Read before you use
This device should never be used to relieve undiagnosed pain. Before treating any symptoms of pain, you should consult your doctor.
Warnings
- Never use this device near the heart, around the mouth, or on diseased skin.
- Do not use this device in places with high humidity such as the bathroom.
- May need to use under the supervision of a physical therapist.
- For external use only.
- Long-term stimulation and use at the same site may cause skin discomfort. Consult a dermatologist if skin discomfort persists.
- Consult a doctor before you use this device if you receive other medical treatments.
- Do not disassemble this device.
- Do not use the device while sleeping, driving, bathing, operating machinery, or during any activity in which involuntary muscle contractions which may cause undue risk of injury.
- Do not let the device come in contact with any metal object, such as belt buckle or jewelry.
- Do not use the device over twice a day on the same place of your arms and/or legs.
- Caution should be used with the following conditions:
- Have had a recent surgical procedure where muscle contraction may disrupt the healing process.
- Over areas of the skin that lack normal sensation.
- Gel pad placement and stimulation settings should be based on the guidance of the Instruction Manual.
- The long-term effects of electrical stimulation are currently unknown but is rapidly advancing.
- The device may cause lethal rhythm disturbances to the heart in susceptible individuals.
- Device is ineffective for pain of central origin, including headaches.
- This device has no curative value; it is a symptomatic treatment and as such suppresses the sensation for pain which would otherwise serve as a protective mechanism on the outcome of clinical process.
- Electronic equipment such as EKG monitors and ECG alarms may not operate properly when device is in use.
- The user must keep the device out of the reach of children.
- Stimulus delivered by this device may be sufficient to cause electrocution or burn and it may cause a cardiac arrhythmia.
- Possible allergic reaction to tape or gel may exist. Possible skin irritation and electrode burns are potential adverse reactions. If skin irritation persists, discontinue use and consult your physician.
- Apply stimulation only to normal, intact, clean, healthy skin.
- If your pain does not improve, becomes more than mild, or continues for more than five days, stop using the device and consult with your physician.
- Not for use by or on persons under the age of 18 years old.
- Stop using this device if you experience a tingling or numbing sensation, or other discomfort on the skin.
Do not use if you,
- Have pacemaker, metal implant, insulin pump or any other implant in the body.
- For patients with known myocardial disease or arrhythmia, the device should be used only with consultation and evaluation by a specialized physician.
- Do not apply any electrode placement that causes current to flow through the head.
- Do not use device on the eyelids. Do not place electrodes directly over the carotid sinus nerves or arteries, and laryngeal or pharyngeal muscles.
- Do not apply device for undiagnosed pain syndromes until etiology is established.
- Have seizure disorder, unless consulting with a physician, example: epilepsy.
- Are pregnant or menstruating.
- Have cancer.
- Had arm or leg operations before, and the pain is caused from past surgery or accident.
- Are suffering from a metabolic arthritis.
- Device should not be applied over swollen, infected, inflamed areas, or skin eruptions, ex. phlebitis, thrombophlebitis, varicose vein, etc.
- Device should not be applied over, or in proximity to, cancerous lesions.
- Have arm and/or leg skin conditions of:
- Acutely or chronically diseased (injured or irritated) skin
- Hypersensitive skin
- Allergy with the gel pad
- Scars
- Healing wounds
- Rashes
- Inflamed skin
- Bruises
- Swelling
- Hemorrhage following acute trauma or fracture after use
The proper use of this device is important to obtain temporary pain relief. Please take the next few minutes to read this manual carefully and learn the correct operation of this easy-to-use equipment.
This Rapid Relief device is indicated for temporary relief of pain associated with sore and aching muscles in the arms and/or legs as a result of strain from exercises or normal household and work activities.
WHAT IS RAPID RELIEF?
Rapid Relief is a TENS device – TENS stands for Transcutaneous Electrical Nerve Stimulation. The device emits controlled micro-electric currents called impulses through skin to interact with nerves for temporary pain relief.
The pain relieving effect comes from blocking the nerve pathway transmitting pain signals.
INDICATIONS FOR USE
Arm & Leg Pain
Place this device where you appear to have pain. For optimum result, move device to the other spot indicated on the image on the left, after finishing 20 minute cycle.
BATTERY AND GEL PAD ASSEMBLY
-
Use a coin or small device to turn the battery door to the OPEN position.
-
Flip open battery cover with a pin.
-
Insert battery provided “+” side up (CR2032 Lithium battery only).
-
Close and lock battery cover.
-
Remove blue film from the gel pads.
-
Place exposed side onto the unit and press firmly with fingertips to adhere.
-
Remove clear film from the back of the gel, pulling slowly to ensure the gel stays in place.
-
Your unit is now ready to place where it hurts.
Note: Clean skin area before applying.
HOW TO OPERATE
- Press and hold + button for 3 seconds to power the unit ON and listen for the beep. Note: The unit will not operate if it is not in contact with your skin.
- Press + button again to activate device. Continue to press the + button until you feel the sensation of the impulses.
- Use +/- button to adjust intensity level, note there are 15 levels.
- The device automatically powers off after 20 minutes, or press and hold – button for 3 seconds to power OFF.
Note:
- Battery will need to be replaced if the device no longer makes a beep sound or sends any electric impulses. Please check the troubleshooting section for additional issues with beeping.
- Device only works when in contact with the skin. When the device is not in contact with the skin, the device will not activate the impulses.
- After use, always place the device into the provided carry case protecting the gel pad after use.
- Smart Contact Detection automatically sends audible alerts when the gel pads are not securely fixed to the skin.
- When power is on, intensity level is set to 0 for safety purposes. Press the + button again to activate and increase intensity
MAINTENANCE
Storage of the device:
- Keep the device away from children.
- Remove the battery if the unit will not be used for more than 10 days.
- Place the device into the protective carry case to protect the adhesive gel pads and device.
- Do not store the unit under high temperature, high humidity, direct sunlight, exposed environment or where there is a lot of dust or corrosive gas.
Care for Device
- To avoid damage to the device:
- When removing the device from the carry case pull out gentle and slow.
- Do NOT twist the device.
- Do NOT pull on the device pads strongly, or pull outward from the device center.
- Do NOT push or pull on the device center, this can deform the device causing operation issues.
- Do NOT disassemble any part of the device.
Care for gel pads:
- If the adhesive gel pads get dirty or less sticky you can prolong the life for additional uses by cleaning it. With a drop of water on your finger, rub the water over the surface of the gel and allow it to dry.
- Always store the gel pads in the protective case after use. Do not store it in other areas, or adhere the gel to a surface other than your skin or the inside of the protective case as this can damage the gel and reduce the life of it.
- Be sure the skin is clean before the gel pads are placed on the body.
- Always store in a cool, airy area away from direct sun light.
Replacing the gel pads:
- To remove the gel pad carefully roll the gel upwards with your fingers until the entire pad has lifted off. Note: Do not use fingernails or tools as they can damage the unit.
- Repeat on other side.
- Clean the device with a drop of water on your finger to remove left over residue. Allow to dry.
- Place new pads onto the unit following steps 5-8 in the Battery and Gel Pad Assembly section.
CAUTION
-
If the unit is not functioning properly or causes discomfort, stop using it immediately.
-
Press and hold the – button for 3 seconds to turn the device OFF before removing the device from the skin.
Note: If removed from skin before turning unit off, you may receive a small zap on your fingers that may be uncomfortable. -
If the gel pads are dirty, dry or sticking to hair, it might cause skin discomfort. Please replace it immediately.
BATTERY PRECAUTIONS & DISPOSAL
- Use only the size and type of battery specified.
- When installing the battery, observe proper +/- polarities. Incorrect installation of the battery may cause damage to the unit.
- Do not dispose of battery in fire. Battery may explode or leak.
- If the unit is not going to be used for a long period of time, remove the battery to prevent damage due to possible battery leakage.
- Remove used battery promptly.
- Dispose of properly in accordance with all state, province and country regulations.
TROUBLESHOOTING
Product Specifications
Homedics HW-P100 Rapid Relief for Arms and Legs User Manual and Warranty
Information – Download [optimized]
Homedics HW-P100 Rapid Relief for Arms and Legs User Manual and Warranty
Information – Download
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>