Z-WAVE PLUS PAN33 In Wall Micro Switch Instruction Manual

June 5, 2024
Z-Wave Plus

Z-WAVE PLUS PAN33 In Wall Micro Switch

Introduction

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch Load On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light.

Safety Precautions and Installation

  • Avoid installing the unit in storming or raining weather.
  • Be sure to isolate or switch off power source before installing or maintenance.
  • Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse.

IMPORTANT

  • Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation.
  • Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods.

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.

Specification

Operating Voltage 100 -240VAC 50Hz-60Hz
Maximum Load Max. 6.5A (230Vac/120Vac) (Riesistive load)
Range Minimum 40m indoor 100m outdoor line of sight
Operating Temperature 0°C to 40°C
Humidity Up to 85% max.
Storage Temperature -20°C to 60°C
Location Indoor use only
Frequency Range 868.40MHz; 869.85MHz (EU)

908.40MHz; 916.00MHz (USA/Canada)

920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)

RF Maximum Power| +10dBm (Peak), -10dBm (Average)
OTA| Support
FCC ID| RHHPAN33
Dimensions| 47.5 x 39 x15.6 mm
Wire| 0.75mm², 18AWG

Troubleshooting

Symptom Cause of Failure Recommendation
The Switch not working and LED off 1.  The Switch is not connect

to the Main power

2.  The Switch break down

| 1.  Check power connections

2.  Don’t open up the Switch and

send it for repair.

The Switch LED| Check if the load connect| Set the ON/OFF switch of the
illuminating, but cannot control the ON/OFF

Switch of the attached load

| into the Switch has its own ON/OFF switch| attached load to ON
---|---|---
The Switch LED illuminating, but the detector cannot control

the Switch

| 1.  Not carry out association

2. Same frequency interference

| 1.  Carry out association

2.  Wait for a while to re-try

LED keep flashing continuously, but cannot control| Overload occurs| Remove the attached load or check max. load cannot exceed 85°C (230Vac/120Vac)

(Resistive load)

Installation Steps

  1. Connect PAN33 to AC N and L.
  2. Connect Load to NO1.
  3. Connect external Switch S1 and S2 to L.

For Instruction to http://www.philio-tech.com

All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage. Choosing a Suitable Locatio

  1. Do not locate the Module facing direct sunlight, humid or dusty place.
  2. The suitable ambient temperature for the Module is 0°C~40°C.
  3. Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
  4. After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.

Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off. The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/reset devices

Function Description LED Indication
No node ID The Z-Wave Controller does not allocate a node ID to the Switch.

2-second on, 2-second off
Add (Inclusion)| Have Z-Wave Controller entered inclusion mode.| One press one flash

※ To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode.
SmartStart| 1. To initiate the SmartSart process, please type in the first five digits of DSK string or scan the QR code. The QR Code can be found on PAN33 or in the box. Ex:

DSK: 18112-24021-58001-62259-

57092- 27453-08187-47408

2. PAN33 is supported with SmartStart, it can be added to Z-Wave™ network by scanning the Z-Wave™ QR code on the product.

3. Without further actions, PAN33 will be automatically included in a certified

Z-Wave™ Controller with SmartStart

inclusion ability in 10 minutes after it turned on.

|
Remove (Exclusion)| Have Z-Wave Controller entered exclusion mode.| One press one flash

※ To support handling of the device when already installed the external switch can be

used for inclusion or exclusion for 3 minutes after power up.

Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode.
Node ID has been excluded.| 2s On, 2s Off (No node ID)
Reset| Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode.| One press one flash
| Within 1 second, press Include button of PAN33 again for 5 seconds.|
---|---|---
IDs are excluded.| 2s On, 2s Off (No node ID)
※ Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID allocated by Z-Wave Controller means exclusion.

※ Failed or success in including/excluding the node ID can be viewed from the Z-Wave

Controller.

※ Sometimes people are not easy to execute exclusion or inclusion especially when PAN33 already installed in a wall box. To solve this issue, PAN33 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when

first time connect to main power.

LED Indication

There is a LED for identify function in the front case. PAN33 support the indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05. To distinguish what mode the switch is in, view from the LED for identification.

State Type LED Indication
Normal When PAN33 switch On the LED will lights up, when PAN33 switch Off the

LED will lights off.
No node ID| Under normal operation, when the Switch has not been allocated a

node ID, the LED flashes on and off alternately at 2-second intervals.

Overload| When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.2 second intervals. Overload state can be cleared by disconnect and reconnect the Switch to the main power.

Installation

Z-WAVE-PLUS-PAN33-In-Wall-Micro-Switch-2

  1. Put the in wall switch into a wall box and connect the AC power wire L, N to PAN33 connector L, N.
  2. Connect the wall switch to the PAN33 as Fig1.
  3. There are 3 mode PAN33 can be configured to match different kind of wall switch, please refer to 3-1 External switch mode which described in next section of this user manual
  4. If Edge-Toggle mode has been set, and the S1/S2 is connect to normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1.

Programming

Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z- Wave system. 1-1 BASIC_GET / BINARY_SWITCH_GET PAN33 will report ON when relay 1 is ON, or report OFF when relay1 is OFF.

  • Basic Get Command: [Command Class Basic, Basic Get]
  • Basic Report Command:
  • Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
  • Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get] Binary Switch Report Command: Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 255(0xFF)]

BASIC_SET / SWITCH_BINARY_SET
PAN33 will turn on or off upon receipt of the following commands from a Z-Wave Controller.

  • [Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: both the load attached to the Switch turns on.
  • [Command Class Basic, Basic Set, Value = 0(0x00)]: both the load attached to the Switch turns off.
  • [Command Class Basic, Basic Set, Value = 0(0x00)]: both the load attached to the Switch turns off.
  • [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: both the load attached to the Switch turns off.

Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to the associated Z-Wave devices. It supports one groups and every group has five nodes support. Group1 is called Lifeline which support SWITCH_BINARY_REPORT、NOTIFICATION_REPORT、 INDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
Auto report to Grouping 1(Maximum Node 5)
1-1 On/Off Event Report When “on” or “off” state has been changed (ex. Press S1 or S2 or include on/off button), it will send Binary Switch Report to the nodes of Group1.

  • ON:[Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)]
  • OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]

Overload Notification report command
When PAN33 detect the overload, it will send Notification Report to Group1. The content of Notification Report

Z-Wave’s Configuration

Configura tion Paramete

r

| Function| Size (Byte)| Value| Unit| Default| Description
---|---|---|---|---|---|---
1| External switch mode| 1| 1-3| | 1| 1:Edge mode 2:Pulse mode 3:Edge-Toggle

mode

2| Restore switch state mode| 1| 0-2| | 1| 0 : Switch off 1 : Last switch
| | | | | | state

2 : Switch on

---|---|---|---|---|---|---
3| Manual On/Off mode| 1| 0-1| | 1| 0:Disable

manual On/Off

| | | | | 1:Enable
| | | | | manual On/Off
4| LED indication mode| 1| 1-3| | 1| 1:Show switch state

2:Show night

| | | | | mode

3 : One flash mode

5| Manual Switch Report mode| 1| 0-1| | 1| 0 : Disable

1 : Enable

External switch mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. Edge mode: this mode is suitable for the bi- stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1. If the PAN33 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1. Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1. 3-2 Restore switch state mode Whenever the AC power return from lost, PAN33 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.

Manual On/Off ModE
The On/Off function of S1、S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation won’t be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state.

LED indication Mode:
Show switch state:LED on for switch on and off for switch off. The default value is Show switch state. 3-4-2 Show night mode:LED off for switch on and on for switch off. 3-4-3 One Flash mode:When the state of switch changes, LED will be on only

Firmware update over the air (OTA)

PAN33 is based on 700 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.

Command Classes
The Switch supports Command Classes includin

Command Class Version Required Security Class
Z-Wave Plus Info 2 None
Security 0 1 None
Security 2 1 None
Supervision 1 None
--- --- ---
Transport Service 2 None
Association 2 Highest granted Security Class
Association Group Information 3 Highest granted Security Class
Basic 2 Highest granted Security Class
Binary Switch 2 Highest granted Security Class
Configuration 4 Highest granted Security Class
Device Reset Locally 1 Highest granted Security Class
Firmware Update Meta Data 5 Highest granted Security Class
Indicator 3 Highest granted Security Class
Manufacturer Specific 2 Highest granted Security Class
Multi Channel Association 3 Highest granted Security Class
Notification 8 Highest granted Security Class
Powerlevel 1 Highest granted Security Class
Version 3 Highest granted Security Class

Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

FCC Interference Statement

This equipment has been tested and found to comply with the limit’s for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.