SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap Assembly Installation Guide

June 7, 2024
SYMMONS

SYMMONS Origins logo

Origins Trim Series
Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap Assembly
Installation & Operation Instructions

Model Numbers

TRIM ONLY
9600-P-TRM
Shower Valve Trim
9600-PLR-TRM
Shower Valve Trim
9601-P-TRM
Shower Trim
9601-PLR-TRM
Shower Trim
9602-P-TRM
Tub/Shower Trim
9602-PLR-TRM
Tub/Shower Trim
9603-P-TRM
Hand Shower Trim
9603-PLR-TRM
Hand Shower Trim
9604-P-TRM
Tub/Hand Shower Trim
9604-PLR-TRM
Tub/Hand Shower Trim
9605-P-TRM
Shower/Hand Shower Trim
9605-PLR-TRM
Shower/Hand Shower Trim
9606-P-TRM
Tub/Shower/Hand Shower Trim
9606-PLR-TRM
Tub/Shower/Hand Shower Trim| TRIM, TA-10, T-12A
9600PTRMTC
Shower Valve Trim
9600PLRTRMTC
Shower Valve Trim
9601PTRMTC
Shower Trim
9601PLRTRMTC
Shower Trim
9602PTRMTC
Tub/Shower Trim
9602PLRTRMTC
Tub/Shower Trim
9603PTRMTC
Hand Shower Trim
9603PLRTRMTC
Hand Shower Trim
9604PTRMTC
Tub/Hand Shower Trim
9604PLRTRMTC
Tub/Hand Shower Trim
9605PTRMTC
Shower/Hand Shower Trim
9605PLRTRMTC
Shower/Hand Shower Trim
9606PTRMTC
Tub/Shower/Hand Shower Trim
9606PLRTRMTC
Tub/Shower/Hand Shower Trim
---|---

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap
AssemblySYMMONS
Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
TRIMSYMMONS Origins
Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
Compliance Compliance

Symble

  • ASME A112.18.1/CSA B125.1

Warranty
Limited Lifetime – to the original end purchaser in consumer/residential installations.
5 Years – for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete warranty information.
Go to www.symmons.com/register to register your Symmons product.

Recommended Tools

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap
Recommended Tools

Dimensions

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap
fig2SYMMONS Origins
Trim Series with TA-10 Flow Control Spindle & T-12A Cap
fig2.0

|

Measurements

---|---
A| 6-3/8″. 162 mm
B| 3″. 76 mm
C| Diverter Valve Hole Size
Min. 0 3″. 76 mm
Max. 0 3-1/4″. 83 mm
D| 3 1/2″. 89 mm
E| Male 1/2″ NPT fitting must
protrude 3/8″ from
the finished wall
F| Ref. 10″. 254 mm
G| Ref. 77″. 1956 mm
H| Shower Valve Hole Size
Min. 0 3″. 76 mm
Max. 0 4″. 102 mm
I| 2-7/8″. 73 mm
| Rough-in
2-3/8″ ± V2″. 60 mm ± 13 mm
K| 9600, 9601, 9603, 9605:
Ref. 42″. 1067 mm
9602, 9604, 9606:
Ref. 32″. 813 mm
L| Male 1/2″ NPT fitting must protrude 4″ from
the finished wall
M| 5-1/2″. 140 mm
N| 0 2-1/2″. 64 mm
0| 0 2-3/4″. 70 mm
P| 0 4-1/4″. 108 mm
0| 0 2-1/2″. 64 mm
R| 0 5-3/4″. 146 mm
S| 0 2-1/2″. 64 mm
T| 0 3-1/8″. 79 mm
U| 36″. 914 mm
V| 39″. 991 mm
W| 2-7/8″. 73 mm
X| 2-1/8″. 54 mm
Y| 3-5/8″. 92 mm
Z| 3-3/8″. 86 mm

Notes:

  1. Valve body and piping not included and shown as reference only.
  2. Plaster shield (p/n T-176) for drywall, plaster or other type walls 1/2″ or greater.
  3. All dimensions measured from nominal rough-in (see J as reference).
  4. Dimensions subject to change without notice.

Parts Breakdown (Model Numbers Ending in TRMTC)

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
Parts Breakdown

Item Description Part Number
1 Cap Assy. T-12A
2 Flow Control Spindle TA-10

IMPORTANT: Model numbers ending in TRMTC coordinate with Temptrol pressure-balancing valves ordered with Test Cap.  The Test Cap is used to allow pressurization of the system. Do not remove test cap from the valve during wall construction,  installation of valve or pressurization of the system.

Installation – Remove Test Cap (Model Numbers Ending in TRMTC)

Flow control spindle (TA-10) and cap assembly (T-12A) will come factory assembled for all model numbers ending in TRMTC.  When ready to remove Test Cap and install trim, follow the instructions below:

  1. Check for leaks around the valve assembly and all pipe fittings.
  2. Remove test cap from valve (FIGURE 4.1).
  3. If the system is dirty, flush the valve.
  4.  Thread flow control spindle and cap assembly into the valve body. Turn clockwise to secure to valve (FIGURE 4.2).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap
-fig4.0

Installation – Adjust Packing Nut (Model Numbers Ending in TRMTC)

  1.  Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.
  2. Place handle overflow control spindle.
  3.  Tighten packing nut for positive frictional resistance as the handle is rotated from shut-off position across adjustment range

Installation – Setting Limit Stop Screw (Model Numbers Ending in TRMTC)

The temperature limit stop screw limits valve handle from being turned to the maximum position resulting in excessive hot water discharge temperatures.
WARNING: Failure to adjust the limit stop screw properly may result in serious scalding.

  1. Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.
  2.  Place the handle on the flow control spindle and open the valve to the maximum desired temperature.
  3. Turn limit stop screw clockwise until it seats.

Parts Breakdown

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
Parts fig 7SYMMONS Origins Trim Series with TA-10 Flow Control Spindle &
T-12A Cap - Parts fig7.0

*Order in-line vacuum breaker (EF-109) for hand shower systems without dual checks.

Replacement Parts


Item

| Description|

Part Number

A| Showerhead| 4-141
B

C

| Shower Arm

Flange

| 300S
D| ‘PLR’ Handle| RTS-063
E| Dome Cover| T-19
F

G

| Diverter Escutcheon

Screws

| 96-66-DIV-ESC
H| ‘P’ Handle| RTS-061
I

J

| Shower Escutcheon

Screws

| Standard: 9600-P-ESC

Brass: 9600-P-B-ESC

K

K1

| Tub Spout

Diverter Tub Spout

| 060

054

L| Hand Shower| ADACHS
M| Wall Elbow| 40A
N| Slide Mechanism| FP-SM6
0| 60″ Hose| RTS-045

Notes:

  1.  Append appropriate suffix for a premium finish.
  2. Append appropriate flow rate to the showerhead or hand shower for low flow.
  3. Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall. Leave an opening on the bottom of escutcheons for weep hole.
  4.  Apply plumber tape to all threaded connections.

Installation – Shower Valve Trim

  1. Secure large shower escutcheon to Temptrol pressure-balancing valve using mounting screws (FIGURE 8.1).
  2. Install dome cover by turning clockwise (FIGURE 8.2).
  3. Install ‘P’ handle to the shower valve. Secure with set screw. Install plug button (FIGURE 8.3).
  4.  Install ‘PLR’ handle to the shower valve. Secure with set screw (FIGURE 8.4).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
Parts 8

 Installation – Diverter Valve Trim

  1.  Secure small diverter escutcheon to Symmons diverter valve using mounting screws (FIGURE 9.1).
  2. Install dome cover by turning clockwise (FIGURE 9.2).
  3. Install the handle to the diverter valve. Secure with set screw(FIGURE 9.3).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
Parts 9

Installation – Showerhead & Tub Spout

  1. Attach arm and flange to shower pipe. Turn clockwise to tighten (FIGURE 10.1).
  2. Install showerhead to shower arm. Turn clockwise to tighten (FIGURE 10.2).
  3. Install tub spout to stub out pipe. Turn clockwise to tighten (FIGURE 10.3).

diagramSYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A
Cap - fig 10

Installation – Slide Bar Assembly

  1. Remove slide bar ends from slide bar flanges. Using flanges as a guide, drill 1/8″ pilot holes into studs or wood blocking. With slide bar in position, secure to wall using screws. Attach slide bar ends to bar flanges (FIGURE 11.1).

  2. Remove the screw cap from slide mechanism (FIGURE 11.2).

  3.  Remove the wand holder from the slide mechanism (FIGURE 11.3).

  4.  Remove lever handle from slide mechanism (FIGURE 11.4).

  5.  Install slide mechanism components to slide bar following STEPS 11.2 – 11.4 in reverse. Flat edge on (N1) and (N2) must be aligned. Arrows on (N1) and (N3) identify the bottom side (FIGURE 11.5).
    Note: Adjust the screw cap for ease of movement of the slide assembly.

  6. Press tabs on wall elbow flange. Install wall elbow to pipe fitting. Turn clockwise to secure (FIGURE 11.6).

  7. Attach small end of hand shower hose to wall elbow.
    Turn clockwise to tighten (FIGURE 11.7).

  8. Attach large end of hand shower hose to hand shower wand. Turn clockwise to tighten (FIGURE 11.8).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
fig 11SYMMONS Origins
Trim Series with TA-10 Flow Control Spindle & T-12A Cap
-11.2SYMMONS Origins
Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
11.4

Operation (Temperature Control)

  1. Turn shower handles counter-clockwise approximately 1/4 turn to put the valve in cold position (FIGURE 12.1).
  2. Turn shower handles counter-clockwise approximately 1/2 turn to put the valve in a warm position (FIGURE 12.2).
  3.  Turn the shower handle counter- clockwise approximately 3/4 turn to put the valve in hot position (FIGURE 12.3).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -fig
12

Operation (Dual Outlet Diverter Control)

Note: Additional handle positions for the same output are illustrated.

  1.  The cartridge is factory set to divert to function 1 (FIGURE 13.1).
  2.  Turn the handle to position 2 to divert to function 2 (FIGURE 13.2).
  3. Turn the handle to position 3 to share functions 1 and 2 (FIGURE 13.3).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap -
fig 13

 Operation (Triple Outlet Diverter Control)

  1. Cartridge is factory set to divert to function 1 (FIGURE 14.1).
  2.  Turn handle to position 2 to divert to function 2 (FIGURE 14.2).
  3.  Turn handle to position 3 to divert to function 3 (FIGURE 14.3).
  4. Turn handle to position 4 to share functions 2 and 3 (FIGURE 14.4).
  5. Turn handle to position 5 to share functions 1 and 3 (FIGURE 14.5).
  6. Turn handle to position 6 to share functions 1 and 2 (FIGURE 14.6).

SYMMONS Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap
-14

Troubleshooting Chart Problem

Problem Cause Solution
Finish is spotting. Elements in the water supply may cause
water staining on the finish. Clean finished trim area with a soft

cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.

WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Symmons Industries, Inc.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SYMMONS User Manuals

Related Manuals