DOMUS SDF100/150 Axial Wall Fans Instructions
- June 7, 2024
- DOMUS
Table of Contents
- DOMUS SDF100/150 Axial Wall Fans Instructions
- OPERATIONS
- Domus Ventilation
- SDF 100/150 Window / Wall Fan
- WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
- FITTING WALL FAN
- WIRING INSTRUCTIONS
- IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DOMUS SDF100/150 Axial Wall Fans Instructions
OPERATIONS
Timer Adjustment – Timer Models only
Isolate the power supply. The timer is factory set at midpoint. Time is set by
placing the black bridge over 2 of the pins on the right hand side of the
timer board. If bridge is not fitted, timer will default to 20 minute setting.
Replace front cover BEFORE switching on the power supply.
HUMIDITY ADJUSTMENT – HUMIDITY MODELS ONLY
Isolate the power supply. Remove the front cover. The humidity control adjustment position is clearly marked. Turn clockwise for less sensitivity and anti-clockwise for greater sensitivity. Turn fully clockwise to turn the humidity sensor off. Replace front cover BEFORE switching on the fan.
SDF 100 RANGE
SDF100B| Standard| SDF100PB| With Pull Cord| SDF100HTBPC|
With Humidistat, Timer
and Pull Cord
---|---|---|---|---|---
SDF100TB| With Timer| SDF100HTB|
With Humidistat
and Timer
| SDF100PIR| With Movement
Detector and Timer
SDF 150 RANGE
SDF150B| Standard| SDF150PB| With Pull Cord| SDF150HTBPC| With
Humidistat,
and Pull Cord
---|---|---|---|---|---
SDF150TB| With
Timer| SDF150HTB| With Humidistat
and Timer| SDF150PBTW| Twin Speed
and Pull Cord
SDF150 HTBTW| Twin Speed with
Humidistat and Pull Cord|
CLEANING
Disconnect power supply before cleaning. It is important to clean fans
regularly as cleaning helps maintain performance and ensure safe, reliable
operation.
The front cover can be removed from the fan and gently washed in warm water,
dry throughly. The interior of the fan can be dusted with a soft brush. Do not
use water.
On humidity control models, please ensure that no water enters the sensor
grille.
230V ac – 50Hz 12W (SDF100) 35W (SDF150)
IPX4 Rating – This product is double insulated.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Domus Ventilation
Cambria House, Caerphilly Business Park, Van Road, Caerphilly
CF83 3ED
Tel: +44 (0)3443 715523 Fax: +44 (0)3443 715524
Email: vent.info@domusventilation.co.uk
www.domusventilation.co.uk
SDF 100/150 Window / Wall Fan
These high quality extractor fans are designed to provide effective ventilation and in order to achieve this, please read these instructions carefully BEFORE installing the fan unit. Failure to comply with these instructions could reduce the life of the product and may invalidate the warranty. This product is suitable for use with up to 1.5 metres of ducting.
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
FITTING WALL FAN
- Select a suitable position for the fan keeping the ducting as short and straight as possible.
- Cut a hole in the wall or ceiling to suit the outside diameter of the ducting.
- Remove the front cover from the fan by undoing the retaining screw at the bottom edge of front cover. Position the fan backplate and mark the retaining screw positions.
- Remove the appropriate cable entry knock out position from the fan backplate and thread power cable through before fixing the fan to the wall or ceiling.
- Ceiling mounted fans must be installed with a condensation trap.
Note: Fans fitted with pull cord switches are not suitable for ceiling mounting.
Note: All the ancillary items can be obtained through Domus stockists.
call +44 (0) 3443 715 523 to find your nearest stockist
WIRING INSTRUCTIONS
It is recommended that the fans be connected into the lighting circuit, with
double pole (3mm) isolation provided before the room light switch and suitably
fused, in accordance with current IEE Regulations.
Window mounted fans should be connected to power supply using a flexible cord
with conductors of between 0.75mm2 and 1.5mm2 only. Wall and ceiling mounted
fans for fixed wiring should be connected to the power supply via a cable with
solid conductors of 1mm2 to 1.5mm2 only.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
MODELS MODELS
MODELS
SDF100TB SDF100B
SDF100PB
SDF100HTB SDF150Bv
SDF150PB
SDF100HTBPC
SDF150HBPC
SDF150TB
SDF150PBTW
SDF150HTB
SDF150HTBTW
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK DO NOT INSTALL IN
SHOWER CUBICLES (ZONES 0 or 1)
MAXIMUM ROOM TEMPERATURE 40ºC
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>