Thank you for your purchase of the new, highly reliable AC Battery Charger, the BC-35 by ICOM.
Please read this Instruction Manual carefully to insure that you understand the charger’s functions thoroughly, and can get the best performance from it. It is designed for use with the Battery Packs for the various ICOM handheld transceivers. Namely, battery packs, IC-BP2, BP3, BP5, BP7 and BP8. For charging of installed batteries in the IC-BP4, please refer to the chapter titled Charging Operations.

BEFORE USE

This charger is for all Nickel-Cadmium Battery Packs used with ICOM’s handhelds, IC-BP2, BP3, BP5, BP7, BP8 and the IC-BP4 only if Nickel-Cadmium cells are installed. These slide-in packs can be charged separately, or while attached to the set.

CAUTION:
Do not attempt to charge the |C-BP4 with other than Nickel-Cadmium cells installed, to do so could cause serious injury. For charging the IC-BP4 please refer to Charging Operations.

INTRODUCTION

  1. All the battery packs for the handhelds have terminals on the base for charging of the same size, type, and construction. This charger, therefore, will operate with any of them.
  2. The charger is so designed that it is unnecessary to change settings or switches for rapid charge (1 – 1.5 hours, 1C-BP8: 2 ~ 3 hours) or normal charge (15 hours) packs. The charge rate is determined by the design of the packs.
  3. For battery capacities of 7.2V to 13.2V the BC-35 will charge automatically, using the proper current, governed by microswitches. ‘
  4. The charge current is controlled by the phase-angle, which reduces the interior heat of the charger.
  5. To avoid over-charge of the rapid-charge packs, |C-BP2, BP5, BP7 and BP8 charger automatically stops charging when they reach full charge.
  6. The charging lamp of the charger lights to indicate it is functioning and goes out when the rapid-charge packs are fully charged. The lamp will not light when any pack is inserted incorrectly.

DESCRIPTION OF CONTROLS AND CONNECTIONS

  1. Power Switch
    When the charger is connected to a wall outlet turns the charger on.

  2. Power Lamp
    Indicates power is on.

  3. Charge lamp
    Indicates charging is underway, goes outwhen charging of rapid-charge packs is completed.

  4. Insertion slot for battery packs.

  5. Charging terminal
    Correspond to the terminals on the bottom of the battery packs.

  6. Micro switches.
    Since the current and capacity for each battery pack is different, these micro switches select the proper factors for each one.
    Product Overview

CHARGING -OPERATIONS

CHARGING PERIOD AND PACKS ACCEPTED BY THE BC-35

Listed below are the charging period and specifications for various packs.

Type| Modal| Cheered (Approx)| Voltage| Interna call| Height of the pack (mm)| Replaceable Batteries
---|---|---|---|---|---|---
Rapid| IC-BP2| 1~15H| 72V| N425ARx 6| 39| No
Rapid| IC-BPS| 1~ 1.5H| 108V| N-425ARx 9| 60| No
Rapid| IC-BP7| 1~15H| 132V| N-450ARx11| 80| No
Rapid| IC-BP8| 2~3H| 84V| N-BOOARX 7| 80| No
Normal| IC-BP3| 15H| 8.4V| N-250AA x 7| 39| No
Normal| IC-BP4*| 15H| 7.2v| AA type 450m AH x 6| 49| Yes

When AA type 450mAH Nickel-Cadmium batteries are installed.

DO NOT ATTEMPT TO CHARGE REGULAR ZINC OR ALKALINE BATTERIES!

Operation of the charger is quite simple, but it is very important that you understand the battery packs that are suitable, please carefully consult the table above prior to charging any battery pack.

WHEN TO CHARGE

Nickel-Cadmium battery packs offer stable and accurate voltages, but due to their characteristics, just prior to being exhausted there is a sudden voltage drop. When sudden voltage drop occurs, it is important to stop using the batteries and recharge them. |f charging is not done the battery life is shortened, and it is possible that polarity will be reversed.

Stop using the battery pack when the handheld’s transmit LED flickers or does not light when transmitting, or if the battery condition indicator is displayed. When it is obvious that the transceiver is not receiving power from the pack, STOP to use the transceiver, and recharge the battery pack. This is also true when the transceiver’s reception is weak, or if the normal rushing noise is low.

Newly purchased battery packs and those that have not been recharged for two months, or longer, should be charged. New battery packs are shipped from the factory without charging.

CHARGING PERIOD

The necessary time for full charge is 1 to 1.5 hours for the rapid-charge packs (IC-BP8: 2~ 3 hours), and approximately 15 hours for the normal-charge packs.

Rapid-charge packs are charged at the full charge current of 600mA. The charge lamp will go out when these packs reach full charge.

Normal-charge packs are charged at 25mA for the IC-BP3 and 456mA for the IC- BP4 (with Nickel-Cadmium batteries installed). A 15 hour charge is recommended to insure that all the batteries in the pack are evenly charged, an unbalanced charge will shorten battery life.

AMBIENT TEMPERATURE RANGES

Normal-Charge Packs: 0° ~ +45°C.
Rapid-Charge Packs: +10° ~ +40°C.

As can be seen from the above, charging is possible over a wide temperature range. Keeping within those limits will insure 100% charge and it is recommended that you keep within the limits. The rapid-charge packs have an internal sensor that will stop the charge if out of the these limitations.

PRECAUTIONS

It is possible to charge the packs while they are attached to the transceiver, but be sure that the set’s power switch is turned off.

When charging the packs alone, be sure that the terminals on the top are not shorted, use the insulator strip provided to prevent this.

Penlite (AA type) Nickel-Cadmium batteries for IC-BP4, which will appear as a white crystal-like substance oozing from them at their ends. This will causé poor connection. Burnishing the springs and clips inside the IC-BP4 occasionally is important.

DO NOT ATTEMPT TO CHARGE OTHER THAN NICKEL-CADMIUM CELLS IN THE BC-35! READ THE MANUFACTURER’S INSTRUCTIONS AND THE CHAPTER OF THIS MANUAL ON CHARGING OPERATIONS CAREFULLY!

Nickel-Cadmium batteries can be normally recharged about 300 times. It is not possible to replace the cells in the IC-BP2, BP3, BP5, BP7 and BP8. All these battery packs are offered for sale separately.

Battery packs are not charged before shipping, charge before using.

Before installing Penlite Nickel-Cadmium cells in the IC-BP4 check with the dealer to find if they have been pre-charged.

While charging the BC-35 may cause interference to adjacent radio equipment, locate the charger well away from such equipment.

The optional IC-DC1 cannot be used in conjunction with the BC-35 for charging, it can be inserted and used as a stand for the ICOM handhelds.

CHARGING PROCEDURES

Connect the BC-35 to a wall outlet. Turn on the power switch – the Power lamp will light.

Set the battery pack into the charger with the model label to your right, the Charging Lamp will illuminate when the pack is properly inserted.

As noted before the entire handheld can be inserted, be sure that the transceiver’s power switch is off. Do not attempt to operate the set while it is in the charger.
Charging Procedures

POWER/CHARGING LAMPS

The power lamp will light when the power switch is turned on, but the charging lamp will not be lighted under the following circumstances:

The battery pack is inserted incorrectly.

The springs and terminals of the |C-BP4 are fould with battery leakage, or the cutouts in the base of the pack are not clear.
Charging of a rapid-charge pack is completed, and batteries have not cooled (it takes approximately 30 minutes for the batteries to cool.)

NOTE:
The charging lamp will not go off at the end of normal charge (15 hrs.) the pack should be removed after that time interval.

When a battery pack is fully charged it is important that it not be re- inserted in the charger to do so can damage the cells and shorten their life

SPECIFICATIONS

Charging currents:

IC-BP2,BP5andBP7 ……………. 600mA for 1- 1.5 hours
IC-BP8 . o 600mA for 2 ~ 3 hours
ICBP3 iinswivisiamincsmesvawsns 25mA for 15 hours
JCBPL .. ovomus msm s mssmsmssine 45mA for 15 hours (applies only to Nickelv Cadmium batteries installed) Temperature Limitations: 1C-BP2, BP5, BP7 and BP8 +10°C ~ +40°C. IC-BP3 and IC-BP4 0°C ~ +45°C.

The IC-BP2, BP5, BP7 and BP8 have built-in temperature sensors to prevent overcharge. Power Requirement: 117V or 240V AC, 50/60Hz.
Charging currents

ICOM INCORPORATED 1-6-19, KAMI KURATSUKURI, HIRANO-KU, OSAKA JAPAN

ICOM Logo

Documents / Resources

| ICOM BC-35 AC Battery Charger [pdf] Instruction Manual
BC-35 AC Battery Charger, BC-35, AC Battery Charger, Battery Charger, Charger
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ICOM User Manuals

Related Manuals