DOMUS Muro Max Series LED Spot Light Instruction Manual
- May 15, 2024
- DOMUS
Table of Contents
DOMUS Muro Max Series LED Spot Light
Specifications
Voltage:| 240V| Lumen (±5%): 3000K
4000K
5000K
| 16W
1700lm 1800lm 1600lm
| 32W
3500lm 3600lm 3300lm
| Dimmable:| No
---|---|---|---|---|---|---
Power:| 16W/32W| Beam Angle:| 100º| Operating Temp:|
-20~+40º C
IP Rating:| IP65| CCT:| 3000K – 4000K -5000K| Power
Frequency::| 60Hz
CRI:| ≥90| Lifespan:| 50,000hrs| Power Consumption:|
0.5W Aprox
Detection Range:| 120º| Detection Distance:| 2-10m
(Adjustable)| Detection Moving Speed:| 0.6-1.5m/s
Rated Load:| Max 300W| | | | |
_ Sensor cover must shield Lux & time settings to retain IP65 rating_
- Sensor cover must shield Lux & time settings to retain IP65 rating
- Muro-Max Series Date: October 18, 2023, 1:42 PM
As the sensor responds to changes in temperature and movement please avoid the following
- Pointing the sensor towards objects with highly reflective surfaces
- Mouting the sensor near heat sources, such as heating vents, air conditioning units
- Pointing the sensor towards objects that may move in the wind
Waterproof Installation Tips
- Fasten the waterproof gasket into the mounting screws
- Feed the cable through the waterproof grommet
- Feed the cable through the cable gland and tighten
- Use water-resistant silicone to seal visible holes
Note
- The lamp must be installed by a professional electrician
- Ensure the power supply is switched off before fitting this product
- Do not touch the lamp when in use
- Keep away from hot steam and corrosive gas
Note
- The lamp must be installed by a professional electrician
- Ensure the power supply is switched off before fitting this product
- Do not touch the lamp when in use
- Keep away from hot steam and corrosive gas
Function
- Time Adjustable: The time adjustment controls how the light will stay after the motion has been detected.
- Turn the time control knob clockwise to increase (up to about 12 minutes) how long the lights stay on or anti-clockwise to decrease (down to about 5 seconds) the time delay.
- Lux adjustment: The Lux adjustment controls sensor mode under different settings. Turn the Lux control knob clockwise to, it is daytime mode, the lamp can induct properly in both daytime and night. Turn the Lux control knob anti-clockwise to ( ), it is night mode, the lamp can induct properly only at night. Please adjust the control knob according to picture 1, if rotate too hard with 360 degrees, the knob will be broken or cannot be adjusted normally.
- Manual mode: When there is no need for an induction setting, start manual mode, and the lamp will operate without the induction function for a long time, once there is an induction demand, the lamp should be operated by hand and start automatic mode.
Manual Mode functions
-
Only the lamp can operate properly can manual mode be started
-
Enter into manual mode; turn Off the lamp twice (OFF-ON-OFF-ON) within 0.5s~2S when the lamp operates properly, the lamp will operate without induction function for 5 hours, and the lamp will change into induction mode
automatically in 1~2 minutes, then it means failed to enter, need to try again. -
Exit manual mode; turn off the lamp twice (OFF-ON-OFF-ON) within 0.5S~2S when the lamp operates properly, then the lamp will be operated with an induction function.
Note
- The lamp must be installed by a professional electrician
- Ensure the power supply is switched off before fitting this product
- Do not touch the lamp when in use
- Keep away from hot steam and corrosive gas.