Homedics UHE-CMTF45 Ultrasonic Humidifier with UV-C Instruction Manual

June 1, 2024
Homedics

Homedics UHE-CMTF45 Ultrasonic Humidifier with UV-C

Homedics UHE-CMTF45 Ultrasonic Humidifier with UV-C

IMPORTANT SAFETY INSTRUCTIONS

WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING.

DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
  • Always unplug the unit from the electrical outlet immediately after using and before cleaning.
  • DO NOT reach for a unit that has fallen into water. Unplug it immediately.
  • DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
  • DO NOT place or drop into water or other liquids.
  • DO NOT use water above 86°F.

WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:

  • Use this unit only for its intended use as described in this manual. DO NOT use attachments not recommended by Homedics; specifically, any attachments not provided with this unit.
  • NEVER drop or insert any object into any opening.
  • NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a Homedics Service Center for examination and repair.
  • Always unplug the unit when filling or moving the unit.
  • Ensure that your hands are dry when operating the controls or removing the plug.
  • DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to direct sunlight.
  • DO NOT carry this unit by the power cord or use the power cord as a handle.
  • To disconnect, turn all controls to the off position, then remove the plug from the outlet.
  • DO NOT use any other AC Adapter than what is supplied with the product. Use of any other AC adapter may damage the product and may increase risk of harm to user or property. Only AC Adapter bearing the Part Numbers specified in the Replacement part section of this manual should be used.

CAUTION: All servicing of this humidifier must be performed by authorized Homedics service personnel only.

SAVE THESE INSTRUCTIONS

CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.

  • This product is intended for household use only.
  • NEVER cover the unit while it is operating.
  • Always keep the cord away from high temperatures and fire.
  • Perform regular maintenance on the ultrasonic membrane.
  • NEVER use detergent to clean the ultrasonic membrane.
  • NEVER clean the ultrasonic membrane by scraping with a hard object.
  • DO NOT attempt to adjust or repair the unit. Servicing must be performed by professional or qualified personnel.
  • Stop using this unit if there is an unusual noise or smell.
  • Unplug this unit when not in use for a long period of time.
  • DO NOT touch the water or any parts of the unit that are covered by water while the uni is on or plugged in.
  • NEVER operate without water in the tank.
  • Only use water in the tank.
  • NEVER use any additive in the water.
  • Keep this unit out of reach of children. DO NOT allow children to use this unit without supervision.
  • DO NOT use outdoors. For indoor use only.

CAUTION: DO NOT place humidifier on furniture.
CAUTION: ALWAYS USE a waterproof mat or pad on wood floors.

ULTRASONIC HUMIDIFIER WITH UV-C

Ultrasonic Humidifier With Uv-c

CONTROL PANEL

Control Panel

HOW TO FILL

CAUTION: Before filling the tank with water, turn the power off and unplug the power adapter from the wall outlet and from the top cover.
NOTE: The convenient top-fill tank can be filled with a pitcher or at the faucet.

HOW AND WHY TO USE DEMINERALIZATION CARTRIDGES

The Homedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30–40 fillings. The cartridge may need to be replaced more often if you are using very hard water.

TO FILL WITH A PITCHER

  1. Before filling with water for the first time, remove 1 demineralization cartridge from the packaging and soak in water for 10 minutes. Remove the top cover and place in the water tank.
    To Fill With A Pitcher

  2. Fill the tank with clean, cool water or distilled water (if in an area with hard water) until the water level reaches the MAX fill line. NOTE: Do not fill past the MAX fill line.
    CAUTION: Never add essential oils or any other additives to the water tank. Even a few drops will damage the unit.
    To Fill With A Pitcher

TO FILL AT THE FAUCET

  1. Before filling with water for the first time, remove 1 demineralization cartridge from the packaging and soak in water for 10 minutes.
    To Fill At The Faucet

  2. To fill at the faucet, push the 2 side push lock buttons to remove the top\ cover.
    To Fill At The Faucet

  3. Fill the tank with clean, cool water or distilled water (if in an area with hard water) until the water is between the MIN & MAX fill lines.
    NOTE: Do not fill past the MAX fill line.
    CAUTION: Never add essential oils or any other additives to the water tank. Even a few drops will damage the unit.
    To Fill At The Faucet

  4. Place the soaked demineralization cartridge in the water tank.
    Replace the top cover making sure it is locked securely to the water tank.
    To Fill At The Faucet

ABOUT WHITE DUST

Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called “white dust.” The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.

HOW TO OPERATE

Insert single pin plug into the top of the humidifier, then plug the adapter into a 120-volt AC electrical outlet.

POWER BUTTON
Turns humidifier on/off.

Function IconMIST OUTPUT
Mist adjusts from the lowest output (1) to the highest output (3). To increase the mist output, press the mist output Function Icon button. The corresponding mist level will be lit on the display. Do not point the mist nozzle toward walls or furniture.

TIMER
Press the timer button until the desired auto-shutoff timer setting is displayed. The timer button will cycle through the following settings: 4, 8, 12 hours and off. To cancel the timer at any time, press the timer button until all LEDs are off.
NOTE: Always be sure the humidifier has a full tank of water prior to using the timer setting.

NIGHT-LIGHT/DISPLAY LIGHTS
Press the night-light button to turn the night-light on/off.

CLEAN REMINDER
The LED above the clean icon will illuminate red indicating it is time to clean the transducer/ultrasonic membrane. See cleaning instructions in the How to clean and care section. Press and hold the timer and night-light buttons until the red light turns off.

HOW TO USE THE OIL TRAY

CAUTION: Putting oil anywhere but the oil tray will damage the humidifier.
Use your favorite essential oil to deliver aroma into the air.

  1. The oil tray is located on the back of the humidifier near the top.
    How To Use The Oil Tray

  2. Push to open and remove the tray
    How To Use The Oil Tray

  3. Use the 1 preinstalled aroma pad in the oil tray (3 included).
    How To Use The Oil Tray

  4. Add 5–7 drops of essential oil to the pad. You may use more or less depending on personal preference.
    WARNING: Only place essential oil on the pad and NOT directly into the tray.
    How To Use The Oil Tray

  5. Place the oil tray back in its compartment and push to close. The scent will start automatically when the mist is turned on.
    How To Use The Oil Tray

NOTE: For use with the included Homedics essential oil pads only.
NOTE: Do not leave a filled essential oil pad in the oil tray if it will be out of use for a long period of time.

ARE ESSENTIAL OILS SAFE TO USE AROUND PETS?

We should always exercise caution when using essential oils around pets. Keep all essential oil and aromatherapy products (like diffusers) out of the reach of pets. Keep open bottles away from pets to avoid internal consumption. We do not recommend the topical use of essential oils on pets, as they have a strong sense of smell and cannot get rid of the oil if they don’t like it or it is disturbing them. When diffusing essential oils around pets, always diffuse in a well-ventilated area and leave an option for them to remove themselves from the space, such as leaving a door open. Every animal is different, so carefully observe how each animal responds when introducing an essential oil for the first time. If irritation occurs, discontinue the use of the essential oil. We recommend seeking medical attention if ingestion of essential oil occurs.

HOW TO CLEAN AND CARE

CAUTION: Before cleaning the unit, turn power off, unplug from the wall outlet and unplug the AC Adapter plug from the top of the humidifier.

CLEANING THE TRANSDUCER/ULTRASONIC MEMBRANE
The transducer/ultrasonic membrane must be cleaned to remove water mineral deposits when the red LED is illuminated above the clean transducer/ultrasonic membrane symbol. Failure to do so may cause reduced or no mist output.

  1. Push the 2 side lock buttons to remove the top cover.
    How To Clean And Care

  2. Pour out any water remaining in the tank.
    How To Clean And Care

  3. Open the transducer/ultrasonic membrane door and remove the float to access the transducer/ultrasonic membrane.
    How To Clean And Care

  4. Clean the transducer/ultrasonic membrane and float with a 50/50 mix of white vinegar and water on a cotton swab. Wipe off with a damp cotton swab.
    NEVER touch the transducer/ultrasonic membrane with your fingers; the natural oils in the skin can damage the surface.
    NEVER submerge the top in water or any other liquid.
    How To Clean And Care

  5. After cleaning, reassemble the humidifier, fill with water, plug in, and turn on.
    How To Clean And Care

  6. Press and hold the timer and nightlight buttons, until the red LED light above the clean symbol turns off.
    How To Clean And Care

HOW TO CLEAN AND CARE

TO CLEAN THE TANK
Remove the top cover from the humidifier.
Every day: Empty and rinse the inside of the tank before refilling.
Monthly or as needed: To remove any scale or buildup, use a 50/50 mixture of white vinegar and lukewarm water to clean the inside of the tank.

TO CLEAN THE OIL TRAY
Open the oil tray and remove the pad. Essential oil pads should be changed when switching to a different scent. If continuing to use the same scent, set the oil pad aside for reuse. Wipe the inside of the oil tray with a soft cloth. Place the essential oil pad back in the tray and close.
NOTE: Remove the essential oil pad when storing.

TO CLEAN THE SURFACE
Clean the surface of the unit with a soft, damp cloth.

STORAGE
BEFORE STORING
Clean the surface of the unit with a soft, damp cloth. Clean the water tank, float and the transducer/ultrasonic membrane following the cleaning instructions for each part.
Be sure to let all parts dry completely before storing. Clean the oil tray with a soft, damp cloth.

AFTER STORING
Rinse the tank with water prior to operating.

SPECIFICATIONS

ULTRASONIC TECHNOLOGY
This humidifier uses ultrasonic, high-frequency technology to convert water into a fine mist that is dispersed evenly into the air.

ELECTRICAL RATING
AC Adapter Input: 100-240 VAC, 50/60 Hz, 1.3 A.

UV-C TECHNOLOGY
This humidifier uses a non-replaceable, long life UV-C LED light to reduce E. coli bacteria, Staphylococcus aureus bacteria, A. niger mold, and P. citrinum fungus in the mist. Shown by independent laboratory testing. The UV light is working when the product is on.

AUTO-SHUTOFF PROTECTION
When the tank is empty, the unit will shut off automatically. The power/out of water LED will\ glow red.

CAPACITY
.97 gallons – 3.7 liters.

RUNTIME
Up to 35 hours. Runtime is based on setting the mist level on the low setting. Based on the natural humidity level in your home, the temperature of water you use, and the mist-level setting, you may experience longer or shorter runtimes.

ROOM SIZE
This humidifier is recommended for rooms up to 278 ft2/25.8 m2 based on AHAM HU-1-2016\ measurement as shown by independent laboratory testing.

QUIET OPERATION
22-24 dBA.

REPLACEMENT PARTS

To purchase genuine Homedics Replacement parts, go to the retailer where you purchased your Homedics Ultrasonic Humidifier with UV-C CMTF45, or visit www.homedics.com (US), www.homedics.ca (CAN).

WATER TANK
MODEL #: PP-UHECMTF45WTNK

DEMINERALIZATION CARTRIDGE
MODEL #: UHE-HDC4

AC ADAPTER
MODEL #:
PPUHECMTF45ADPT (White)
PPUHECMTF45ADP1 (Black)

AROMA PADS
MODEL #: UHE-PAD1

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
No power/no mist from spout
  • Unit is not plugged in
  • Unit is not turned on
  • No power at unit
  • Low water level
  • Transducer/ ultrasonic membrane needs cleaning
  • Float not installed

|

  • Plug unit in
  • Press the power button to turn the unit on
  • Check circuits and fuses or try a different outlet
  • Refill the tank with water
  • Follow Cleaning the Transducer/Ultrasonic Membrane instructions in the How to Clean and Care section
  • Install float

Peculiar odor|

  • Unit is new
  • If unit is in use, the odor may be a dirty tank or old tank water

|

  • Remove the tank and let it air out in cool, dry place for 12 hours
  • Empty the old water, clean the tank, and fill with clean water

Excessive noise|

  • Unit is not level
  • Low water level

|

  • Place unit on a flat, even surface
  • Check the water level; refill the tank if the water is low

White dust accumulation|

  • Hard water used
  • Demineralization cartridge needs to be replaced

|

  • Use distilled water and a demineralization cartridge
  • Replace demineralization cartridge

Red light illuminates above the clean symbol|

  • Transducer/ Ultrasonic Membrane needs cleaning
  • Clean reminder needs to be reset

|

  • Follow Cleaning the Transducer/Ultrasonic Membrane instructions in the how to clean and care section
  • Press and hold the timer and night-light buttons at the same time until the red light turns off

CAUTION: All servicing of this humidifier must be performed by authorized Homeric’s service personnel only.

SUPPLIER’S DECLARATION OF CONFORMITY

Product Description: ULTRASONIC HUMIDIFIER with UV-C
Model Number: UHE-CMTF45
Trade Name: Homedics

FCC Compliance Statement

This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

U.S. Contact Information
Company: Homedics, LLC.
Address: 3000 N Pontiac Trail, Commerce Township, MI 48390 8:30am-7:00pm EST Monday-Friday 1-800-466-3342

Homedics is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This product has been tested and compiles with the requirements for Federal Communication Commission, Part 18. Although this product is tested and compiles with FCC, it may interfere with other devices. If this product is found to interfere with another device, separate the other device and this product. Conduct only the user maintenance found in this instruction manual. Other maintenance and servicing may cause harmful interference and can void the required FCC compliance.

CAN ICES-001(B)/NMB-001(B)

2-YEAR LIMITED WARRANTY

Homedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of 2 years from the date of original purchase, except as noted below. Homedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to\ consumers and does not extend to Retailers.

To obtain warranty service on your Homedics product, contact a Consumer Relations representative for\ assistance. Please make sure to have the model number of the product available.

Homedics does not authorize anyone, including but not limited to Retailers, the subsequent consumer purchaser of the product from a Retailer, or remote purchasers, to obligate Homedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of Homedics.

This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved, and/or authorized, or repair of products damaged by these modifications is not covered under this warranty.

THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. Homedics SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL,CONSEQUENTIAL, OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS THAT ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, Homedics RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.

This warranty does not extend to the purchase of opened, used, repaired, repackaged, and/or resealed products, including but not limited to sale of such products on internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof that are repaired, replaced, altered, or modified, without the prior express and written consent of Homedics.

This warranty provides you with specific legal rights. You may have additional rights that may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you.

For more information regarding our product line in the USA, please visit www.Homedics.com. For Canada, please visit www.Homedics.ca.

CUSTOMERS SUPPORT

FOR SERVICE IN THE USA
[email protected]
8:30am–7:00pm EST Monday–Friday
1-800-466-3342

FOR SERVICE IN CANADA
[email protected]
8:30am–5:00pm EST Monday–Friday
1-888-225-7378

©2021–2023 Homedics, LLC. All rights reserved. Homedics is a registered trademark of Homedics, LLC.
Distributed by Homedics, LLC, 3000 N Pontiac Trail, Commerce Township, MI 48390 IB-UHECMTF45B Made in China

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Homedics User Manuals

Related Manuals