Specifications:

  • Model: OPC-478UD
  • Length: 52 cm (20.5 inches)
  • USB Cable Length: 1.5 m (4.9 feet)
  • Weight:
    • Programming Cable: 37 g (1.3 oz)
    • USB Cable : 49 g (1.7 oz)

Product Usage Instructions

Connecting the Cable and USB Driver Installation:

  1. Connect the PC to the Internet to download the USB driver. Make sure to sign in as the administrator.

Strain Relief:

Connect the programming cable to a USB port on your PC for data programming purposes.

COM Port Confirmation:

After the driver installation has been completed, confirm the availability of the driver and note the port number. The COM port number is required to set up the programming software. Make sure to sign in as the administrator and ensure no other applications are running.

Right-click on [Start], and then click…

FAQ

  • What is the purpose of the programming cable?
    • The programming cable is designed to connect an Icom transceiver or receiver to a PC for data programming using specific Icom programming software.
  • How do I dispose of the product?
    • In the European Union, electrical and electronic products like this cable must be taken to designated collection locations at the end of their working life. Do not dispose of them as unsorted municipal waste; follow the laws in your area for proper disposal.
  • What are the system requirements for using this programming cable?
    • As of July 2023, the cable is compatible with Microsoft Windows 11 (64-bit) and Microsoft Windows 10 (32-bit/64-bit), excluding Windows on ARM. An Internet connection is required for USB driver installation.

Important

SAVE THESE INSTRUCTIONS — These instructions contain important safety and operating details for the cable.
The programming cable is designed to connect an Icom transceiver or receiver and a PC for data programming using an Icom programming software.

Explicit definitions

Icom is not responsible for the destruction, damage to, or performance of any Icom or non-Icom equipment if the malfunction is because of:

  • Force majeure, including, but not limited to, fires, earthquakes, storms, floods, lightning, other natural disasters, disturbances, riots, war, or radioactive contamination.
  • The use of Icom products with any equipment that is not manufactured or approved by Icom.

Thank you for choosing this Icom product. READ ALL INSTRUCTIONS carefully and completely before using this product.

Precautions

WARNING! NEVER use or touch the cable with wet hands. This could cause an electric shock.

  • CAUTION : USE ONLY INDOORS! NEVER expose the cables to rain, snow, or any liquids.
  • NEVER let metal, wire, or other objects touch any internal part of the connectors.
  • NEVER place any heavy object on the cable, or pinch it.
  • DO NOT use harsh solvents such as benzene or alcohol when cleaning, as they will damage the cables.

Disposal

The crossed-out wheeled bin symbol on your product, literature, or packaging reminds you that in the European Union, all electrical and electronic products, batteries, and accumulators (rechargeable batteries) must be taken to designated collection locations at the end of their working life. Do not dispose of these products as unsorted municipal waste. Dispose of them according to the laws in your area.

About CE

Versions of the OPC-478UD which have the “CE” symbol on the product, comply with the essential requirements of the 2014/30/ EU directive for Electromagnetic Compatibility

System requirements

  • Operating System (OS)

Microsoft Windows 11 64-bit Microsoft Windows 10 32-bit/64-bit LExcept for Windows on ARM.

Others

A USB 1.1 or 2.0 port LAn Internet connection is required for the USB driver installation.
These instructions are based on using Windows 10.
The displayed dialog boxes, indications, or operations may differ slightly from the following instructions, depending on your operating system, its service pack level, and/or system settings.

Operating notes

DO NOT extend the USB cable. Using a USB cable other than the supplied may cause an error.

  • Ensure that your PC supports USB port operation by confirming the Universal Serial Bus controller is in the PC’s Device Manager.
  • Connect the cable directly to a PC’s USB port or to a self-powered USB hub.
  • Approximately 20 mA of current is required. Insufficient current capacity of the USB port can cause unstable programming operation and a data error

Specifications

All stated specifications are subject to change without notice or obligation.

Usable temperature range:

  • –10˚C to +60˚C (+14˚F to +140˚F)

Cable length (approximate):

  • OPC-478UD 52 cm (20.5 inches)
  • USB cable 1.5 m (4.9 feet)

Weight (approximate ):

  • OPC-478UD 37 g (1.3 oz)
  • USB cable 49 g (1.7 oz)

Supplied accessories

Connecting the cable and USB driver installation

  1. Connect the PC to the Internet to download the USB driver. LSign in as the administrator.
  2. Connect the programming cable to the USB cable, and then connect the USB cable to a PC USB port, as illustrated below.
    • The PC automatically installs the USB driver and starts the USB-to-Serial COM Port installation. LAttach the Ferrite EMI filter to the strain relief of the USB cable.

COM port confirmation

After the driver installation has been completed, confirm the driver’s availability and the port number.

The COM port number is required to set on the programming software.

LSign in as the administrator.

LConfirm no other applications are running.

  1. Right-click on [Start], and then click [Device Manager].
    • “Device Manager” is displayed.
  2. Click the “>” next to “Ports (COM&LPT).”
    • Confirm “USB Serial Port (COM✱)” is displayed. LIn this example, the COM port number is “3.” LSelect the COM port number in the programming software

NOTE:

  • If the COM port is not displayed, double-click [Other devices].
  • If the warning symbol “ ” with “FT232R USB UART” is displayed, the driver may not be properly installed. In such a case, manually install the USB driver. Refer to the next page for details.

Manual installation of USB driver

If the automatic USB driver installation is not successful, download the driver from the Icom website and manually install it on the “Device Manager” screen.

  1. Go to the Icom website.
    (https://www.icomjapan.com/support/)

    • In the “Firmware / Software”* menu, enter the model name and click the “Search” button to download the latest USB driver.
    • The menu name may be changed without notice.
  2. Unzip the file downloaded from the Icom website.

  3. Right-click [FT232R USB UART] displayed under “Other devices” on the “Device Manager” screen, and then click [Update driver].

  4. “How do you want to search for drivers?” is displayed. Click [Browse my computer for drivers].

  5. “Browse for drivers on your computer” is displayed. Click [Browse…].

  6. Select the unzipped file in step 2, and then click [OK].

  7. Click [Next] to start the installation.

  8. After the installation has been completed, “Windows has successfully updated your drivers” is displayed. Click [Close].

  9. Again, right-click [USB Serial Port], and then click [Update driver].

  10. Repeat steps 4 to 8, to install the “USB Serial Port.”

LConfirm the driver availability and the port number on the “Device Manager” screen.

American Communication System

Discover the Power of Communications™

http://www.ameradio.com

Icom and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United

Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries.

Microsoft and Windows are trademarks of the Microsoft group of companies.

All other products or brands are registered trademarks or trademarks of their respective holders.

Icom Inc.

1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan

© 2023 Icom Inc.

The below statement is for UKCA purposes only

United Kingdom Authorised Importer: Icom (UK) Ltd.
Address: Blacksole House, Altira Park, Herne Bay, Kent, CT6 6GZ, U.K.

To obtain the UKCA Declaration of Conformity, please contact Icom UK Limited by email at info@icomuk.co.uk or call + 44(0) 1227 741741.