body of the switch. If necessary, please use a soft dry cloth to wipe dirt; for hard contamination, use neutral detergent. Any cleanser for  high‐grade furniture is applicable.
  • Do not operate the switch in extreme temperatures or extreme humidity conditions.
  • Keep away from heat sources such as radiators, heat registers, stove, etc.
  • The instructions in this manual could be outdated; if you need any clarifications you can contact an authorized PROVISION‐ISR technician. PROVISION‐ISR reserves the right to add changes to this manual and publish it online on our website (www.provision‐isr.com): ther may be inconsistencies with the latest version. This applies to any and all software upgrades and product improvements, interpretation and modification added. These changes will be published in the latest version without prior notification.
  • All pictures and examples used in the manual are for reference only.

Package Contents

Check the following contents of your package:

  • PoE Switch    x 1
  • User’s Manual    x 1
  • Power Cord    x 1
  • Accessories (Rack mount ears2, Rubber Feet4, Bracket screws*8)
    If any part is lost and damaged, please contact your local agent immediately.

Introduction

Thank  you  for  choosing  Provision‐ISR’s  PoE  Switch.  The  16/24GE(PoE)+2G SFP  LCD  Display PoE  switch have 16(24)‐10/100/1000Mbps PoE  RJ45 Port and 2‐Gigabit SFP  Slot. Its  PoE ports can automatically detect and supply  power with  those  IEEE  802.3af/at  compliant Powered Devices (PD). The electrical power is transmitted along with data in one single cable  allowing you to expand your network where there are no power lines or outlets, where you  wish to fix devices such as AP, IP Cameras or IP Phones, etc. The LCD can be used to display the PoE work status, accurate measurement total load  and for each port independently. This can help the installer and engineer to quickly discover  and solve network failures and improve work efficiency and quality.

Port Feature

Model PoE Ports PoE Ports Speed Uplink Ports Uplink Ports Speed
PoES‐16250GCL+2SFP 16 (1‐16) 10/100/1000Mbps 2 SFP (17‐18) 10/100/1000Mbps
PoES‐24370GCL+2SFP 24 (1‐24) 10/100/1000Mbps 2 SFP (25‐26) 10/100/1000Mbps
PoES‐16250CL+2G+2SFP 16 (1‐16) 10/100Mbps 2SFP + 2RJ‐45 (17‐20)

10/100/1000Mbps
PoES‐24370CL+2G+2SFP| 24 (1‐24)| 10/100Mbps| 2SFP + 2RJ‐45 (25‐28)| 10/100/1000Mbps

Hardware Description

2.1) Front Panel:
The Front Panel of the PoE Switch consists of Ethernet Ports, LCD Display + controls and LED  indicators.
Giga (10/100/1000Mbps Switches) Front panel illustration.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig1

10/100Mbps Switches Front panel illustration.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig2

LED indicators

LED Color Function
**** PWR **** Green Off :     Switch is off / No power supply.

Light : The switch is on.
**** LNK/ACT| **** Orange| Off :    No device is connected to the corresponding port.
Light : Indicates the link through that port is successfully established at 10/100Mbps.
Blink : Indicates that the Switch is actively sending or receiving data over that port.
**** Green| Off :    No device is connected to the corresponding port.
Light : Indicates the link through that port is successfully established at 1000Mbps.
Blink : Indicates that the Switch is actively sending or receiving data over that port.
**** PoE| ** Orange| Off :    No PoE powered device (PD) connected.
Light : There is a PoE PD connected to the port and power is supplied successfully.
Blink** : Indicates port abnormal power supply.

2.2) Rear Panel
The rear panel of the PoE Switch contains a full range AC inlet power socket (100 to 240V AC,  50/60HZ) and a grounding screw. In case the AC cord is not connected to ground, you must ground the unit using the grounding screw!

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig3

LCD Features:

This PoE switch line is equipped with color  LCD  display  and  PoE.  The  LCD can  display  the  status of  the switch as well as independent status for each of the PoE  ports such  as:  Output  power, Overload, Short circuit, Light load, Low voltage, Over voltage, High temperature Etc.

3.1) General Status Indicators:

  1. Port Number. Remaining ports will be displayed in the next page.
  2. Port power consumption
  3. Port download real‐time bandwidth.
  4. Port upload real‐time bandwidth.
  5. PB: the total “PoE budget” of the switch
  6. TP: “Total power” under current use
  7. PD: Numbers of “PD device”
  8. Norm:  Work  mode.  “Norm”  for  normal,  VLAN  and CCTV available

3.2) General Warnings:

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig5

Problem: Power supply failure
Result: Switch restart|    Problem: High AC voltage input
Result: Ports are off to prevent damage|  Problem: Low AC voltage input
Result: Ports are off to prevent damage

3.3) Port Status Warnings:

OLP (Overload  Protection): The port is overloaded and was shut down.
ULP (Underload Protection): The port is consuming  extremely low power which might indicate a fault and  therefore the port has shut down.
SCP  (Short‐Circuit  Protection):  The  port  appears  to  be short‐circuited and was shut down
OFF: Port not in use

3.4) Menu and Operations:
Click and hold the menu button for 5 second in order to access the main menu:

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig7

Scroll the menu using the “Up” and “Down” buttons, confirm using the “Enter” button and cancel/go  back using the “Back” button.
The main menu contains 12 options. The next chapter will go through it.

3.4.1. Switch Mode:
The Color LCD PoE switch series support 3 working modes:

  1. Normal: The switch operates as a normal IEEE 802.af/at PoE switch in standard operation mode.

  2. Fixed VLAN: This will enable a pre‐made VLAN settings that will prevent the downlink ports from any communications between themselves. The VLAN enhances security by preventing unauthorized connection to any available port to communicate with the IP cameras and other equipment connected to the switch. It will also optimize network traffic.

  3. CCTV Mode: CCTV mode will enable “Fixed VLAN” together with restricting the downlink port  bandwidth to 10Mbps duplex communication. The CCTV mode allows the installer to reach  distances of up to 250m over standard Cat.5e cable.

3.4.2. Port Bandwidth Limit:
This feature allows you to monitor and restrict the incoming  bandwidth coming from a single port. Once crossed, the switch will set a buzzer alarm to warn for bandwidth overuse. Once  enabled, this setting will take effect on all downlink ports. It  cannot be set for a specific port.  The default setting is “Disabled” meaning that there is no  bandwidth restriction. The other options are 400Mbps,  500Mbps and 600Mbps.

3.4.3. PD Type:
There are 3 types of PD. Enhance, Standard and Legacy.  Enhance: The default settings. It will detect at/af modes and  increase the current surge limit to the if at standard is used.  Standard: Full conformity with the IEEE 802.3 af/at standards.  Legacy: Should be used if the PD device does not comply with the IEEE 802.3af standard. The switch will try to detect  compliance with legacy standards and supply power to the PD if  detected. This operation mode should not be used unless advice  by the PD manufacturer, as it might supply power to devices not  designed to receive PoE and damage it.

3.4.4. Keep Alive:
Keep alive is designed to detect a malfunction of a PD device  that caused it to stop communication and make attempt to  restore its connection by hard rebooting it by taking and  restoring power. This feature is designed to increase the  system’s reliability and reduce maintenance to the system.  The Keep Alive can be set for each of the PoE ports individually.  The settings should be done as follows:  Port (01‐16/24): The required port number  Status (Disabled/Enabled): The Keep Alive Status

Startup (60~300s): The estimated startup time of the PD device. Once a PD is connected to the  specified port, a countdown will commence from the entered value. For example. If the “Startup”  setting was set to 180, once a PD device will be connected a countdown of 180 seconds will  commence. The switch will expect to detect incoming/outgoing traffic from the PD before the  countdown reaches 0.
Interval (60~300s): The interval is the allowed time without incoming/outgoing traffic from the PD.  Once no traffic is detected, the countdown will commence according to the configuration. If there is  still no traffic by the countdown reaches 0 the switch will execute a hard bootup procedure.   Power Off (5~60s): This value determines the duration of the power cut for the required switch. After  this countdown reaches 0, the switch will restore power to the port and let the PD device boot and  initialize.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig12

3.4.5. PSE Power Adjust:
The PSE (Power Source Equipment) is the main power supply unit for the switch. In order to increase  its life and reliability its rate is actually higher than the stated power bank, but it is reserved for  situations where PD power requirement suddenly peaks for a short moment.
In case the devices connected to the switch reaches the PB  limit, you can manually increase it and utilize more power to  the PoE ports on the expense of the reserve power.

This feature has 4 options:

  1. Normal (100%)
  2. Add 5% (105% PB)
  3. Add 10% (110% PB)
  4. Add 15% (115% PB)

Note: In order to make sure that the PSE is not overloaded for a long time, please make sure that the  TP is lower than the PB

3.4.6. PSE Port Priority:
The PoE switch has a power bank (PB) measured in Watts (W).  PD will require power from the power bank. This power will be  marked as Total Power (TP). Once the TP is higher than the PB,  the switch will automatically shut down ports in order not to  overload and damage itself.  PSE Port Priority allows the user to configure the priority of
the ports – actually setting order of which the ports will shut  down.

The priorities are as follows:
Critical: Devices set to “Critical” will shut down last
High: Device set to “High” will shut down once all the “Low” priority devices as shut down.
Low Priority (Default Settings): These devices will shut down first.

3.4.7. PSE Port Condition:
This setting will determine whether the switch is allowed to  distribute PoE to the specified channel. This setting is mainly  useful after the initial setting of the network and the PD  devices. After the system is up, all ports without PD devices  and all unused ports should be disabled from receiving PoE. It  will prevent overloading the system by unrequired PoE devices. “Enable” is the default setting.  This setting will only affect PoE and will not affect network  communication.

3.4.8. PoE Port Power:
This setting can limit the power supplied to a specific port as required. Each port can be configured  independently.

  1. Port: Port number for configuration.
  2. Power (6‐36W): The power limit for the port. Skips in 2W intervals.
    Note:  PoE Port Power is available for configuration only if the PD type is set to “Enhanced”/”Legacy”.
    If the PD type is set to “Standard” the PoE Port Power is automatically set to 32W and cannot be  modified.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig16

3.4.9. LCD State:
This setting will determine the duration of which the LCD  monitor will stay on. The options are as follows:

  1. Never (Always On): The LCD monitor will stay on.
  2. 10 min (Default Setting): The LCD will turn off after  10 minutes.
  3. 20 min: The LCD will turn off after 20 minutes.
  4. 30 min: The LCD will turn off after 30 minutes.

3.4.10. Fan Control:
This setting will determine the switch internal fan  working mode. The options are as follows:

  1. Always On: The fan will stay on regardless of the  PB status.
  2. 20% PB (Default Setting): The fan will turn on once  the PB reaches 20% consumption.
  3. 40% PB: The fan will turn on once the PB reaches  40% consumption.
  4. 60% PB: The fan will turn on once the PB reaches 60% consumption.

3.4.11. Default Settings:
Use this option if you wish to reset all switch settings and configuration back to factory default.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig19

3.4.12. About:
This will show you general information about the PoE Switch.

Switch Installation:

 This section describes how to install your Ethernet Switch in the best manner and make proper  connections. Please follow the following instructions in avoid of incorrect installation which might  cause device damage and potential security threat.  General Instructions:

  • Do not place the switch near water or any damp area. Prevent water or moisture from entering  the switch chassis.
  • Do not place the switch on an unstable case or desk. The switch might be damaged severely in  case of a fall.
  • Ensure proper ventilation of the equipment room and keep the all the ventilation openings of the  switch free of obstruction.
  • Make sure that the operating voltage and current matches the power input labeled on the switch.
  • Do not open the chassis while the switch is operating or when electrical hazards are present to  avoid electrical shock.
  • Before cleaning the switch, unplug the power plug of the switch first. Do not clean the switch  with wet cloth or liquid.

4.1) Desktop Installation:
For desktop installation, please attach the supplied cushioning rubber feet on the bottom of each  corner  of  the  Switch. This will prevent the switch from shifting or sliding and will reduce shock in  case  of  external  vibration. Allow  adequate  space  for  ventilation  between  the  device  and  the objects around it.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig21

4.2) Rack Mount Installation
The switch is rack‐mountable and can be installed on any EIA‐19  compatible rack.  Before  installation,  please  install  the  mounting  brackets  on the  switch side panels (one on each side),  secure them with the provided screws. Do not use different screws  since  longer  screws  might  damage the switch components and shorter screws might not bear the weight of the switch after  installation.
After the brackets has been installed, use the rack mount screws (not included), in order to securely  mount the switch on the rack.
Step 1:  Bracket installation

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig22

Step 2 : Mounting the switch on the rack.

PROVISION ISR PoES 16250GCL 2SFP Color LCD PoE Switch-
fig23

4.3) Turning on the switch
Please plug the power supply into the switch, the internal power system of the switch can Auto‐ regulate the working power according to the actual input power. When the switch is power on, the  power indicator will be light on the front panel of the switch shines.
Note: Please confirm the voltage is correct before power on, otherwise the switch will be  damaged. (There is a power supply socket on the back panel of the PoE Ethernet switch. The  power input is: 100V‐240Vac, 50/60Hz.)