Product Specifications
Display method:
Common Screen display
Atmospheric pressure: 86Kpa – 106Kpa
Detection method for CO2 : Infrared (NDIR)
Sampling time: 1.5 seconds
Product Size: 96*33 MM
Detection temperature: -10°C to 50°C;
Relative humidity: 20% – 85%
Storage temperature: -10°C to 60°C;
Concentration unit for CO2:PPM
Power source: Lithium battery with 2000mAh capacity;
5V DC power charging via micro USB port
Product weight: 150g
Product Description
This product is an air quality monitor that detects Carbon dioxide (CO2), Temperature, and Humidity. it combines sensors’ real-time monitoring of Carbon dioxide (CO2), temperature, and humidity on its display.
Considerations
Please read the instructions carefully before using this device. Please let the device work short mins outdoors before use for the most accurate results . Please keep the manual handy for quick reference and troubleshooting.
Precautions
Avoid covering the air intake areas during use to avoid inaccurate
measurements.
Avoid the use of solvents to clean the product as residual fumes will skew air
quality readings.
Avoid water or other liquids near the product to avoid electrical damage.
Do not allow unauthorized modification or repair of this product.
Features:
-Common Screen display
-Test variables: Carbon dioxide (CO2), temperature, humidity
-Large 2000mAh capacity Lithium battery
-5V Micro USB charging
-Low battery warning
Instructions
1. Start-Up
When you long press the power button, the air quality monitor will boot up.
Product Key function description :
- Power button, long-Press to turn on/off, single-click to switch to CO2 alarm threshold setting.
- Left button, click to adjust
- Right button, click to adjust
- DC mini USB input port
Adjust LED brightness;
After turn on, the device auto access the interface which can show CO2 current
value, temperature, and humidity. In this state, press the left button to
increase LED brightness; Press right button to decrease LED brightness.(with
6 levels for brightness)
Set CO2 alarm threshold;
After turn on, the device auto access the interface which can show CO2
current value, temperature, and humidity. In this state, when you single-click
power button, the digits of CO2 would flash, then you can press left button
to increase CO2 alarm threshold, or press the right button to decrease CO2
alarm threshold.(CO2 alarm threshold can be set to 800ppm, 900ppm, 1000ppm,
1100ppm, 1200ppm,1300ppm, 1400ppm, 1500ppm, 1600ppm, 1700ppm, 1800ppm,
1900ppm, 2000ppm). After set well CO2 alarm threshold, press set button to
finish.
After you set CO2 alarm threshold well when the Current CO2 value is more than
the CO2 alarm threshold, the device would be a beep sound. (For example, you
set CO2 alarm threshold to 800ppm, once the current CO2 value is more than
800ppm, you would hear a beep sound)
Automatic calibration
During the first use, please Turn on the device and keep more than 24 hours,
the device will automatically calibrate. (Do not power off and restart halfway
when calibration)
2. About Charging
When a low battery icon is displayed, the device needs to be charged. Insert
the included or another compatible micro USB charging cable into the device.
Attach the other end to a USB DC charger (such as a smartphone charger) that
outputs DC 5V at >=1000mA. Fully charge for at least 2-3 hours before use.
Avoid charging with a USB computer port which only outputs 500mA.
3.Parameters :
CO2 technical indicators
Measuring range: 400-5000PPM
Sensor for CO2: Infrared ( NDIR)
Resolution: 1 PPM
Temperature and humidity technical indicators
Measuring range: -10-50 ° C
Humidity range: 20%-85% RH
Measurement accuracy: ±1 °C
Measurement accuracy: ±4% RH