Z-Wave Siren User Manual
- June 7, 2024
- Z-Wave
Table of Contents
- Introduction
- Add the Siren to Z‐Wave Network
- Remove the Siren from Z‐Wave Network
- Restore the Siren to Factory Default Settings
- Associations (Association Command Class Version 2)
- Advanced Configuration
- 5. The settings for DOORBELL MUSIC MODE defines by Param #3, #4, and #6.
- Command Class Interact
- Battery Check Command
- LED Color Indicator
- Command Classes
- SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Siren User Guide
Introduction
In the front casing, there is a button that is used to carry out include, exclude or reset factory default settings on PCB Board.
When power is first supplied, the LED will flash on and off alternately at one-second intervals within 5 seconds if the detector has not been added to a Z‐Wave network. Please get familiar with the terms below before starting the operations.
This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
Manufacture ID: | 0x0258 |
---|---|
Product ID: | 0x0088 (US |
Product ID: | 0x1088 (EU) |
Add the Siren to Z‐Wave Network
- Remove the siren cover.
- Make sure the siren is powered.
- Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
- Press the button three times within 1.5 seconds, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Note: If the siren has not been added to the Z‐wave network, the siren
will enter inclusion mode
automatically when it is powered on. You should let the controller enter into
inclusion first
before powering on the siren in order to run this function.
Remove the Siren from Z‐Wave Network
- Remove the siren cover.
- Make sure the siren is powered.
- Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
- Press the button three times within 1.5 seconds, the device will enter exclusion mode.
Restore the Siren to Factory Default Settings
The reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the siren to factory default settings.
- Remove the device cover.
- Make sure the siren is powered.
- Press and hold the button for 10 seconds, led will blink once.
- Release the button.
Note: To use the reset procedure only when the primary controller is missing or inoperable.
Associations (Association Command Class Version 2)
This Siren supports 3 groups; each group supports a max of 5 associated nodes. This siren can identify some z‐wave notification sensors such as Motion Sensor, Door/Window Sensor, Water Leakage Sensor, Smoke Sensor, and so on. If these sensors associate this siren to their lifeline group or another group that supports NOTIFICATION_REPORT, the siren will play different music when the sensor is triggered.
GROUP 1 is a lifeline service assigned to Siren status. It enables the
Siren to send reports and readings to Z‐Wave Controller or Z‐ Wave Gateway
whenever the sensor is triggered. This Group
Support:
SWITCH_BINARY_REPORT,
NOTIFICATION_REPORT, BATTERY_REPORT,
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows for Send Binary Switch Report to associated devices
in this group. This Group
Support:
SWITCH_BINARY_REPORT
GROUP 3 allows for Send Notification to associated devices in this
group. This Group Support:
NOTIFICATION_REPORT
Advanced Configuration
This Siren supports 10 music for customer selecting their favorite music.
1. Configure Alarm Music Volume
This parameter defines the output volume when the siren plays doorbell music.
Door Bell music volume is divided into 3 stages, Low (Parameter is set to
‘1’), Middle (Parameter is set to ‘2’), High (Parameter is set to ‘3’). The
default value is ‘3’. This Siren supports 10 music for customer selecting
their favorite music.
1. Configure Alarm Music Volume This parameter defines the output volume when
the siren plays doorbell music. Door Bell music volume is divided into 3
stages, Low (Parameter is set to ‘1’), Middle (Parameter is set to ‘2’), High
(Parameter is set to ‘3’). The default value is ‘3’.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
1 | 1 | 1 ~ 3 | 3 |
2. Configure Alarm Music Duration Time
This Parameter defines the alarm music duration time when the siren receives
an alarm sensor notification report or an alarm command from the controller.
The duration time is divided into 5 stages: Siren is not on (Parameter is
set to ‘0’), 30 seconds (Parameter is set to ‘1’), 1 minute (Parameter is
set to ‘2’), 5 minutes (Parameter is set to ‘3’) and Siren is always on until
battery is dead (Parameter is set to ‘0xFF’). The default value is ‘2’.
The value for this parameter is an unsigned value.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
2 | 1 | 0 x00~ 0x03, 0xFF | 2 |
3. Configuring Door Bell Music Duration Tim
This parameter defines the doorbell music duration time when the siren
receives a door/window sensor notification report or an alarm command
(BASIC_SET = 0x02) from the controller. The doorbell music will be played
always if this parameter is set to ‘0xFF’. The doorbell music will not be
played if this parameter is set to ‘0’. Other values are the doorbell music
playing duration time. Unit: Time.
The value for this parameter is an unsigned value.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
3 | 1 | 0x00~0xFF | 1 |
4. Configure Door Bell Music Volume
This parameter defines the output volume when the siren plays alarm music.
Door Bell music volume is divided into 3 stages, Low (Parameter is set to
‘1’), Middle (Parameter is set to ‘2’), High(Parameter is set to ‘3’). The
default value is ‘1’.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
4 | 1 | 1 ~ 3 | 1 |
5. Configure Alarm Music Index
This parameter defines the alarm music index for siren play different music
when
an alarm occurs. There are 10 different music for user selection.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
5 | 1 | 1 ~ 10 | 10 |
6. Configure Door Bell Music Index
This parameter defines the doorbell music index for siren play different music
when
an alarm occurs. There are 10 different music for user selection.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
6 | 1 | 1 ~ 10 | 9 |
7. Configure Default Siren On Mode
This parameter defines the default music index, volume, and duration time for
the siren. This parameter can be selected between ALARM MUSIC and
DOORBELL MUSIC. The settings for ALARM MUSIC MODE defines by Param #1, #2, and
5. The settings for DOORBELL MUSIC MODE defines by Param #3, #4, and #6.
If the parameter is set to ‘1’, the siren will select ALARM MUSIC MODE to play
music;
If the parameter is set to ‘2’, the siren will select DOORBELL MUSIC MODE to
play music;
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
7 | 1 | 1 ~ 2 | 1 |
8. Configure Alarm Led Enable
This parameter defines the default led enable status when the siren is on for
ALARM MUSIC MODE.
If the parameter is set to ‘0’, led will be disabled.
If the parameter is set t0 ‘1’, led will be enabled. When the siren is on, the
led will blink.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
8 | 1 | 0, 1 | 1 |
9. Configure Door Bell Led Enable
This parameter defines the default led enable status when the siren is on for
DOORBELL MUSIC MODE.
If the parameter is set to ‘0’, led will be disabled.
If the parameter is set t0 ‘1’, led will be enabled. When the siren is on, the
led will blink.
Parameter Number | Size | Available Settings | Default |
---|---|---|---|
9 | 1 | 0, 1 | 1 |
Command Class Interact
Binary Switch Command Class
A siren can be turned on and off by COMMAND_CLASS_SWITCH_BINARY Which music
will be play
by the siren is decided by advance configuration parameter #5. When Siren
stops play alarm music, it
will send a SWITCH_BINARY_REPORT = 0x00 to the controller.
Siren Alarm On:
Command Class: COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0xFF
Siren Alarm Off:
Command Class: COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0x00
Basic Command Class
The Functions of BASIC_SET = 0x00 And BASIC_SET = 0xFF are same to Binary
Switch Command Class.
Indicator Command Class
The INDICATOR_SET Value is indicated that which music will be played. For
example INDICATOR_SET = 0x01, Siren will play the first music.
Command | Music Index in Memery | laying Volume And Tim Pe |
---|---|---|
INDICATOR _SET = Ox01 | 1 | Defined By Param #3, #4 |
INDICATOR _SET = 0x02 | 2 | Defined By Param #3, #4 |
INDICATOR _SET = 0x03 | 3 | Defined By Param #3, #4 |
INDICATOR _SET = 0x04 | 4 | Defined By Param #3, #4 |
INDICATOR _SET = Ox05 | 5 | Defined By Param #3, #4 |
INDICATOR _SET = 0x06 | 6 | Defined By Param #3, #4 |
INDICATOR _SET = 0x07 | 7 | Defined By Param #3, #4 |
INDICATOR _SET = Ox08 | 8 | Defined By Param #3, #4 |
INDICATOR _SET = Ox09 | 9 | Defined By Param #3, #4 |
INDICATOR_SET = OxOA | 10 | Defined By Param #3, #4 |
Other INDICATOR_SET values are invalid for this siren.
Notification Command Class
If Siren receives a command from associated devices or controllers to play
any music, the siren will send an active notification to the controller. If
Siren stops play music, it will send a no-active notification to the
controller.
Siren Active Notification Report:
Command Class : COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type :NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_ACTIVE
Siren No Active Notification Report:
Command Class : COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_NO_EVENT
Battery Check Command
The users can also enquire about the battery status of the siren by sending the BATTERY_GET command. Once the siren receives the command, it will return the BATTERY_REPORT command. The siren will send BATTERY_LEVEL = 0xFF command to the Z‐Wave Controller to inform that the siren is in dead battery status, otherwise, the BATTERY_LEVEL value range is 0% to 100%.
LED Color Indicator
LED Color | Led Display Status | Description |
---|---|---|
Red | Blink 5 Times(1s Interval) | Power on and Not Add in Z‐Wave Network |
Blink 5 Times(500ms Interval) | Press Button tripled: 1, Enter Inclusion Mode |
2, Enter Exclusion Mode 3, Send Node Info
Blink 5 Times(300ms Interval)| ) Power on and Already Add in a Z‐Wave Network
Blink 1 Time| Press the Button Long Time, Reset the Plug to restore default
settings
Turn on with rotation| Alarm on
Command Classes
This siren supports Command Classes as Below:
COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
COMMAND_CLASS_VERSION (V2)
COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
COMMAND_CLASS_POWERLEVEL (V1)
COMMAND_CLASS_BATTERY (V1)
COMMAND_CLASS_ASSOCIATION (V2)
COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
COMMAND_CLASS_WAKE_UP (V2)
COMMAND_CLASS_SWITCH_BINARY (V1)
COMMAND_CLASS_NOTIFICATION (V8)
COMMAND_CLASS_CONFIGURATION (V1)
*COMMAND_CLASS_INDICATOR (V1)
SPECIFICATIONS
Battery type: | 2 × CR123 (3.0V) |
---|---|
Power Consumption: | 2W |
Max Current: | 35mA (In Radio Transmitter Mode) |
EU Standards Compliance: | 500mA (In Siren On and Max Volume Mode) |
Radio Protocol: | Z‐Wave |
Radio Frequency: | EU – 868.4MHz |
US – 908.4MHz
Valid Range:| Up to 80m outdoors
Operational Temperature:| Up to 40m indoors (Depending on terrain and building
structure) 0 – 40 ℃
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>