Z-WAVE PAT02 3-in-1 Flood Multisensor User Manual
- June 5, 2024
- Z-Wave
Table of Contents
Z-WAVE PAT02 3-in-1 Flood Multisensor
The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-WaveTM technology. It is the Z-WaveTM plus product, it support the security, OTA… Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
The device adopt the Z-WaveTM 500 series chip, when your Z-WaveTM network system is all made by Z-WaveTM 500 series devices. The network system will have the advantages as below.
- Concurrent multi-channel support reduces external interference.
- Better RF range, improve about 10 meters in indoor.
- Support 100 Kbps transmit speed, speed up communication.
Function Compare A/B/C
| Flood| Temperature| Humidity
---|---|---|---
PAT02-A| V| V| V
PAT02-B| | V| V
PAT02-C| V| |
Specification
Power | 3VDC (CR123A lithium battery) |
---|---|
RF distance | Min. 40M indoor, |
100M outdoor line of sight,
RF Frequency
| 868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US) 920.9MHz, 921.7MHz, 923.1MHz
(TW/KR/Thai/SG)
RF Maximum Power| +5dBm
Function| Flood, temperature and humidity
Location| indoor use only
Operation temperature| -10oC to 40oC
Humidity| 85%RH max
FCC ID| RHHPAT02
Specifications are subject to change and improvement without notice
Troubleshooting
Symptom | Cause of Failure | Recommendation |
---|---|---|
The device can not join to Z-Wave™ network | The device may in a Z- Wave™ | |
network. | Exclude the device then include again. |
For Instruction to http:// www.philio-tech.com
Battery Installation
When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V.The way to open the front cover please press the top position, to release the cover.
Replace the new battery and install the cover back.
- Put the front cover bottom, and press down.
- Push the front cover top.
CAUTION
- replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types);
- disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas;
- a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gasThe marking information is located at the bottom of the apparatus.
Add to/Remove from Z-WaveTM Network
There are one tamper keys in the back side of the device, It can add, remove,
reset or association from the Z-WaveTM network.In the first time, add the
device into the Z-WaveTM network. First, make sure the primary controller is
in the add mode. And then power on the device, just take out the insulation
Mylar in the back side of the device. The device will auto start the NWI
(Network Wide Inclusion) mode. And it should be included in 5 seconds. You
will see the LED light ON one second.
Notice:
Including a node ID allocated by Z-WaveTM Controller means “Add” or
“Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means
“Remove” or “Exclusion”.
Function | Description |
---|
Add
| 1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-WaveTM Controller about 20 seconds.
Remove
| 1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
Node ID has been excluded.
Reset
| Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th
| pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.
---|---
Association
| 1. Have Z-WaveTM Controller entered association mode.
2. Pressing tamper key three times within 1.5 seconds to enter the association mode.
Note: PAT02-1A and PAT02-1C are support 2 groups, and PAT02-1B only support 1 group. The group 1 is for receiving the report message, like triggered event, temperature, humidity etc. The group 2 is for the light control, the device will send the “Basic Set” command
to this group. And each group support 8 nodes maximum.
· Failed or success in add/remove the node ID can be viewed
from Z-WaveTM Controller.
Notice 1:
Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM network
Notice 2:
When the device into NWI mode, the sensor functionality will useless. The NWI
mode will timeout after 30 seconds. You can press the tamper key 3 times to
abort the NWI mode.
Z-WaveTM Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification” message
to the network, and wake-up 10 seconds for receive the setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum setting is 120
hours. And the interval step is 30 minutes.Press the tamper key once. The
device will wake-up 10 seconds.
Z-WaveTM Message Report
When the flood triggered the device will report the trigger event and also
report the battery status, temperature and humidity. In default the device
will using Notification Report to represent the trigger event, it can be
changed to Sensor Binary Report by setting the configuration NO. 7 Bit4 to 1.
Fl o od Report: (PAT02-A, PAT02-C)
When the flood triggered, the device will unsolicited to send the report to
the nodes in the group 1.
Notification Report (V4)
Notification Type: Water Alarm (0x05)
Event: Water Leak detected, Unknown Location (0x02)
Sensor Binary Report (V2)
Sensor Type: Water (0x06) Sensor Value: 0xFF
And after the flood trigger clear, the device will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Water Alarm (0x05) Event: 0x00
Sensor Binary Report (V2)
Sensor Type: Water (0x06) Sensor Value: 0x00
Tamper Report: (PAT02-A, PAT02-B, PAT02-C)
The tamper key pressed over 5 seconds. The device will into the alarm state.
In that state, if the tamper key be released, the device will unsolicited to
send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08) Sensor Value: 0xFF
Temperature Report: (PAT02-A, PAT02-B)
When the flood triggered or the temperature differential over 1 Fahrenheit (in
default), the device will unsolicited to send the “Sensor Multilevel Report”
to the nodes in the group 1.
Sensor Type: Temperature (0x01)
Note:
To disable send temperature report after the flood triggered, please setting
the configuration N0.5 bit5 to 1.
Temperature differential report
This function default is enabled, to disable this function by setting the
configuration NO.21 to 0.In the default, when the temperature is changed to
plus or minus one degree Fahrenheit (0.56 degree Celsius), the device will
report temperature information to the nodes in the group 1.The device will
measure the temperature in every 10 seconds. And if the temperature is over
140 degree Fahrenheit (60 degree Celsius), the device will always report in
each measurement.
Humidity Report: (PAT02-A, PAT02-B)
When the flood triggered or the humidity differential over 5 percent (in
default), the device will unsolicited to send the “Sensor Multilevel Report”
to the nodes in the group 1.
Sensor Type: Humidity (0x05)
Note:
To disable send humidity report after the flood triggered, please setting the
configuration N0.6 bit6 to 1.
Humidity differential report
This function default is enabled, to disable this function by setting the
configuration NO.23 to zero.Enable this functionality, the device will measure
the humidity in every 10 seconds. And if the humidity is changed to plus or
minus the value (setting by the configuration NO.23), the device will report
humidity information to the nodes in the group 1.
Timing Report:
Beside the event triggered could report message, the device also support the
timing unsolicited report of the status.
- Battery level report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 10.
- Low battery report: When the battery level is too low, every 30 minutes will report once.
- Temperature report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 13.
- Humidity report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 14.
- Flood state report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 15.
Notice:
The configuration NO. 10, 13, 14 and 15 could be setting to zero to disable
the auto report. And the configuration NO. 20 could change the tick interval,
the default value is 30, if setting to 1, that means the minimum auto report
interval will be one minute. And please notice if setting this value to zero,
that means disable all of the timing report except the low battery detection.
Power Up Procedure
Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue to
flash about 5 seconds. Please change to another new battery.
NWI
When the device power on, the device will check is it already adding to the
network? If doesn’t, it will auto start the NWI mode. The LED will flash in
every second and continue 30 seconds. Until timeout or the device is
successful to included by controller. The use can presses the tamper key 3
times to abort the NWI mode.PS: If the device already adding to the network,
the device will broadcast node information once.
Wake
When the device power on, the device will wake about 20 seconds. In this
duration, the controller can communicate with the device. Normally the device
is always sleeping to save the battery energy. Over The Air (OTA) Firmware
UpdateThe device support the Z-Wave firmware update via OTA. Let the
controller into the firmware update mode, and then press the tamper key once
to start the update. After finish the firmware download, the LED will start
flash in every 0.5 second. At that time, please don’t remove the battery,
otherwise it will cause the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the device.
Caution: After remove the battery, please wait about 30 seconds, and then re-
install the battery.
Security Network
The device support the security function. When the device included with a
security controller, the device will auto switch to the security mode. In the
security mode, the follow commands need using Security CC wrapped to
communicate, otherwise it will not response.
- COMMAND_CLASS_BATTERY
- COMMAND_CLASS_NOTIFICATION_V4
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_CONFIGURATION
- COMMAND_CLASS_SENSOR_BINARY_V2
- COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- COMMAND_CLASS_WAKE_UP_V2
Installation
- To mount the device on the wall, you can choose using the tape, or a screw.
- Using the screw to fix the flood detector.
Z-Wave Configuration Settings
- All of the configurations, the data size is 1.
- The configuration mark with star(*), means after the remove the setting still keeps, don’t reset to factory default. Unless the user executes the “RESET” procedure.
- The reserve bit or not supported bit is allowed any value, but no effect.
NO
.
| Name| Def.| Vali d| A| B| C| Description
---|---|---|---|---|---|---|---
1
| Basic Set OFF Level|
0
|
All
| 0| o| 0| Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2.
2
| Basic Set ON Level|
0xFF
|
All
| 0| o| 0| Setting the BASIC command value. When the flood trigger on(0xFF), send the BASIC CC to the group 2.
5
(*)
|
Operation Mode
| | All| 0| 33| 32| Operation mode. Using bit to control.
0| | 0| o| 0| Bit0 : Disable the Flood function.
0| | o| o| o| Bit1 : Reserve.
0| | o| o| o| Bit2 : Reserve.
0| | 0| 0| o| Bit3 : Setting the temperature scale. 0: Fahrenheit,
1:Celsius
0| | o| o| o| Bit4 : Reserve.
0
| | 0| o| o| Bit5 : Disable the temperature report after event triggered.
(1:Disable, 0:Enable)
0| | o| o| o| Bit6 : Reserve.
0| | o| o| o| Bit7 : Reserve.
6
(*)
| Mult- Sensor Function Switch| |
All
|
0
|
64
|
64
| Multisensor function switch. Using bit to control.
0| | o| o| o| Bit0 : Reserve.
0| | o| o| o| Bit1 : Reserve.
0| | o| o| o| Bit2 : Reserve.
0| | o| o| o| Bit3 : Reserve.
0| | o| o| o| Bit4 : Reserve.
NO
.
| Name| Def.| Vali d| A| B| C| Description
---|---|---|---|---|---|---|---
| | 0| | o| o| o| Bit5 : Reserve.
0| | 0| o| o| Bit6 : Disable the humidity report after event triggered.
(1:Disable, 0:Enable)
0| | o| o| o| Bit7 : Reserve.
7
(*)
|
Customer Function
| |
All
|
0
|
0
|
0
| Customer function switch, using bit control.
0| | o| o| o| Bit0 : Reserve.
0| | o| o| o| Bit1 : Reserve.
0| | o| o| o| Bit2 : Reserve.
0
| | 0| o| 0| Bit3 : Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
0
| | 0| 0| 0| Bit4 : Notification Type,
0: Using Notification Report. 1: Using Sensor Binary Report.
0| | 0| 0| 0| Bit5 : Disable Multi CC in auto report. (1:Disable, 0:Enable)
0
| | 0| o| 0| Bit6 : Disable to report battery state when the device triggered. (1:Disable, 0:Enable)
0
| |
o
|
o
|
o
| Bit7 : Reserve.
10| Auto Report Battery Time| 12| 0 ~
127
| 0| 0| 0| The interval time for auto report the battery level.
0 means turn off auto report.
The default value is 12. The tick time
NO
.
| Name| Def.| Vali d| A| B| C| Description
---|---|---|---|---|---|---|---
| | | | | | | can setting by the configuration No.20.
13
|
Auto Report Temperatur e Time
|
12
|
0 ~
127
|
0
|
0
|
o
| The interval time for auto report the temperature.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
14
|
Auto Report Humidity Time
|
12
|
0 ~
127
|
0
|
0
|
o
| The interval time for auto report the humidity.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
15
|
Auto Report Flood Time
|
12
|
0 ~
127
|
0
|
o
|
0
| The interval time for auto report the flood state.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
20
|
Auto Report Tick Interval
|
30
|
0 ~
0xFF
|
0
|
0
|
0
| The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.
Units of one minute.
Caution1 : Setting to 0 means turn off all auto report function.
Caution2 : The value is unsigned byte
21| Temperature Differential Report| 1| 0 ~
0x7F
| 0| 0| o| The temperature differential to report. 0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will detect every 10 seconds.
NO
.
| Name| Def.| Vali d| A| B| C| Description
---|---|---|---|---|---|---|---
| | | | | | | And when the temperature is over 140 degree Fahrenheit, it will
continue report.
23
|
Humidity Differential Report
|
5
|
0 ~
60
|
0
|
0
|
o
| The humidity differential to report. 0 means turn off this function.
The unit is percentage.
Enable this function the device will detect every 10 seconds.
| | | | | | |
Z-Wave Supported Command Class
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY
- COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2
- COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL
- COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD
- COMMAND_CLASS_SECURITY
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Warning
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new once, the retailer is legally obligated
to take back your old appliance for disposal at least for free of charge.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>