Yale YRD256/ YRD456 Assure Lock SL Key Free Touchscreen Deadbolt Installation and Programming Instructions Manual
- June 8, 2024
- Yale
Table of Contents
- Before you begin
- Preparing Door
- Programming Instructions
- Resetting Lock to Factory Default
- Factory Settings
- Definitions
- Feature Programming Through Menu Mode Using Master code*
- Programming Troubleshooting
- Hardware Troubleshooting
- Installing the Z Plus Module
- Installing the ZigBee Module
- Installing the Yale iM1 Network Module
- Connecting the Yale Secure App with the Yale iM1 Network Module
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Yale YRD256/ YRD456 Assure Lock SL Key Free Touchscreen Deadbolt Installation and Programming
Before you begin
DOWNLOAD THE BILT APP
for step-by-step installation instructions & to register your product
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY
Preparing Door
Installing Latch & Strike Plate
Installing Touchscreen Escutcheon
Installing Interior Mounting Plate
Attaching the Cable Assembly
Installing Interior Escutcheon
Testing Operation
Installing Batteries/Handing the Lock
Lock automatically adjusts for proper handing.
Installing Optional Network Module
Installing Cover
Congratulations, you’ve installed the Yale Assure Lock ® ® SL Key Free
Touchscreen Deadbolt ( )! YRD YRD 256/ 456
Continue to Programming Instructions to customize your product.
Programming Instructions
Lock Activation
Master Code must be created before any further programming. PIN
Max User Codes = 250 with Z-Wave Plus or ZigBee network module
Max User Codes = 25 without network module or with iM1 network module
Max User Codes – 12 with Bluetooth
Creating Master PIN Code
Creating User Codes
Master code must be created first. PIN
*Max user codes = 250 with Z-Wave Plus or ZigBee network module
Max user codes = 25 without network module or with iM1 network module
Max user codes = 12 with Bluetooth
Unlocking Door with PIN Code
Code Chart (Duplicate if necessary)
PIN Code Management (With Network Module – Up to 250 Users)
User Type|
User Name
|
User #
|
PIN Code
Master| | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User __| | |
Resetting Lock to Factory Default
When lock is reset to factory defaults all user codes (including the Master code*) are deleted and all PIN programming features are reset to original default settings (see below).
- Remove the battery cover and batteries.
- Remove the interior escutcheon to access the reset button.
- The reset button (see image at right) is located beside the cable connector. PCB
- While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button.
- Replace battery cover.
Upon reset, Master Code creation is the only option PIN available and must be
performed prior to any other programming of the lock.
Factory Settings
Settings
|
Factory Setting
---|---
Master PIN Code
|
Registration *_required_**
Automatic Re-lock
|
Disabled
Inside Indicator Light
|
Disabled (Off)
One Touch Locking
|
Enabled
Privacy Button Setting
|
Disabled
Volume Setting
|
Enabled (Low)
Language Setting
|
English
Lockout Mode
|
Disabled
Automatic Re-lock Time
|
30 Seconds
Wrong Code Entry Limit
|
5 Times
Shutdown Time
|
60 Seconds
*The Master code must be registered prior to any other programming of the lock.
Definitions
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the locked padlock will appear on the RED screen.
Automatic Re-lock Time: After a successful code entry and the unit unlocks, it will automatically re-lock after thirty (30) seconds.
Inside Indicator Light: Located on the interior escutcheon. Shows active status (Locked) of lock and can be enabled or disabled in the (Main Menu selection #3). Advanced Lock Settings Language Setting Mode: Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the lock’s voice prompts
Low Battery: When battery power is low, the Low Battery Warning indicator flashes . If battery power is completely RED lost, use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals below the touchscreen for backup power option. Wake up the lock and enter your pin code to unlock the door.
Master PIN Code: The Master code is used for programming and for feature settings . I t must be created prior to programming the lock. The Master code will also operate (unlock/lock) the lock
Network Module Setting: With the optional Network Module installed, this setting becomes available thru the Main Menu (7) and allows the lock to connect with a network controller.
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock duration or when Automatic Re- lock is disabled). When One-Touch Re-lock is in use any valid code will not (disabled), PIN re-lock the lock.
Previous: While in Menu Mode, pressing this icon cancels the current operation and returns the user to the previous step.
Privacy Mode: Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4 seconds to put the lock in do-not-disturb mode (all pin codes are disabled).
Shutdown Time: The unit will shutdown (flashing ) for sixty (60) seconds and not allow operation after the wrong code RED entry limit (5 attempts) has been met.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User Code: PIN The user code operates the lock. The maximum number of
user codes with Z-Wave Plus or ZigBee network module is 250; without network
module or with iM1 network module, maximum is 25; with Bluetooth, maximum is
12.
Note: When deleting user pin code(s), screen will display user pin code
being deleted.
Volume Setting Mode: The volume setting for code verification is set to Low (2) by default; otherwise it can be set to High (1) Silent (3) for quiet areas.
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid code, the unit will shut down and not PIN allow operation.
Feature Programming Through Menu Mode Using Master code*
-
Touch screen with back of hand or palm to activate.
-
Enter 4-8 digit master code* followed by key.
Lock Response: “Menu mode, enter number, press key to continue.” -
Enter digit corresponding to the function to be performed followed by the key.
Follow the voice commands.
*The Master code must be registered prior to any other programming PIN of
the lock.
Programming Troubleshooting
Symptom | Suggested Action |
---|
Lock does not respond – door is open and accessible.
|
- Touchscreen becomes active when pressed w/whole hand. Use a larger area of the hand or fingers and verify contact with at least 3 area.
- If touchscreen numbers are visible, check to see if they respond when pressed.
- Check batteries are installed and oriented correctly (polarity) in the battery case.
- Check batteries are in good condition; replace batteries* if discharged.
- Check to see if touchscreen harness is fully connected and not pinched.
Lock does not respond – door is locked and inaccessible.|
- Batteries may be completely discharged.
- Apply 9V battery to terminals below the touchscreen for backup power option.
Unit is on for a while then shows no reaction. Lights dim.|
- Batteries do not have enough power. Replace batteries*.
Unit chimes to indicate code acceptance, but the door will not open.|
- Check the door gaps for any foreign objects between door and frame.
- Check that the wire harness is firmly connected to the PCB.
Unit operates to allow access, but will not automatically re-lock.|
- Check to see if Auto Re-lock Mode is enabled.
- Disable Auto Re-lock Mode to lock the door (automatically).
- If low battery indicator is lit (see below), change batteries *.
PIN codes will not register.
|
- PIN codes must consist of 4 to 8 digits to register.
- The same PIN code cannot be used for multiple users.
- Registration/management of PIN codes is set by the authority of the Master Code, which is set first.
- Contact the Master user.
- User codes must be entered within 5 seconds (while touchscreen is active) or process will have to be restarted.
- Check or gear cannot be used as part of the PIN code.
Upon entering a PIN code and pressing key, the unit displays ” invalid code” error or lock times out with- out responding.|
- Lockout Mode is enabled.
- Only the Master can enable/disable Lockout Mode.
- Contact the Master user.
Upon entering a PIN code and pressing the key, the red padlock icon appears and there are different tones.|
- Check to see if the lock is set to Lockout Mode.
- Setting/managing Lockout Mode is done through Master Code only. Contact the Master user.
The unit operates, but it makes no sound.|
- Check to see if Silent Mode is enabled (see Feature #4).
The unit responds ” Low Battery”|
- This is the alert to replace the batteries. Replace all four (4) batteries* with new AA Alkaline batteries.
Upon entering a PIN code and pressing the key, the unit responds ” Wrong number of digits” .|
- The digits entered were incorrect or incomplete. Re-enter the correct code followed by the check key.
* When batteries are replaced, Network Module locks have a real time
clock that will be set through the User Interface (UI ); it is recommended to
verify correct date and time UI particularly those locks operating under
Daylight Saving Time (DST).
** Network Module locks only
Hardware Troubleshooting
Cycle lock in both the locked and unlocked positions. If problems are found:
Door is binding
a. Check that door and frame are properly aligned and door is free
swinging.
b. Check hinges: They should not be loose or have excessive wear on
knuckles.
Bolt will not deadlock
a. Check for sufficient clearance of the bolt within the strike-side
jamb. Correct this by increasing the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing
bolt from properly entering the strike. With the door open, extend and retract
the bolt; if it is smooth, check the strike alignment.
Bolt does not extend or retract smoothly
a. Bolt and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to
bolt.
c. Verify proper door preparation and re-bore holes that are too small or
misaligned.
d. Verify keypad wire harness is routed under the bolt (see Fig. A).
e. Verify bolt is installed with correct side up (Fig. A).
Keypad numerics are scrolling
Remove interior escutcheon and check to ensure that the wire harness lies flat against the back recessed area and is properly routed along the side of the escutcheon and tucked under the plastic cable guide.
NOTE TO INSTALLER AND CONSUMER
While Yale has included several features to prevent lockout ® (9-Volt battery
jumper, low battery warnings), it is still possible for a lockout situation to
occur. Because this product does not have a mechanical override (a key), Yale
recommends to use ® this product in an environment where there are additional
entry points into the dwelling.
FCC:
Class B Equipment
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the Rules. These limits are designed
to provide reasonable protection against harmful interference FCC e in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful Interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ technician for help.
Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user’s authority to operate the equipment.
Industry Canada:
This Class A digital apparatus meets all requirements of the Canadian
Interference Causing Equipment Regulations.
Installing the Z Plus Module
IMPORTANT: the batteries be removed prior must to removing and/or inserting the network module:
- Remove battery cover and batteries.
- Remove and/or insert Network Module.
- Reinstall batteries and battery cover.
Enrolling/Unenrolling the Network Module:
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
To Enroll/Add the Module (Inclusion Mode):
- Enter the 4-8 digit Master code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
To Unenroll/Remove the Module (Exclusion Mode)
- Enter the 4-8 digit Master code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key
Factory Reset – If No Controller:
- See the Lock Installation Manual
- Please use this procedure only when the network primary controller is missing or otherwise inoperable.
For System Integrators: Specific Z-Wave Plus association and parameter information for your lock is available at YaleHome.com/ZwavePlus.
Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user’s authority to operate the equipment.
FCC:
Contain : U4A- 0 FCC ID YRHCPZW FM
Model: 2- YRMZW US
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the Rules. These limits are designed
to provide FCC reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful Interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. -
Consult the dealer or an experienced radio/TV technician for help.
THIS DEVICE COMPLIES WITH PART OF THE FCC RULES 15 . OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND THIS DEVICE MUST ACCEPT
ANY , (2) INTERFERENCE RECEIVED INCLUDING INTERFERENCE , THAT MAY CAUSE
UNDESIRED OPERATION.
Industry Canada:
Contain : 6982A- 0 IC YRHCPZW FM
Model: 2- YRMZW US
Section 7.1.2 of – RSS GEN
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotopically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Section 7.1.3 of – RSS GEN
This Device complies with Industry Canada License-exempt standard(s). RSS
Operation is subject to the following two conditions: 1) this device may not
cause interference, and 2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This radio transmitter 6982A- 0 has been YRHCPZW FM approved by Industry
Canada to operate with the antenna types listed below with the maximum
permissible gain indicated. Antenna types not included in this list, having a
gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Installing the ZigBee Module
IMPORTANT: the batteries be removed prior must to removing and/or inserting the network module:
- Remove battery cover.
- Remove batteries.
- Remove and/or insert network module.
- Reinstall batteries.
- Replace cover.
Enrolling/Unenrolling the Network Module:
This device is a security enabled ZigBee product that is able to use encrypted ZigBee messages to communicate to other security enabled ZigBee products. This device must be used in conjunction with a Security Enabled ZigBee Controller in order to fully utilize all implemented functions. This product can be operated in any ZigBee network with other ZigBee certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
To Enroll/Add the Module (Inclusion Mode):
- Enter the 4-8 digit Master code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
To Unenroll/Remove the Module (Exclusion Mode)
- Enter the 4-8 digit Master code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key
FCC:
Contain : U4A- 0 FCC ID YRHCPZW FM
Model: 2- YRMZW US
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the Rules. These limits are designed
to provide FCC reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful Interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. -
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with radiation exposure FCC limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the rules. FCC Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifications not expressly approved by manufacturer could void the user’s
authority to operate the equipment.
IMPORTANT! Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
Industry Canada:
IC YRHCPZB FM : 6982A- 0
Model: 2 YRMZB
This Device complies with Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions: 1) this device may not
cause interference, and
2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Important Note:
Radiation Exposure Statement:
This equipment complies with radiation exposure limits IC set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
IMPORTANT! Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
Installing the Yale iM1 Network Module
IMPORTANT: the batteries be removed prior must to removing and/or inserting the network module:
- Remove battery cover and batteries.
- Remove and/or insert Network Module.
- Reinstall batteries and battery cover.
Enrolling the iM1 Network Module:
The Yale iM1 Network Module must be used with a Yale Assure Lock or Yale nexTouch Lock and cannot be used in conjunction with any other Yale Network Module.
To Enroll the Module:
- Enter the 4-8 digit Master code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
Connecting the Yale Secure App with the Yale iM1 Network Module
- After following the steps listed on other side of page for enrolling the module, download the Yale Secure app from the App Store . ®
- Ensure Bluetooth is enabled on your iPhone , iPad or iPod touch , and that you’re within a ® ®® ® foot of your Yale lock.
- Open the Yale Secure app and agree to allow the app to access your Home Data.
- If you do not have a home already created, create a new home when prompted. Tap + to add a new Yale Lock.
- The app will search for your Yale Lock. Be sure that you are within close proximity (less than two feet or so). When “Yale Lock” appears, tap to add.
*If the lock does not appear, enter your Master Pin Code on the lock keypad, tap the gear, tap 7, tap gear, tap 1 and then tap gear. - Scan your Accessory Setup Code; shown below, or manually enter within the app.
Accessory Setup Code
Yale Locks & Hardware
Product Support Tel 1-855-213-5841 •
www.yalehome.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group
company
Yale YRD256/ YRD456 Assure Lock SL Key Free Touchscreen Deadbolt Installation
and Programming Instructions Manual – Download
[optimized]
Yale YRD256/ YRD456 Assure Lock SL Key Free Touchscreen Deadbolt Installation
and Programming Instructions Manual – Download
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>