Thank you for purchasing this Marble glass semi flush. Please read the instructions carefully before use to ensure safe and satisfactory operations of this product. Please keep this instruction for future reference.
Warnings!
-
For your safety, this product must be installed in accordance with local Building Regulations.
-
If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or phone your Local Authority.
-
To prevent electric shock, switch off the mains supply before installing or
maintaining this product. Ensure other persons cannot restore the electricity supply without your knowledge. -
Always use the correct bulb type with the correct wattage as indicated in the specification table. This product is Class I = and should be fitted to a lighting Supply (with earth) protected by a 5 amp fuse or equivalent circuit breaker.
-
When changing the bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully.
Caution! The bulb and surrounding parts can become hot during use.
This fitting is rated IP44 making it suitable for use in Zones 1 & 2 of a
bathroom when fitted in accordance with IEE wiring regulations (see diagram
overleaf). Fitting must be connected to a supply protected by a 30mA RCD in
Zone 1.
This symbol indicates that this product should not be treated For indoor use
only.
Care instructions
We recommend cleaning with a soft dry cloth. Do not use abrasive materials as
these will damage the finish.
Replace bulb from John Lewis or established brand of the same type and
compatibility.
Parts list
Assembly
Never install your appliance on a wet, freshly painted or plastered surface.
Ensure the house electricity supply is switched off at the fuse box. If
removing an existing fitting, note down all wiring connections. Check the
fixings will not touch any existing wiring before drilling and attaching the
light to the ceiling.
Ensure you thread the ceiling wires through the black insulating tube fixed to
the appliance.
Step 1
Remove mounting plate (B) from fitting by removing the retaining screws
and any washers, retain for later. Using the mounting plate as a template,
mark and then drill the fixing holes in the ceiling (ensure the screws are
firmly fixed into a solid or other suitable mounting and not just the
plasterboard.) Take care not to damage wiring. Attach mounting plate to the
mounting surface using suitable fixings. Do not attach fitting to mounting
plate at this stage. Make sure no wires are trapped in the process.
Step 2
Ensuring that the power has been isolated, Lever open the terminal block box
cover with a screwdriver, pierce a hole in the black rubber end cap of the
terminal block then feed supply cable through.
Make electrical connections as follows:
• Connect supply live to fitting live (marked “L”) on the terminal block.
• Connect supply neutral to fitting neutral (marked “N”) on the terminal block
• Connect the supply earth to the earth (marked “ ”) on the terminal block.
NOTE: Ensure electrical connections are tight and no loose strands of wire are left out of the connector block. Ensure terminals and rubber sleeve are correctly seated then close connector block housing. Excess cable must be carefully located inside ceiling cup or within the ceiling void.
Excess cable must be carefully located inside ceiling cup or within the ceiling void. Carefully offer fitting over mounting bracket then secure in place with the screws and washers removed earlier.
Step 3
Carefully remove the protective packaging surrounding the glass shades.
Fit the bulb, type and wattage as indicated on the fitting (bulb not
supplied). The wattage indicated must not be exceeded.
Place the silicone washer over the lamp holder.
To fit the shade: Offer the glass shade over the lamp holder section,
align the treads and carefully screw into place. If cross-threading occurs,
undo and start again. Take care not to overtighten as this may cause damage to
the the glass or the fitting. Once installation is complete, the electricity
may be restored at the fuse box
Recommended bulb
3 x 5 Watt G9 energy efficient LED
Bulb not included
Specification
- Max power: 5W
- Voltage: 220~240V, 50/60Hz
- IP44
- Weight 1.4 Kg
Please retain these instructions for future reference.
as normal house-hold waste and it should be recycled. John Lewis does not
operate in store take back, but as members of the Distributer Take Back scheme
have funded the development and upgrade of recycling facilities across the UK.
Please take it to your nearest collection facility or for further details
contact your local council or visit www.recycle-more.co.uk.
We have taken great care to ensure that this product reaches you in perfect
condition. However, should any parts be damaged or missing please e-mail
lightingparts@JLPspares.co.uk
Troubleshooting
Why is the light not working when switched on?
Check your power supply is switched on
Turn off light and check that the bulb is inserted correctly
Check the bulb is still in working order.