Thank you for purchasing this Malik chandelier.
Please read the instructions carefully before use to ensure safe and
satisfactory operations of this product. Please keep this instruction for
future reference.
Warnings!
For your safety, this product must be installed in accordance with local
Building Regulations.
If in any doubt, or where required by the law, consult a competent person who
is registered with an electrical self-certification scheme. Further
information is available online or phones your Local Authority.
To prevent electric shock, switch off the mains supply before installing or
maintaining this product. Ensure other persons cannot restore the electricity
supply without your knowledge.
Always use the correct bulb type with the correct wattage as indicated in the
specification table.
This product is Class I = and should be fitted to a lighting Supply (with
earth) protected by a 5 amp fuse or equivalent circuit breaker.
When changing the bulb, always switch off at the mains and allow the old bulb
to cool down before handling. Dispose of used bulbs carefully.
Caution! The bulb and surrounding parts can become hot during use.
For indoor use only.
Care instructions
We recommend cleaning with a soft dry cloth. Do not use abrasive materials as
these will damage the finish.
Replace bulbs from John Lewis or established brands of the same type and
compatibility.
Parts list
Assembly
Never install your appliance on a wet, freshly painted, or plastered surface.
Ensure the house electricity supply is switched off at the fuse box. If
removing an existing fitting, note down all wiring connections. Check the
fixings will not touch any existing wiring before drilling and attaching the
light to the ceiling.
Ensure you thread the wall wires through the black insulating tube fixed to
the appliance.
Step 1
Remove mounting bracket from the fitting by removing the retaining screws and
any washers, retain for later. Using the mounting bracket as a template, mark
and then drill the fixing holes in the ceiling (ensure the screws are firmly
fixed into a solid or other suitable mounting and not just the plasterboard.).
Take care not to damage wiring. Attach the mounting bracket to the mounting
surface using suitable fixings. Do not attach the fitting to the mounting
bracket at this stage. Make sure no wires are trapped in the process.
Step 2
Rotate the main stem onto the receiving collar on the central lamp holder
section of the fitting. If cross-threading occurs undo and start again. Take
care not to overtighten as this may cause damage to the fitting.
Height Adjustment: This fitting is height adjustable at the point of
installation only. No attempt must be made to adjust the height once it has
been attached to the ceiling. If adjustment is required at a later date the
fitting must be isolated from the mains and removed from the ceiling first.
Using two pairs of pliers carefully open the chain links and remove the
required number of links.
Close the links.
Note: Cloth should be used between the jaws of the pliers to protect the
decorative finish. Pull any excess cable through the ceiling cup.
Note: The chain and not the electrical cable must support the weight of the
fitting.
Step 3
Ensuring that the power has been isolated, connect the electrical supply wires
to the connector blocks corresponding terminals.
Wrap the terminal block in two layers of insulating tape.
Make the electrical connections as follows:
- Connect the supply live (normally brown or red) to fitting life (embossed “L”) on the terminal block housing.
- Connect the supply neutral (normally blue or black) to fitting neutral (embossed “N”) on the terminal block housing.
- Connect the supply earth (normally green/yellow or unsheathed) to earth (embossed “ ”) on terminal block housing.
NOTE: Ensure electrical connections are tight and no loose strands of
wire are left out of the connector block. Ensure terminals and rubber sleeves
are correctly seated then close connector block housing.
The excess cable must be carefully located inside the ceiling cup or within
the ceiling void. Carefully offer fitting over mounting bracket then secure in
place with the screws and washers removed earlier.
Fit the bulb , type, and wattage as indicated on the fitting (bulb not
supplied). The wattage indicated must not be exceeded.
Once installation is complete, the house electricity may be restored at the
fuse box.
Recommended bulb
5 x 6-9 Watt E14 (SES) energy-efficient LED candle bulb.
or
5 x 42 Watt E14 eco halogen candle bulb.
Bulb not included
Specification
Max power: 42W
Voltage: 220~240V, 50/60Hz
IP20
Weight 1.7Kg
Please retain these instructions for future reference.
This symbol indicates that this product should not be treated as normal household waste and it should be recycled. John Lewis does not operate in- store take back, but members of the Distributor Take Back scheme have funded the development and upgrade of recycling facilities across the UK. Please take it to your nearest collection facility or for further details contact your local council or visit www.recycle-more.co.uk We have taken great care to ensure that this product reaches you in perfect condition. However, should any parts be damaged or missing please e-mail lightingparts@JLPspares.co.uk
Troubleshooting:
Why is the light not working when switched on?
Check your power supply is switched on Turn off the light and check that the
bulb is inserted correctly Check the bulb is still in working order.