CLIPSAL Iconic Series PIR Motion Sensor Mechanism Instruction Manual

June 7, 2024
CLIPSAL

CLIPSAL Iconic Series PIR Motion Sensor Mechanism Instruction Manual

CLIPSAL Iconic Series PIR Motion Sensor Mechanism Instruction
Manual

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • It is illegal for persons other than an appropriately licensed electrical contractors or other persons authorised by legislation to work on the fixed wiring of any electrical installation.
  • To comply with all safety standards, the product must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.
  • There are no user serviceable parts inside the product.

Failure to follow these instructions will result in death or serious injury.

DANGER
RISK OF ELECTRIC SHOCK

  • Hazardous voltage and electrical current may be present at the wire leads of this product even when the device is switched off.
  • Lock out and tag the input circuit before accessing the wiring connections.
  • A circuit breaker (250 V a.c. 10 A) Type C must be installed according to AS/NZS 60898.
  • Use a terminal block to connect the PIR Mechanism to the electrical circuit.
  • After wiring, wrap the terminal block with insulating tape.

Failure to follow these instructions will result in death or serious injury.

CAUTION
EQUIPMENT DAMAGE HAZARD

  • Install the device according to instructions in this document.
  • Pay attention to the specifications and wiring diagrams related to the installation.
  • Do not use this product for any other purpose than specified in this instruction.

Failure to follow these instructions can result in minor injuries, or equipment damage.

NOTICE
RISK OF EQUIPMENT DAMAGE OR MALFUNCTION (WIRING CONNECTIONS)

To avoid damaging the equipment and possibly voiding the warranty:

  • Test operation during installation and correct any wiring errors immediately.
  • Keep cable insulation away from the sides of the enclosure to avoid possible damage or long term degradation of the cable insulation.

Failure to follow these instructions can result in equipment damage or malfunction.

Detection pattern and range

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Detection pattern and
range

Sensor locations

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Sensor
locations

Installation example: hallway

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Installation example-
hallway

A. 1× sensor to cover hallway front entrance.
B. 1× sensor to cover hallway back entrance.
C. Zone mask used to prevent detection near the pet door.
D. Sensor covering lounge area. Zone mask used to prevent detection in the hallway zone. (See Zone masking.)

Orientation for multi-gang installation

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Orientation for multi-
gang installation

Fitting the PIR mechanism to the grid

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Fitting the PIR
mechanism to the grid

  1. Open the locking bar (A).
  2. Push the head of the PIR mechanism into the grid aperture until the head clicks into place B.
  3. Close the locking bar (C).

Cabling and connections

Single PIR mechanism

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Single PIR
mechanism

2× PIR mechanisms (e.g. hallway application)

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - 2× PIR
mechanisms

Securing the PIR mechanism fly leads

Note : Ensure that the PIR mechanism fly leads are tied back or otherwise secured in accordance with the wiring rules and regulations that apply in the location where the mechanism is installed.

Mounting the grid

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Mounting the
grid

Adjusting the timer and lux settings

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Adjusting the timer and
lux settings

Zone masking

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Zone
masking

  1. Remove zone mask segments to allow sensor to detect movement A.
  2. Remaining segments prevent detection of movement B.

Fitting the carrier or zone mask to the skin

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Fitting the carrier or
zone mask to the skin

Installing the skin

Removing the skin

Manual override options

Depending on the wiring and the type of switch used, the following manual override options are possible:

Option 1 : Manual override activated by the sensor using a rocker switch.
Option 2 : Manual override bypassing the sensor using a rocker switch.
Option 3 : Manual override with 3-position switch.

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Manual override options
Table

Manual override option 1

Add a 1/2 way switch.

Sensor-activated override

  • Toggle the switch to position B and back to A within 1.5 seconds.
  • Sensor toggles the load state On or Off and maintains that state for the duration of the sensor timer setting.
  • Sensor resumes normal operation once timer expires.

Note : If power to sensor is interrupted for 1.5 seconds, the load is switched on for about 1 minute, then sensor resumes normal operation.

Manual OFF
• Operate switch to position B (turns sensor and load Off).
• Operate switch to position A to resume sensor operation.

Cabling and connections for option 1

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Cabling and connections
for option 1

Manual override option 2

Add a 1/2 way switch. Labelled dolly recommended (“Auto/Manual” shown).

Manual ON
• Operate switch to position B to override sensor and keep load On.
• Operate switch to position A for normal sensor operation.

Cabling and connections for option 2

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Cabling and connections
for option 2

Manual override option 3

Add a 3-position switch. Labelled dolly recommended (“Sensor/Off/On” shown).

Manual OFF
• Operate switch to position B (turns sensor and load Off).
• Operate switch to position A to resume sensor operation.

Manual ON
• Operate switch to position c to override sensor and keep load On.
• Operate switch to position A for normal sensor operation.

Cabling and connections for option 3

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Cabling and connections
for option 3

Technical specifications

CLIPSAL Iconic Series PIR Motion Sensor Mechanism - Technical
specifications

Customer care

Warranty information
We warrant this product for 2 years. For details, please visit http://www .schneider-electric.com.au/en/about-us/legal/terms-and-conditions.jsp.

Our goods also come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Schneider Electric (Australia) Pty Ltd
Customer Care Australia: 1300 369 233
Email: customercare.au@schneider-electric.com
www.schneider-electric.com.au

Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

© Schneider Electric 2017

This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric.

F2842

October 2017

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals