HD-75DE AMI Deluxe Mineral ROTM Water Purifier Instructions
- June 13, 2024
- AMi
Table of Contents
- HD-75DE AMI Deluxe Mineral ROTM Water Purifier
- Product Information
- Product Usage Instructions
- AMI TECHNOLOGY – A Breakthrough in Water Purification*
- Features of AMI Deluxe Mineral ROTM
- Items in the Box
- Important Instructions
- Reverse Osmosis Process
- Automatic Operation
- Water Flow Diagram
- Installation Instructions
- TDS Adjustment
- Maintenance
- Important Safety Instructions
- Technical Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HD-75DE AMI Deluxe Mineral ROTM Water Purifier
Product Information
AMIDELUXE
The AMIDELUXE is a state-of-the-art water purifier designed and
manufactured by Applied Membranes, Inc. It is a Deluxe Mineral ROTM Water
Purifier that utilizes multiple purification technologies, including Reverse
Osmosis (RO) and Hollow Fibre Ultrafiltration (UF) membrane, to effectively
filter out bacteria, viruses, cysts, and other impurities from your water. The
cleaner features an adjustable TDS Control System for easy TDS adjustment in
purified water. It also offers fully automatic operation with an auto-on and
auto-off function for convenience. The tamper-proof RO/UF membranes are fused
inside the membrane housing, ensuring their durability and reliability. The
purifier is suitable for purifying Brackish Water, Tap Water, and Municipal
Water Supply. It comes with an optional 3.2-gallon storage tank that provides
purified water on demand. The use of push-fit fittings ensures leak-free
performance and maintenance-free operation.
Product Usage Instructions
- Avoid exposure to direct sunlight: Install the AMIDELUXE in a location away from direct sunlight and damp areas to prevent damage.
- Connect the reject water drain: Ensure that the reject water connection to the drain saddle assembly is fully inserted and not leaking.
- Check water temperature: Make sure the temperature of the water entering the purifier is within the range of 10-40°C.
- Consider water source distance: The maximum distance between the water source and the purifier should not exceed 3 meters.
- Avoid sharp bends in pipe fittings: Prevent sharp bends in the pipe fittings and avoid bending or blocking the rejected water pipe.
- Ensure proper ventilation: Do not confine the purifier in a cabinet; provide adequate ventilation for optimal performance.
- Long periods of non-use: If the purifier will not be used for more than two days, switch off the power supply and drain the storage tank.
- Regularly drain the storage tank: To keep the storage tank clean, drain it once every 30 days.
- Use Genuine AMI spares: For optimum performance and longevity, always use genuine AMI spares for replacements.
For detailed installation instructions, maintenance guidelines, important
safety instructions, technical specifications, and more, please refer to the
Instruction Handbook provided with your AMIDELUXE water purifier.
For any further assistance or inquiries, don’t hesitate to get in touch with
AppliedMembranes, Inc. at 760-734-8734
or visit their website at
www.appliedmembranes.com.
Dear Customer,
To begin with, allow us to thank you for your trust in water purification. We
take pride in our reputation for product quality and industry-proven
performance. We are
certain that your decision to own an AMI Deluxe Mineral TM RO water purifiers
will go a long way toward keeping you and your family in good health. We are
confident that you will be satisfied with its performance and that it will
serve your need for safe and clean drinking water without any compromise. This
guide will help you in getting the best out of your water purifier. Please go
through this booklet to familiarize yourself with its operation and
maintenance.
Best Wishes
Applied Membranes, Inc.
AMI TECHNOLOGY – A Breakthrough in Water Purification*
Presenting the Mineral RO Water Purifier based on state-of-the-art technology, for purer TM AMI Deluxe and healthier water. At the heart of the Mineral RO water purifier is a Reverse Osmosis membrane having a TM AMI Deluxe pore size as small as 0.0001 microns that reduce even dissolved impurities (salts and heavy metals) as well as harmful micro-organisms (bacteria, viruses etc.) and even converts hard water to sweet and purer drinking water. It also incorporates a UF process to give double protection from harmful microorganisms. Mineral RO also allows the user to control the Total Dissolved Solids (TDS) TM AMI Deluxe level of purified water.
Features of AMI Deluxe Mineral ROTM
-
Multiple Purification by RO and Hollow Fibre UF Membrane effectively filters out bacteria, viruses, and cysts.
-
Adjustable TDS Control System facilitates TDS adjustment in purified water.
-
Fully automatic operation with auto-on and auto-off function.
Tamper-proof RO/UF Membranes fused inside membrane housing. -
Suitable for purification of Brackish / Tap Water / Municipal Water Supply.
-
3.2 gallons optional storage tank that makes purified water available on demand.
-
Fully automatic operation, with auto-on and auto-off function.
-
Use of push-fit fittings to prevent leakage and maintenance-free performance.
Items in the Box
- TM AMI Deluxe Mineral RO Water Purifier: 1 Qty.
- 3-Way Connector: 1 Qty.
- S.S. Ball Valve: 1 Qty.
- Food Grade Pipe ¼ inch (Blue): 98.4 inches
- Food Grade Pipe ¼ inch (White): 196.8 inches
- Instruction Manual: 1 Qty.
- Screws & Plastic Inserts: 2 Qty. each
- Hydrostatic Storage Tank 3.2G: Optional
- Sticker Center Drill: 1 Qty.
Important Instructions
Reverse Osmosis Process
The Reverse Osmosis process, also known as hyperfiltration, is the finest filtration process known to date. The process ensures the reduction of particles as small as ions from a solution. Reverse Osmosis uses a semi- permeable membrane to reduce salts from potable/brackish water. In Reverse Osmosis, water pressure applied to the concentrated side forces the process of osmosis into reverse. Under enough pressure, treated water is “squeezed” through the membrane from the concentrated side to the diluted side. Salts dissolved in water as charged ions are repelled by the RO membrane. The rejected impurities on the concentrated side of the membrane are washed away in a stream of wastewater and thus do not get accumulate as in a traditional filter.
UF Process
AMI Ultra-Filtration is a separation process that uses a UF membrane with a
pore size of 0.1–0.01 microns. This UF membrane has the capacity to remove
colloidal materials including bacteria, cyst and even viruses from drinking
water. Low applied pressure is therefore sufficient to achieve high flux rates
from an Ultra Filtration membrane.
Automatic Operation
- The purifier automatically shuts off when the storage tank is full.
- The purifier does not start when inlet water supply 2 pressure falls below 4.267 (psi/cm ).
- The purifier automatically restarts when the water level drops below the maximum.
- The purifier does not allow any water rejection in the absence of electricity or when the tank is full.
Water Flow Diagram
Electrical Circuit Diagram
Installation Instructions
The AMI Deluxe Mineral RO Water Purifier is a product of advanced technology
that ensures safe and clean drinking water. The purifier is easy and
convenient to install.
Recommended Site Preparations:
- Single Phase 100-250 V AC, 50-60 Hz connection not more than 118.1 inches away from the point of installation of purifier.
- Raw water supply with ½ inch nipple not more than 118.1 inches away.
- Drain for rejected water not more than 118.1 inches away.
- Space as per dimensions of the purifier.
- Wall/plain surface for mounting two screws and holding the machine.
- The system and installation needs to comply with state and local laws and regulations.
Specific Instructions:
- AMI Deluxe Mineral RO is an under-the-sink purifier. Make sure that it is only mounted on a wall. Avoid installation on wooden and metallic stands.
- For optimum performance and minimum inlet pressure required, ensure that the raw water supply tank is at least 10 ft above the level at which the purifier is installed.
- It is preferable to install the purifier near a sink so that the faucet can be mounted on the sink and the inlet and reject water lines are easily available.
Installation Instructions:
- Screw in the two 10×50 self-tapping screws on a same horizontal level at a distance of 7.32 inches from each other in the wall. This can be preferably done under the kitchen sink.
- Carefully hang the purifier on the wall with the help of wall mounting slot holes present on the back side of the purifier as shown in Figure 1.
- Fix the SS ball valve to the inch port of the 3-way connector.
- Connect the 3-way connector to the raw water supply as shown in Figure 2. The threaded end of the 3-way connector is fitted in line with the raw water supply. The other end can be connected to a tap or can be plugged off if not required.
- Now connect one end of the white pipe to the SS ball valve and the other end to the inlet of the rightmost sediment filter (labeled as No.1 in the system flow diagram) (Note: White pipe is for raw water supply).
- Drill a 1/4” hole in the drain pipe, below the sink. Install the Drain Clamp by first applying the foam gasket inside the front half of the drain saddle. Punch out the cut-out hole in the center of the pad, remove the adhesive backing, and adhere to the inside of the drain saddle, ensuring the holes are aligned. Align the hole drilled in the drain pipe with the hole in the drain saddle. Use a Phillips screwdriver to tighten the clamp. Avoid over-tightening.
- Connect one end of the blue pipe to the outlet of the flow restrictor tube (labeled as No. 11 in the system flow diagram) and insert tubing from the
- Reject the Water line to the quick connect fitting on the drain line and check the seal (Note: Blue pipe is for reject water).
- Make a drill of 0.43 inches on the top of the sink or kitchen bed where the faucet (labeled as No. 16 in the system flow chart) can be installed conveniently as per the drawing. Secure the faucet to the sink, by tightening the brass nut washer.
- Tighten the 90-degree ball valve to the tank and connect it to the outlet of the purifier as shown in the drawing.
TDS Adjustment
The unique TDS Controller enables customers to retain the contents of natural minerals in purified water as per their requirements.
- Turning the screw of the valve anti-clockwise results in increased mineral content.
- Turning the screw of the valve clockwise results in decreased mineral content.
Starting-up the Purifier
- Switch on the power supply.
- Wait approximately for half an hour so that the storage tank fully fills up**.
- Switch off the power supply.
- Drain off the storage tank by opening the faucet to remove any dust particles from the pipe and storage tank.
- Close the faucet & switch on the power supply
- The purifier is ready to use.
Recommended Usage of Rejected Water
Although the rejected water has a high concentration of salts, it is
absolutely clean and free of impurities like chlorine, dirt, sand, etc. which
are present in raw water. This rejected water usually goes down the drain but
if required, can be used for gardening purposes. It has a high concentration
of salts and minerals which accelerates plant growth. Rejected water can also
be used for cleaning purposes, i.e. cleaning utensils, mopping, etc.
Maintenance
To ensure that the purifier operates at its optimum level, routine maintenance must be performed. The frequency of the maintenance will greatly depend upon the raw water quality and consumption of purified water.
- Replace sediment, activated carbon block and micronic filter after every 12 months. It is recommended to change the Flow Restrictor when the filters are replaced.
- Replace the RO membrane once in a year.
- If you are not going to use the purifier for a long time (in case you are on a holiday, tour or out of home), make sure that you disconnect the power supply, turn off the raw water supply and drain the storage tank.
Note : The reverse osmosis system contains a replaceable treatment
component critical for the effective reduction of total dissolved solids and
that product water shall be tested periodically to verify that the system is
performing properly.
Replacement of spare parts are as under:
- H-F0833-43QC Inline Sediment Filter 8”
- H-F0832-43QC Inline Carbon Filter 8”
- M-T1808-ENK RO Membrane Welded 8” Housing
- M-U1808-ENK UF Membrane Housing 8”
- H-RQC018 Flow Restrictor FRT 550/600
- H-F0834-43ST Carbon Polishing Filter
“This reverse osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer, to ensure the same efficiency and contaminant reduction performance.”
Important Safety Instructions
- If the supply cord is damaged, it must be replaced by the original part in order to avoid hazard
- Children should be supervised to ensure that they do not play with the appliance
Technical Specifications
Product | AMI Deluxe |
---|
Product Code Product Generic Name Product Colour Application
Purification Production Rate Body Material
Mounting
Product Dimensions (inches) Inlet Water Pressure/Temp. (Min)
| HD-75DE
Water Purifier White
Suitable for Purification of Brackish, Tap Water, Municipal Corporation Water.
3.96 (gal/hr.) ABS Food Grade Plastic
Under-the-Counter 16.14 (L) X 8.85 (W) X 11.22 (H)
4.267 (psi/10oC)
Inlet Water Pressure/Temp. (Max) Filter Cartridge
Net Weight
Storage Capacity
| 56.893 (psi/40oC) Sediment, Activated Carbon, UF and Post Carbon.
13.7 (lbs)
3.2 (gallons)
Maximum Duty Cycle
Membrane Type Booster Pump Voltage
| 19.8 (gal/day.) Thin Film Composite RO
24 V DC
Total Power Consumption Input Power Supply
IPX Numbur
| 60 (W)
Single Phase 100-250 V AC, 50-60 Hz.
IPX1
- Treatment capacity tested for tap water having TDS level of 750 ppm at room temperature.
References