tp-link 5-Port 10 100Mbps Desktop PoE PoE Switch Installation Guide

June 7, 2024
tp-link

tp link

Installation Guide
5-Port 10/100Mbps Desktop PoE/PoE+ Switch

LED Explanation

Power
On: Power on
Off: Power off

Power

PoE MAX
PoE Max

TL-SF1005LP
On: 34 W≤Total power supply < 41 W
Flashing: Total power supply ≥ 41 W
Off: Total power supply < 34 W

Link/Act and PoE Status

tp-link 5-Port 10 100Mbps Desktop PoE PoE Switch - PoE
Status

TL-SF1005P
On: 60 W≤Total power supply < 67 W
Flashing: Total power supply ≥ 67 W
Off: Total power supply < 60 W

Switch Explanation

Priority (Port 1–2)

Off: All the ports transmit data in the same priority.
On: Port 1 and 2 transmit data in a higher priority than other ports. When congestion occurs, packets that are transmitted by the ports with higher priority occupy the whole bandwidth.
Note : For simplicity, we will take TL-SF1005P for example throughout the Guide.

Extend (Port 1–4)

Off: Port 1–4 run at 10/100 Mbps and support PoE power supply up to 100 m away.
On: Port 1–4 run at 10 Mbps and support PoE power supply up to 250 m away.

Connection

Note : 1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. TL-SF1005LP can supply up to 15.4 W for each PoE port and 41 W for all PoE ports.
3. TL-SF1005P can supply up to 30 W for each PoE port and 67 W for all PoE ports.

Frequently Asked Questions (FAQ)

Q1. Why is the Power LED not lit?
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, please try the following:
A1: Make sure the AC power cord is connected to the switch with power source properly.
A2: Make sure the voltage of the power supply meets the requirements of the input voltage of the switch.
A3: Make sure the power source is ON.
Q2. Why is the Link/Act LED not lit while a device is connected to the corresponding port?
Please try the following:
A1: Make sure that the cable connectors are firmly plugged into the switch and the device.
A2: Make sure the connected device is turned on and works normally.
A3: The cable must be less than 100 meters long (328 feet).
Q3. Why are PoE ports not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the maximum, the PoE port with a smaller port number has higher priority. The system will cut off  power to the ports with larger port numbers to ensure supplying to other ports.
Take TL-SF1005P as an example. If port 1, 2 and 4 are consuming 15.4 W respectively, and an additional PoE device with 21 W is inserted to port 3, the system will cut off the power of port 4 to compensate for the overload.

To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community.
For technical support and other information, please visit https://www.tp- link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome to email techwriter@tp-link.com.cn.

http://www.tp-link.com/support

PoE Disclaimer

The speed of the ports in extend mode will downgrade to 10 Mbps. The actual transmission distance may vary due to power consumption of PoE-powered devices or the cable quality and type.
PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.

EU Declaration of Conformity

TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp- link.com/en/ce.

Specifications

General Specifications

Standard| IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3af, IEEE802.1p IEEE 802.3at (Only for TL-SF1005P)
---|---
Protocol| CSMA/CD
Interface| 5 10/100 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX PoE Ports: Port 1-Port 4 Total Power Supply: 41 W (for TL-SF1005LP)/67 W (for TL-SF1005P)
Network Media (Cable)| 10BASE-T: UTP category 3, 4, 5 cable (maximum 100 m); EIA/TIA-568  100Ω STP (maximum 100 m) 100BASE-TX: UTP category 5, 5e cable (maximum 100 m); EIA/TIA-568 100Ω STP (maximum 100 m)
Switching Capacity| 1 Gbps
MAC Address Table| 2K
Transfer Method| Store-and-Forward
MAC Address Learning| Automatically learning, automatically aging
Power Supply| External Power Adapter Input: 100-240 VAC, 50/60 Hz  Output: 53.5 VDC  /0.81 A (for TL-SF1005LP) 53.5 VDC /1.31 A (for TL-SF1005P)
Wall Mountable| Ye s
Distance Between Mounting Holes| 39 mm

Environmental and Physical Specifications
Operating Temperature 0˚C to 40˚C (32˚F to 104˚F)
Storage Temperature -40˚C to 70˚C (-40˚F to 158˚F)
Operating Humidity 10% to 90%RH non-condensing
Storage Humidity 5% to 90%RH non-condensing

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device.
  • Do not use damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • Adapter shall be installed near the equipment and shall be easily accessible.
  • Place the device with its bottom surface downward.
  • Use only power supplies which are provided by the manufacturer and in the origin packing of this product. If you have any questions, please don’t hesitate to contact us.

FCC compliance information statement

Product Name: Gigabit Desktop Switch
Model Number: TL-SG1005LP/TL-SG1005P

Component Name

|

Model

---|---
I.T.E. POWER SUPPLY| T535081-2-DT (For TL-SF1005LP)
T535131-2-DT (For TL-SF1005P)

Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.• Reorient or relocate the receiving antenna.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated. Issue Date: 2020.2.24

CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

FCC compliance information statement
Product Name: I.T.E. POWER SUPPLY
Model Number: T535081-2-DT/T535131-2-DT
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.
    Issue Date: 2020.2.24
    Mounting Requirements
    To mount the device on a wall, use 2 screws that comply with ANSI B1.1 4#, (5#), 6#, 8# standard and are more than 8.5 mm in length. When the screws are fixed on the wall, the distance between the screw head and the wall should be more than 1.5 mm.

Standard

|

Diameter

---|---
ANSI B1.1 #4| 2.845 mm
ANSI B1.1 #5| 3.175 mm
ANSI B1.1 #6| 3.505 mm
ANSI B1.1 #8| 4.166 mm

Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Explanation of the symbols on the product label

| DC voltage
---|---
Indoor-Icon-png| Indoor use only
icon| RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment  (WEEE). This means that this product must be handled pursuant to European directive  2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.