Specifications:

  • Power consumption: 20W-79W
  • Nominal current: 0.1A-0.35A @230Vac
  • Power supply: 220-240VAC 50/60Hz
  • Inrush current: Varies
  • Power factor: 0.87-0.97
  • Electrical class: I
  • Weight: 2.1 Kg-5.6 Kg
  • Operating temperature: Not specified
  • IP rating: IP67
  • IK rating: IK09-IK10
  • Dimensions: Vary by model

Product Usage Instructions:

Installation

– This product must be installed in accordance with applicable
national and local electrical and construction codes by a person
familiar with the construction and operation of the product and the
hazards involved.

– Do not stare at the operating light source.

– The fixture might be damaged by excess voltage. The
installation of an overvoltage protection device on the electrical
system (SPD) is recommended to reduce the risk of damage.

Maintenance

– Connect the fixtures to each other only when disconnected from
mains.

– Never leave cables and connectors unconnected or unprotected
for long periods.

– Disconnect power before installing or servicing to avoid
electrical shock.

– Apply to qualified staff for any maintenance service not
described in this instructions manual.

Powering the Unit

– Check voltage and frequency before powering the fixture. Do
not exceed fixture specified voltage.

– Before powering the unit, ensure to use cables and connectors
with proper section and length, according to its power
consumption.

Safety Precautions

– Do not handle the unit with wet hands or in wet
environments.

– Fix the projector by using screws, hooks, or other adequate
supports that can bear its weight.

– If the external flexible cable of this appliance is damaged,
it must only be replaced by the manufacturer, its assistance
service, or equivalent qualified personnel to avoid hazards.

Positioning

– The luminaire should be positioned so that prolonged
observation of the luminaire at a distance of less than 2 meters
(6.56 ft) is not expected.

FAQ:

Q: What should I do if the fixture is damaged by excess

voltage?

A: Installing an overvoltage protection device on the electrical
system (SPD) is recommended to reduce the risk of damage.

Q: Can I connect the fixtures while they are still connected to

the mains?

A: No, connect the fixtures to each other only when disconnected
from mains to ensure safety.

Q: What should I do if the external flexible cable is

damaged?

A: It must only be replaced by the manufacturer, its assistance
service, or equivalent qualified personnel to avoid hazards.

“`

Parade

User Manual

L1 – L2- L3 – L4

Rev. 6.0

551091

Date: 23/09/2023

Code
Power consumption Consumo di energia
Nominal current Corrente nominale
Power supply Alimentazione elettrica
Inrush current Corrente di spunto
Power factor Fattore di potenza
Electrical class Classe elettrica
Weight / Peso
Operating temperature Temp. funzionamento
IP rating / Grado IP
IK rating / Grado IK

Parade L1
AL5060 – AL5061 (PE)
20W (RN) 19W (DW) 19W (W)
0.1A (RN) 0.1A (DW) 0.1A (W) @230Vac

Parade L2
AL5065 – AL5066 (PE)
38W (RN) 38W (DW) 37W (W)
0.17A (RN) 0.17A (DW) 0.17A (W) @230Vac

Parade L3
AL5070 – AL5071 (PE)
58W (RN) 57W (DW) 56W (W)
0.26A (RN) 0.26A (DW) 0.25A (W) @230Vac

220-240VAC 50/60Hz

Parade L4
AL5075 – AL5076 (PE)
79W (RN) 76W (DW) 75W (W)
0.35A (RN) 0.34A (DW) 0.34A (W) @230Vac

23.42 A @240VAC, 25°C

27.5 A @240VAC, 25°C

cos.= 0.87

cos.= 0.94

cos.= 0.95

cos.= 0.97

2.1 Kg IK09

I

3.1 Kg

4.4 Kg

-40°C to +50°C ( -40°F to 122°F )

IP67

IK10

IK09

5.6 Kg IK10

Dimensions / Dimensioni Parade L1

70 mm [2.7″]

318 mm [12.5″]

76 mm [3″]

70 mm [2.7″]

Parade L2 610 mm [24″] Parade L3 914 mm [36″] Parade L4 1219 mm [48″]

Griven S.r.l. – Via Bulgaria, 16 46042 Castel Goffredo Mantova – Italy

Tel. +39.0376.779483 E-mail: sales@griven.com Web: www.griven.com

© Copyright Griven 2020 – GRIVEN S.r.l. is continuously developing and improving all its products. We reserve the right to change specifications without prior notification

page 1 of 8

Important notices – Avvisi importanti

– This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
– Do not stare at the operating light source.
– The fixture might be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system (SPD) is recommended for reduce the risk of damage.
– The use of an adequate magnetothermic switch along the power supply line is recommended.
-Connect the fi xtures to each other only when disconnected from mains. – Never leave cables and connectors unconnected or unprotected for long periods.
– Disconnect power before installing or servicing to avoid electrical shock.
– Disconnect power before any connection operation.
– Check voltage and frequency before powering the fixture. Do not exceed fixture specified voltage. – Do not handle the unit with wet hands or in wet environments.
– Apply to qualified staff for any maintenance service not described in this instructions manual.
– Do not exceed the maximum quantity of fixtures per line in order to avoid power surges.
– Before powering the unit, ensure to use cables and connectors with proper section and length, according to its power consumption.
– Fix the projector by using screws, hooks or other adequate supports that can bear its weight.
– If the external flexible cable of this appliance is damaged, it must only be replaced by the manufacturer, its assistance service or equivalent qualified personnel in order to avoid hazards.
– Integrated temperature control, the projector reduces power when Ta >35°C.
– The luminaire should be positioned so that prolonged observation of the luminaire at a distance of less than 2 meters (6.56 ft) is not expected.

– Questo prodotto deve essere installato secondo le normative locali, da personale specializzato. La mancata osservanza delle istruzioni di installazione può portare a situazioni di pericolo all’incolumità della persone.
– Non fissare la sorgente luminosa durante il suo funzionamento.
– Apparecchiatura sensibile alle sovratensioni. Si consiglia l’installazione di un dispositivo di protezione delle sovratensioni (SPD) sull’impianto elettrico per attenuare l’intensità di questi fenomeni proteggendo gli apparecchi dal rischio che vengano danneggiati.
– E’ consigliato l’uso di un adeguato interruttore magnetotermico/differenziale sulla linea di alimentazione.
– Collegare tra loro i proiettori solo quando nessuno di essi è collegato alla rete elettrica.
– Non lasciare mai per lungo tempo agli agenti atmosferici cavi e connettori non collegati o non protetti.
– Togliere l’alimentazione prima di effettuare qualsiasi operazione all’interno dell’apparecchiatura.
– Togliere l’alimentazione prima di effettuare qualsiasi operazione di connessione tra gli apparecchi.
– Prima di connettere l’apparecchio alla rete elettrica, verificate la compatibilità di tensione e frequenza.
– Non maneggiate il prodotto con mani bagnate o in presenza di acqua.
– Rivolgersi ad un tecnico qualificato per qualsiasi operazione di manutenzione ordinaria non descritta nel presente manuale.
– Non superare il numero massimo specificato di apparecchi per linea per evitare pericolori sovraccarichi di corrente.
– Prima di effettuare le connessioni verificare la portata dei cavi / connettori e la lunghezza dei cavi tenendo conto dell’assorbimento del prodotto.
– Fissare il proiettore con viti, ganci o altri supporti in grado di sostenerne il peso.
– Se il cavo flessibile esterno di questo apparecchio vienne danneggiato, deve essere sostituito esclusivamente dal produttore, dal suo servizio di assistenza o da personale qualificato equivalente, al fine di evitare pericoli.
– Controllo della temperatura integrato, il proiettore reduce la potenza ad una Ta >35°C
– l’apparecchio di illuminazione dovrebbe essere posizionato in modo che non sia prevista un’osservazione prolungata dell’apparecchio ad una distanza inferiore a 2 metri.

CAUTION: Prolonged staring at the LED source should be avoided by placing the fixture in a proper position.
WARNING ! Fixing and connecting operations must mandatorily be carried out by qualified personnel only !

ATTENZIONE! Fissare la sorgente LED per un periodo prolungato va evitato posizionando l’apparecchio nella posizione appropriata.
ATTENZIONE ! Le operazioni di fissaggio e collegamento devono essere eseguite solo e obbligatoriamente da personale qualificato!

WARNING ! Make sure that power supply is off before connecting or disconnecting fixtures !

ATTENZIONE ! Assicurarsi che l’alimentazione sia spenta prima di collegare o scollegare i dispositivi!

The possibility of reusing some electrical parts of the device is subject to the total responsibility of the user. The label shows the symbol indicated in Legislative Decree n.49 of 14 March 2014 which transposes Directive 2012/19 / EU, which indicates the need to dispose of the product in separate waste, specifically in electrical waste. and electronic. Refer to the waste collection center located in your area.

La possibilità di riutilizzare alcune parti elettriche del dispositivo è subordinata alla totale responsabilità dell’utilizzatore. Nell’etichetta è stato riportato il simbolo indicato nel D.lgs n.49 del 14 Marzo 2014 che recepisce la direttiva 2012/19/UE, il quale indica la necessità di smaltire il prodotto nei rifiuti differenziati, nello specifico nei rifiuti di tipo elettrico ed elettronico. Fare riferimento al centro di raccolta rifiuti situato nella Vostra zona.

Replaceable control gear by a professional

Alimentatore sostituibile da un professionista

Replaceable (LED only) light source by a professional

Sorgente luminosa (solo LED) sostituibile da un professionista

This product contains a light source of energy efficiency class:

Questo prodotto contiene una sorgente luminosa di classe di efficienza energetica:

3000K 4000K Dynamic White RGBW 4000K

F

F

E

F

page 2 of 8

Parade L – Rev. 6.0

Connection – Connessione
“C” Type cable ( Hybrid cable + connectors )
“M” Type cable (Hybrid cable without connectors – DMX)
“M” Type cable ( Hybrid cable without connectors – DALI)
Parade L – Rev. 6.0

POPWOWEERR ++DDMMX XOUOTUT PPOOWWEERR+ +DMDXMINX IN

A=DMXB=DMX+ C=common 1=N 2=L 3=GND

Blue= N (Neutral) Yellow/Green=GND Brown=L (Line) RED= DMX + WHITE=COMMON BLACK= DMX –
Blue= N (Neutral) Yellow/Green=GND Brown=L (Line) RED= DMX + WHITE=COMMON BLACK= DMX –

POWER + DMX IN/OUT POWER + DMX IN/OUT

Blue= N (Neutral) Yellow/Green=GND Brown=L (Line) GREY= DALI +
BLACK= DALI –
Blue= N (Neutral) Yellow/Green=GND Brown=L (Line) GREY= DALI +
BLACK= DALI –

POWER + DALI OUT
POWER + DALI IN
page 3 of 8

Installation – Installazione
Size 8 (ISO) socked Hex key
Size 10 (ISO) Hex key

3 0

Ø6
L1 = from 90 to 319 L2 = from 90 to 610 L3 = from 90 to 915 L4 = from 90 to 1220
-90°

Size 10 (ISO) Hex key
+90°

Size 4 (ISO) Allen key

This side to the wall

For 3G applications, consider

the distances informed bellow:

A

B

Parade L-1 (A= 8cm, B= 8cm) Parade L-2 (A= 15cm, B= 15cm) Parade L-3 (A= 22,5cm , B= 22,5cm) Parade L-4 (A= 30cm , B= 30cm)

Polar features (only on Polar Edition fixtures )
The POLAR Edition is fitted with a thermal glass which is particularly useful for outdoor applications. In fact, by warming up, the glass melts ice and snow which might interfere with the projection. When the projector is on, if required by the weather conditions, the glass is automatically warmed up.
WARNING: If the projection is to be started at a definite time, take care to defrost the glass in advance so that the LEDs can be lit at the time required. WARNING: At very low temperatures (below -20° C), it is recommended to let the fixture always powered and to switch on the LEDs when needed.
page 4 of 8
Parade L – Rev. 6.0

IR Remote Control operations / Operazioni del telecomando IR
The fixture must be configured only by using AL1321 IR remote control ( sold separately ) or via any DMX-RDM compatible controller.

LOGIN

DMX MODE

DMX MODE SETTING DMX ADDRESS SETTING

5′ inactivity = Automatic LOGOUT
Enter the”IR” value on DMX chart under “MODE” column ( eg: IR=4, press button 4 ).
001~512

FLASH
= OK
FLASH FLASH
= OK
FLASH FLASH FLASH
= OK

MASTER/SLAVE AUTOMATIC
¹ MODE
TO BE USED ONLY
WITH DMX MODE #1

AUTOMATIC/MASTER

Green-Cyan-Blue-MagentaRed-Yellow-White.

SLAVE FIXTURE SETTING

001

FIXED COLOR MODE
(RGB-RGBW-DW)
TO BE USED ONLY WITH DMX MODE #1
DIMMER MODE
(Monochromatic)
TO BE USED ONLY WITH DMX MODE #1

RGB
1 = RED 2= GREEN 3 = BLUE
DW 4 = COLD WHITE 5 = WARM WHITE

RGBW
1 = RED 2= GREEN 3 = BLUE 4 = WHITE

LOGOUT

OK

5″10″20″ 40″

FLASH

2 3 x FLASH

x FLASH

4x FLASH

40″ 20″ 10″ 5″

4 3 x FLASH

x FLASH

2x FLASH

FLASH

FLASH FLASH FLASH
= OK

0%100%

100%0%

RESET

OK

Reset to default settings

WIRELESS ²

1 = Unlink 2= LED wireless status ON 3= LED wireless status OFF

¹ WARNING ! In this mode, no other DMX control device must be present along the line. ² Only on wireless fixtures

Parade L – Rev. 6.0

page 5 of 8

DMX Chart

RGBW

Mode

1 IR=4

2 IR=5

Channel
1 2 3 4 1 2 3 4 5 1 2 3 4

3

IR=6

5

6
1 2 3 4

4 IR=7

5

6

1

2

3

5

4

IR=8

5

6

7

8

Function
0-100% Red 0-100% Green 0-100% Blue 0-100% White 0-100% Red 0-100% Green 0-100% Blue 0-100% White 0100% Dimmer 0-100% Red 0-100% Green 0-100% Blue 0-100% White
0% Dimmer 100-0% Dimmer 100% Dimmer
No Strobo 0-100% Strobo 100% Strobo
0-100% Red 0-100% Green 0-100% Blue 0-100% White NO FUNCTION
2700K 2700K3000K
3000K 3000K3500K
3500K 3500K4000K
4000K 4000K4500K
4500K 4500K5000K
5000K 5000K5500K
5500K 5500K6000K
6000K 0100% Dimmer
0-100% Red 0-100% Red fine 0-100% Green 0-100% Green fine
0-100% Blue 0-100% Blue fine
0-100% White 0-100% White fine

Value
0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255
0-5 6-250 251-255
0-5 6-250 251-255 0-255 0-255 0-255 0-255
0-5 6-7 8-40 41-42 43-75 76-77 78-110 111-112 113-145 146-147 148-179 180-181 182-214 215-216 217-249 250-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255

Parade L – Rev. 6.0

Mode Channel

Function

1

0-100% Red

6

2

IR=9

3

(Default)

4

0-100% Green
0-100% Blue
0-100% Calibrated White ( Affects RGB channels )

Note: in absence of DMX signal the LEDs will remain OFF.

DW (Dynamic White)

Mode

1 IR=2 (Default)

Channel
1
2

Function
0%100% Warm white
0%100% Cold White

1

2 IR=3

2

3

0%100% Warm white 0%100% Cold white
0%100% dimmer

1

0%100% Warm white

3

2

IR=3

3

0%100% Warm white fine 0%100% Cold white

4

0%100% Cold White fine

Note: in absence of DMX signal the LEDs will remain ON.

Monochromatic version

Channel

Function

1

0%100% dimmer

Note: in absence of DMX signal the LEDs will remain ON.

Value
0-255 0-255 0-255 0-255
Value
0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255
Value
0-255

Indipendent pixels Nelle versioni “Indipendent pixels” le funzioni citate nelle precedenti tabelle vengono ripetute per il numero di moduli dell’apparecchio. Es. Parade L3 RGBW nella modalità #1 impegna 12 canali. In the “Independent pixels” versions, the functions mentioned in the previous tables are repeated for the number of modules in the device. E.g. Parade L3 RGBW in mode #1 engages 12 channels.
RDM functions When operating in DMX mode the fixture can accept the following RDM commands:
· Discovery: Upon request of the RDM controller, the fixture signals its own presence (the RDM controller will display the fixture on a list).
· DMX address reading and setting. · Channels number reading and setting. · On / Off identification: This command is used to identify the
fixture you want to get access to (the identification happens by switching on all the LEDs at full intensity). · Manufacturer: it displays the name of the manufacturer (Griven). · Model description: it displays the fixture’s model. · Software version description: it displays the current version of the firmware. · Temperature: it displays the LEDs operating temperature value.
page 6 of 8

DALI supported commands

Command # 1 2 3 4 5 6 7 8
16…31 32 33 42 43 45 46 47
64-79 80-95 96…111 112…127
128 144 145 151 152 153 154 155 160 161 162 163 164 165 176…191 192 193 194 195 196

Description Off Up (Fade rate) Down (Fade rate) Step Up ( Increment arc power level ) Step Down ( Decrement arc power level ) Recall MAX level Recall MIN level Step down and off ( Decrement arc power level if at min level turn down ) Go to scene 0…15 Reset ( DALI factory default parameters ) Store actual level in the DTR Store DTR as MAX level Store DTR as MIN level Store DTR as Power On level Store DTR as Fade Time Store DTR as Fade Rate Store DTR as Scene 0…15 Remove from Scene 0…15 Add to Group 0…15 Remove from Group 0…15 Store DTR as Short Address Query Status Query Ballast Query Version Number Query Content DTR Query Device Type Query Physical Minimum Level Query Power Failure Query Actual Level Query Max level Query Min level Query Power On level Query System Failure level Query Fade Time/Fade Rate Query Scene level Query Groups 0…7 Query Groups 8…15 Query Random Address High Query Random Address Middle Query Random Address Low

DALI version: 1, Device Type: 6(LED), Physical Min Level: 1 (0.1%)

page 7 of 8

Parade L – Rev. 6.0

Configuration examples / Esempi di configurazioni

A

dmx

B

D

I

C

A

dmx

A

B

C

A
dmx
B C A

A – Power Input CE ver. 220-240 Vac – ver. 120 & 277 Vac B – DMX/RDM Controller C – Start Line Box – AL5058C with connectors / AL5058M without connectors D – Parade L-1 , L-2 , L-3 , L-4 , L-2 Recessed , L-3 Recessed E – Connection Cable – AL8264 L=1m AL8265 L=2m AL8266 L=3m AL8267 L=5m AL8268 L=10m F – DMX Terminator – AL5169 G – Repower Box – AL5167C with connectos / AL5167M without connectors H – DMX Junction Box – AL5059C with connectors / AL5059M without connectors I – DMX Cable – AL0512

Operating modes / Modalità operative
DMX Mode
Addr. 001
Power input B
DMX
Example with fixtures set at 4 DMX channels

Addr. 005

E

Max. 10 A Use a DMX repeater on each 32nd

F

per

daisy chain the total DMX LINE length exceeds

1000 ft (300m)

F

G

Max. 10 A Use a DMX repeater on each 32nd

per

daisy chain the total DMX LINE length exceeds

1000 ft (300m)

I H

C

F

CE Colours

USE

Brown Blue Yellow/Green Red Black White

Live Neutral Ground DMX Data + DMX Data DMX GND

Addr. AL5169

Master-Slave / Automatic / Fixed color Mode
( Only DMX Mode #1 )

Power input

Master

Addr. 001

Addr. 001

AL5169

WARNING ! in this mode, no DMX control device must be present along the line. ATTENZIONE ! in questa modalità non deve essere presente lungo la linea nessun altro dispositivo di controllo DMX.

Parade L – Rev. 6.0

page 8 of 8

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals