RoHS Infrared Thermometer User Guide

June 7, 2024
RoHS

Infrared Thermometer User Guide

RoHS Infrared Thermometer - thermometar

Model: K3 Pro

Introduction

RoHS Infrared Thermometer - Introduction

Specification

  1. Accuracy: ±0.2 degrees(35~42℃,place it in the operating environment for 30 minutes before use)
  2.  Alarm Function: abnormal automatic alarm, flash + sound alarm for about 10 seconds
  3. Measuring distance: 5cm~10cm automatic measurement
  4. Display: LCD display
  5. Transmission interface: USB Type C
  6. Adaptable power supply: 4 AA batteries (external power supply and internal power supply can be switched)
  7. Install method: nail hook, bracket fixing
  8. Environment temperature: 10℃~40℃ (recommended 15℃~35℃)
  9.  Measuring range: 0~50℃
  10.  Response time: 0.5s
  11.  Standby: 30s automatic standby during non-working hours
  12.  Input: DC 5V 500mA
  13. Weight:303g
  14.  Dimensions: 170X115X140mm
  15. Counting capacity: 9999 times

Display Description

RoHS Infrared Thermometer - Display Description

  1. Working mode: count mode, working mode, surface mode.
  2. Status indication: expression, USB connection status, volume, power.
  3. Measurement result: temperature status or count status.
  4. Temperature unit: Celsius or Fahrenheit.
  5. Setting item or historical record: M* indicates the historical record number indicates the setting item number.
  6. History Temp or Environment Temp.
  7. Environment temperature status.

State description

  1. Standby:
    The backlight is turned off and the temperature remains displayed. (Fig. 1)
    RoHS Infrared Thermometer - State description

  2. Insufficient power:
    The display indicates that the battery is empty and the icon flashes.(Fig. 2)
    RoHS Infrared Thermometer - Insufficient

  3. Normal temperature:
    Flashing green lights on both sides
    RoHS Infrared Thermometer - Normal

  4. Abnormal temperature:
    Flashing red lights on both sides
    RoHS Infrared Thermometer - Abnormal

  5. Out of range(in working mode)
    ‘Lo’: Ultra-low temperature than 35 degrees Celsius(Fig. 5)
    ‘HI’: Ultra-high temperature than 42 degrees Celsius(Fig. 6)
    RoHS Infrared Thermometer - Out of range

Operation Instruction

  1. Temperature measurement:
    Front of the thermometer, approach it within 5-10cm.(Fig. 7)
    RoHS Infrared Thermometer - measurement

  2. History temperature query:
    Press the left and right buttons to query the historical temperature, M** represents the current historical temperature.The device currently supports up to 30 historical temperatures.
    RoHS Infrared Thermometer - query

  3. Temperature unit setting:
    Press the SET button to F1, press the left and right buttons to switch between Celsius and Fahrenheit. C:Celsius F:Fahrenheit
    RoHS Infrared Thermometer - setting

  4. Mode setting:
    Press the SET button to F2, press the left and right buttons to switch the working mode.
    RoHS Infrared Thermometer - setting 2

  5. Alarm temperature setting:
    Press the SET button to F3, it is the alarm setting state of the working model. Press the left and right buttons to switch the alarm
    temperature between 37.0~38.0. The default is 37.3 ℃.
    Note: The alarm temperature is only valid in the working mode.
    RoHS Infrared Thermometer - setting 3

  6. Volume setting:
    Press the SET button to F4, it is the volume setting state. Press the left and right buttons to adjust the volume. The more parentheses
    behind the small speaker, the greater the volume, and the disappearance of the small speaker represents mute.
    RoHS Infrared Thermometer - setting 4

  7. Backlight setting:
    Press the SET button to F5, it is the backlight setting state. Press the left and right buttons to turn the backlight on or off.
    ON: turn on the backlight
    OFF: turn off the backlight
    RoHS Infrared Thermometer - setting 5

  8. Language setting:
    Press the SET button to F6, press the left and right buttons to switch the language of the voice broadcast.
    CH: Chinese EN: English
    RoHS Infrared Thermometer - setting 6

  9. Output signal setting:
    Press the SET button to F7, press the left and right buttons to switch the output signal type. S1 represents the switch mode and S2 represents the pulse mode.
    For more instructions about output signals.
    please refer to the output signal user guide.
    RoHS Infrared Thermometer - setting 7

  10. Battery installation:
    Open the battery cover and install the new battery correctly according to the battery polarity.
    RoHS Infrared Thermometer - Battery

  11. Install method: nail hook, bracket fixing
    RoHS Infrared Thermometer - Install method

Warnings

  1. It is the user’s responsibility to ensure the electromagnetic compatibility environment of the device so that the device can work normally.
  2. It is recommended to evaluate the electromagnetic environment before using the device.
  3. When changing the operating environment, the device must be left to stand for more than 30 minutes.
  4. Please measure the forehead to the thermometer.
  5. Please avoid direct sunlight when using outdoors.
  6. Keep away from air conditioners, fans, etc.
  7. Please use qualified, safety-certified batteries, unqualified batteries, or non-rechargeable batteries used may cause fire or explosion.

RoHS Infrared Thermometer - App