Munters Bird Scale User Manual
- June 7, 2024
- Munters
Table of Contents
RBS 3H Bird Scale
Manual for use and maintenance
Ag/MIS/ImEn-2702-02/19 Rev 1.0 P/N: 116266 Rev 1.0
RBS 3H
Manual for use and maintenance
Rev 1.0; 03/2019 Ag/MIS/ImEn-2702-02/19 Rev 1.4 (MIS)
This manual for use and maintenance is an integral part of the apparatus
together with the attached technical documentation.
This document is destined for the user of the apparatus: it may not be
reproduced in whole or in part, committed to computer memory as a file, or
delivered to third parties without the prior authorization of the assembler of
the system. Munters reserves the right to effect modifications to the
apparatus in accordance with technical and legal developments.
Introduction
Disclaimer
Munters reserves the right to make alterations to specifications, quantities,
dimensions, etc. for production or other reasons, subsequent to publication.
The information contained herein has been prepared by qualified
experts within Munters. While we believe the information is accurate and
complete, we make no warranty
or representation for any particular purposes. The information is offered in
good faith and with the
understanding that any use of the units or accessories in breach of the
directions and warnings in this
document is at the sole discretion and risk of the user.
Introduction
Congratulations on your excellent choice of purchasing an RBS-3H In order to realize the full benefit from this product it is important that it is installed commissioned and operated correctly. Before installation or using the fan, this manual should be studied carefully. It is also recommended that it is kept safely for future reference. The annual is intended as a reference for installation, commissioning, and day-to-day operation of the Munters Controllers.
Notes
Date of release: July 2010 Munters cannot guarantee to inform users about the changes or to distribute new manuals to them. All rights reserved. No part of this manual may is reproduced in any manner whatsoever without the expressed written permission of Munters. The contents of this manual are subject to change without notice.
Installing the RBS 3H
The RBS-3H hanging scale is assembled in simple, easy-to-follow steps as seen in the following section. It is adjustable, must be hung from above, and is collapsable. The poles slide into one another for ease of transport and storage. The RBS-3H hanging scale is composed of the following components:
- Pole A
- Pole B
- Base Plate
- Transducer
POLE A
Pole A, 151.5cm/59.4inches, is the larger in diameter of the poles. It has two
thumb screws near the open
end. The other end connects to the plate. Pole B is nested inside. Refer to
Figure 2.
POLE B
Pole B,154.5cm/160.8inches, stores inside Pole A, and has a hook at one end.
Pole B connects to the transducer. Refer to Figure 3.
BASEPLATE
The base plate is a five-side polygon base constructed of heavy corrugated metal and is used to place the birds for weighing. The base plate is composed of the following sub-components:
- Plate base
- Bolt
- Nut
- Metal washer
- Two square flat metal pieces (used for ballast)
TRANSDUCER
The transducer converts weight from the RBS-3H hanging scale into data that is input and read by a connected digital scale. The RBS-3H transducer is suspended from above and Pole A hooks onto the ring. Refer to Figure 4.
Assembly
This section contains the following:
- General Assembly
- Detailed Assembly
GENERAL ASSEMBLY
A general view of the RBS-3H assembly is as follows:
1.Position transducer with eyebolt.
2.Connect Pole A to base.
3.Extend and position Pole B, hook onto the transducer.
4.Connect transducer data plug with computer/electronic scale device
DETAILED ASSEMBLY
The RBS-3H hanging scale package contains poles (A and B), a base plate assembly, and a transducer (device and cable). Refer to Figure 5.
Remove Pole A and loosen the thumbscrews. Refer to Figure 6.
Figure 5: Releasing Pole A Thumb Screws
Extend Pole B to the desired position and set aside. Refer to Figure 7.
Figure 6: Extending Pole B from Pole A
Use a wrench to release the base plate bolt from the nut. Refer to Figure 8.
Figure 7: Release Base Plate Bolt
Invert the base plate bolt so that it extends upwards out of the base plate.
Position Pole A onto the base plate bolt and screw tightly. Refer to Figure 9.
Figure 8: Connect Pole A to Base Plate
Connect the pole assembly onto the hanging transducer and connect the data cable to the computer/weight scale. Refer to Figure 10.
Figure 9: Connect Pole Assembly to Transducer
Figure 10: RBS-3H Hanging Scale Assembled
Warranty
Warranty and technical assistance Munters products are designed and built to
provide reliable and satisfactory performance but cannot be guaranteed free of
faults; although they are reliable products they can develop unforeseeable
defects and the user must take this into account and arrange adequate
emergency or alarm systems if failure to operate
could cause damage to the articles for which the Munters plant was required:
if this is not done, the user is fully responsible for the damage which they
could suffer. Munters extends this limited warranty to the first purchaser and
guarantees its products to be free from defects originating in manufacture or
materials for one year from the date of delivery, provided that suitable
transport, storage, installation, and maintenance terms are complied with. The
warranty does not apply if the products have been repaired without express
authorization from Munters, or repaired in such a way that, in Munters’
judgment, their performance and reliability have been impaired, or incorrectly
installed, or subjected to improper use. The User accepts total responsibility
for incorrect use of the products. The warranty on products from outside
suppliers fitted to the RBS, (for example antennas, power supplies, cables,
etc.) is limited to the conditions stated by the supplier: all claims must be
made in writing within eight days of the discovery of the effect and within 12
months of the delivery of the defective product. Munters has thirty days from
the date of receipt in which to take action and has the right to examine the
product at the customer’s premises or at its own plant (carriage cost to be
borne by the customer). Munters at its sole discretion has the option of
replacing or repairing, free of charge, products which it considers defective,
and will arrange for their despatch back to the customer carriage paid. In the
case of faulty parts of small commercial value which are widely available
(such as bolts, etc.) for urgent despatch, where the cost of carriage would
exceed the value of the parts, Munters may authorize the customer exclusively
to purchase the replacement parts locally; Munters will reimburse the value of
the product at its cost price.
Munters will not be liable for costs incurred in demounting the defective
part, or the time required to travel to the site, and the associated travel
costs. No agent, employee or dealer s authorized to give any further
guarantees or to accept any other liability on Munters’ behalf in connection
with other Munters products, except in writing with the signature of one of
the Company’s Managers.
WARNING: In the interests of improving the quality of its products and services, Munters reserves the right at any time and without prior notice to alter the specifications in this manual.
The liability of the manufacturer Munters ceases in the event of:
- dismantling the safety devices;
- use of unauthorized materials;
- inadequate maintenance;
- use of non-original spare parts and accessories.
Barring specific contractual terms, the following are directly at the user’s expense:
- preparing installation sites;
- providing an electricity supply (including the protective equipotential bonding (PE) conductor, in accordance with CEI EN 60204-1, paragraph 8.2), for correctly connecting the equipment to the mains electricity supply;
- providing ancillary services appropriate to the requirements of the plant on the basis of the information supplied with regard to installation;
- tools and consumables required for fitting and installation;
- lubricants necessary for commissioning and maintenance.
It is mandatory to purchase and use only original spare parts or those recommended by the manufacturer. Dismantling and assembly must be performed by qualified technicians and according to the manufacturer’s instructions. The use of non-original spare parts or incorrect assembly exonerates the manufacturer from all liability. Requests or technical assistance and spare parts can be made directly to the nearest Munters office. A full list of contact details can be found on the back page of this manual.
Munters Israel
18 HaSivim Street
Petach-Tikva 49517, Israel
Telephone: +972-3-920-6200
Fax: +972-3-924-9834
Australia Munters Pty Limited, Phone +61 2 8843 1594,
Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050,
Canada Munters CorporationLansing, Phone +1 517 676 7070,
China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481
121,
References