PHILIPS coffee maker Fully-auto Pod coffee machine Instructions

June 7, 2024
Philips

PHILIPS coffee maker Fully-auto Pod Cover

PHILIPS coffee maker Fully-auto Pod Overview 1PHILIPS coffee maker Fully-auto Pod Overview
2PHILIPS coffee maker Fully-auto Pod Overview
3PHILIPS coffee maker Fully-auto Pod Overview
4PHILIPS coffee maker Fully-auto Pod Overview
5PHILIPS coffee maker Fully-auto Pod Overview
6PHILIPS coffee maker Fully-auto Pod Overview
7PHILIPS coffee maker Fully-auto Pod Overview
8
Introduction

Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome. This new SENSEO® machine (HD6554, HD6555, HD6556) offers you more choice with Intensity Select. Next to the long, smooth SENSEO® coffee you can also brew a strong, smaller SENSEO® coffee by simply pressing the button twice.

Clean cold water
Use clean cold water every day. If you have not used the machine for 1 day, you have to flush it with clean cold water before you use it again. To flush the machine, fill the water reservoir with clean cold water, place a bowl or 2 cups under the spout and press the 2-cup button a few times to brew hot water until the water reservoir is empty.

Fresh coffee pods
Use the SENSEO® coffee pods that have been specially developed for your SENSEO® coffee machine for a full, round taste. SENSEO® coffee pods stay fresh longer when you store them in a storage container.

A clean machine
Clean and descale the Philips SENSEO® coffee machine every 3 months. For more information on why it is important to descale, how to descale or which descaler to use, visit our website at www.philips.com/descale- senseo.

Important safety information
Read this user manual carefully before you use the machine and save it for future reference.
Danger – Never immerse the machine in water or any other liquid.

Warning
– Check if the voltage indicated on the bottom of the machine corresponds to the local mains voltage before you connect the machine.
– Always put the plug in an earthed wall socket.
– Do not use the machine if the plug, the mains cord or the machine itself is damaged.
– Always unplug the machine before you clean it.
– If the mains cord is damaged, you must have it replaced by Philips, a service center authorized by Philips or similarly qualified persons in order to avoid a hazard.
– This machine can be used by children aged from 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the machine in a safe way and if they understand the hazards involved.
– Cleaning and user maintenance shall not be made by children unless they are older than 8 and supervised.
– Keep the machine, its accessories and its cord out of the reach of children aged less than 8 years.
– Children shall not play with the machine.

Caution
– Always return the machine to a service center authorized by Philips for examination or repair. Do not attempt to repair the machine yourself, otherwise your warranty becomes invalid.
– After unpacking the machine, never put the machine on its side. Always keep it in upright position, also during transport.
– Never put normal ground coffee or use torn pods in the pod holder, as this causes it to become blocked.
– Do not use the machine in combination with a transformer, as this could cause hazardous situations.
– Do not use the machine in combination with water softeners based on sodium exchange.
– Always put the machine on a flat and stable surface.
– Do not place the machine on a hotplate or directly next to a hot oven, heater or similar source of heat.
– Do not place the machine in a cabinet when in use.
– Never let the machine operate unattended.
– Do not use the machine at altitudes higher than 2200 meters above sea level.
– Do not use or store the machine at a temperature below 0 °C. Water left in the machine may freeze and cause damage.
– Never flush the machine or let it brew coffee when the spout is not in place.
– Never pour any other liquid than clean cold water into the water reservoir.
– Flush the machine with fresh water before you use it for the first time. This causes the system to fill with water, which is essential for the machine to work properly.
– Descale the machine at least every 3 months. If you do not descale the machine regularly, it may stop working properly. In this case, repair is not covered by your warranty.
– Never interrupt the descaling process.
– Never use a descaling agent based on mineral acids such as sulphuric acid, hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar). These descaling agents may damage your coffee machine.
– The machine is intended for normal household use only. It is not intended for use in environments such as staff kitchens of shops, offices, farms or other work environments, nor is it intended to be used by clients in hotels, motels, bed and breakfasts and other residential environments.

Compliance with standards
This Philips machine complies with all applicable standards and regulations regarding exposure to electromagnetic fields. The energy consumption of this machine in off mode is less than 0.5 Watt. This means that this machine complies with European Directive 2009/125/EC, which sets the ecological design requirements for energy-using products.

Frost-free storage
If the coffee machine has already been used and therefore has been flushed with water, it may only be used and stored in a frost-free place to prevent it from becoming damaged.

Ordering accessories
To buy accessories or spare parts, visit www.philips.com/parts-and- accessories or go to your Philips dealer. You can also contact the Philips Consumer Care Center in your country (see the international warranty leaflet for contact details).

Warranty and support
If you need information or support, please visit www.philips.com/support or read the international warranty leaflet.

Recycling
– This symbol means that this product shall not be disposed of with normal household waste (2012/19/EU).
– Follow your country`s rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.

Troubleshooting

This chapter summarizes the most common problems you could encounter with the machine. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions or contact the Consumer Care Center in your country.

Problem Possible cause Solution
My coffee cup overflows with cold coffee You did not flush the machine before
first use. Always flush the machine before first use.
The indicator light flashes slowly. The machine is heating up. If this takes

longer than 2 minutes, contact the Philips Consumer Care Center in your country
The indicator light flashes quickly.| There is not enough water in the water reservoir| Fill the water reservoir and make sure you place the water reservoir properly into the machine.
| The float in the water reservoir may be stuck.| Empty the water reservoir and shake it a few times to release the float. Clean the water reservoir with hot water and some washingup liquid or in the dishwasher.
The coffee is not hot enough.| You need to descale the machine.| Descale the machine according to the instructions.
The coffee temperature in the cup decreases quickly.| Do not use cups that are too large.| Use thin-walled cups. Thin-walled cups absorb less heat from the coffee than thick-walled cups.
| | You can preheat the coffee machine and cup by brewing a cup of hot water first without placing a coffee pod in the pod holder.
Intensity select: after pressing the coffee button twice, I do not get a stronger coffee.| You have pressed the coffee button twice too fast or you have waited longer than 3 seconds after pressing the button for the first time.| Pressing the coffee button twice to get a stronger coffee is possible within a time frame of 3 seconds. The LED light on the machine will shine less bright if the programming was successful.
I cannot open the lid.| A temporary vacuum has developed under the lid.| Switch off the coffee machine. Pull up the lever and wait 24 hours before you open the lid. You may need to use some force. Always make sure the pod holders are clean and the sieve is not clogged to prevent a vacuum.
The coffee machine produces less coffee than before.| Perhaps the sieve in the center of the pod holder is clogged.| If the sieve is clogged, use a washing- up brush to unclog the sieve. If you cannot unclog it properly with the washing-up brush, put the pod holder in the machine and descale the machine according to the instructions.
| Perhaps you have pressed the 1 or 2-cup button twice.| This machine has Intensity Select. If you press the button twice, you get a smaller cup of stronger coffee.
I cannot close the lid properly.| Perhaps a used coffee pod is sticking to the water distribution disk.| If this is the case, remove the used pod.
The coffee is not strong enough.| You may not have used the right number of pods or may have pressed the wrong button.| Use 1 pod in combination with the 1-cup pod holder and the 1-cup button. Use 2 pods in combination with the 2-cup pod holder and the 2-cup button.
| The pod(s) may not have been placed in the pod  older properly.| Place the coffee pod(s) properly in the center of the pod holder, to prevent water from escaping along the edge of the pod(s). When you use two coffee pods on top of each other, make sure that the convex sides of both pods point downwards and press the pods lightly into the pod holder. Make sure that the coffee in the pod is distributed evenly.
| You may have used the same pod twice.| Place a new pod in the pod holder to brew a fresh cup of coffee.
| Perhaps you need a different flavor.| If you prefer a more robust flavor, SENSEO® coffee pods with a stronger blend are available.
| HD6554, HD6555, HD6556: Use intensity select.| Press the button twice to brew one or two small cups of stronger coffee.
The coffee is too strong.| Perhaps you need a different flavor.| If you prefer a milder flavor, SENSEO® coffee pods with a milder blend are available.
| Perhaps you pressed the 1-cup or 2-cup button twice.| This machine has Intensity Select. If you press the button twice, you get a smaller cup of stronger coffee.
Water leaks from the coffee machine.| You have not closed the lid properly.| Close the lid properly and lock the lever.
| You overfilled the water  reservoir.| Do not fill the water reservoir beyond the MAX level.
| The sieve in the center of the pod holder may be  clogged.| Check the pod holder. If the sieve is clogged, use a washing-up brush to unclog the sieve. If you cannot clean it properly with the  ashingup brush, put the pod holder in the machine and descale the machine according to the instructions.
| The sealing ring may be stuck under the edge of the distribution disk.| Check if the sealing ring is stuck under the edge of the distribution disk. If it is, pull it out from under the distribution disk carefully.
| Water drops on the worktop may be the result of placing the water reservoir or removing used coffee pods.| Check if the water drops on the worktop are not the result of placing or removing the water reservoir or removing used coffee pods. Make sure that you do not remove the water reservoir when the coffee machine is heating up. This may cause water that normally ends up in the water reservoir to leak out of the machine.
| | In all other cases, contact the Philips Consumer Care Center in your country.
| The machine has been stored in a room that was not frost-free.| Contact the Philips Consumer Care. Center in your country.
The appliance switches off automatically after 5 minutes.| | Appliances with this logo  ,   switch off automatically after 5 minutes of inactivity to save energy.

Flush before first use
Flush the machine before first use. After the flushing cycle (which only takes approx. 2 minutes), the machine is ready for brewing coffee.

Intensity Select (HD6556, HD6555, HD6554)
It is possible to brew even shorter stronger cups of coffee by double pressing the 1-cup or 2-cup button.

Special coffees
To brew a special coffee, place a cappuccino pod, a hot chocolate pod or another special coffee pod in the 2-cup pod holder and press the 1-cup button.

2x descaling, 2x rinsing
Descale the machine at least every 3 months. Use liquid SENSEO® descaler only. The descaling procedure consists of two descaling cycles and two flushing cycles. Each cycle lasts 5 minutes. Fill a jug with 1 liter of water, pour one half of the bottle in the jug and then pour the descaling mixture in the water reservoir. Press the 2-cup button several times until all descaling mixture is used up. You have to use 1 jug of descaling mixture for each descaling cycle. Use the 1-cup pod holder with a used pod or the thin descaling filter during the first descaling cycle and use the 2-cup pod holder with a used pod or the thick descaling filter during the second descaling cycle. Fill the water reservoir with fresh water and press the 2-cup button several times until the water reservoir is empty. Repeat this for the second flushing cycle. Do not interrupt the descaling cycles and do not switch off the machine before you have performed the two flushing cycles. Throw used pods or descaling filters away after use. For more information on why it is important to descale, when to descale and how to descale or which descaler to use, visit our website at www.philips.com/descale-senseo.

Automatic shut-off.

The appliance switches off automatically after 30 minutes. Appliances with this logo , switch off automatically after 5 minutes of inactivity to save energy.

© 2019 Koninklijke Philips Electronics N.V.
All rights reserved.
3000.037.4438.2 (08 /2019)

75% recycled paper

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals