Philio Flood Multisensor PAT02-A Manual

June 8, 2024
Philio

Philio

Flood Multisensor

SKU: PAT02-A

Quickstart

This is a
secure
Alarm Sensor
for
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

This product can be included and operated in any Z-Wave TM network with other Z-Wave TMcertified devices from other manufacturers and/or other applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 4 Used for returned events.
2 4 Used for Basic set event.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Basic Set OFF Level

Setting the BASIC command value.When the flood trigger off(0x00), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: 0

SettingDescription

-127 – 127 Setting the BASIC command value.

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127 The tick time can setting by the configuration No.20.

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127 The tick time can setting by the configuration No.20.

Parameter 14: Auto Report Humidity Time

The interval time for auto report the humidity.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127 The tick time can setting by the configuration No.20.

Parameter 15: Auto Report Flood Time

The interval time for auto report the flood state.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127 The tick time can setting by the configuration No.20.

Parameter 2: Basic Set ON Level

Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: -1

SettingDescription

-127 – 127 Setting the BASIC command value.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick.
Size: 1 Byte, Default Value: 30

SettingDescription

-127 – 127 Units of one minute.

Parameter 21: Temperature Differential Report

The temperature differential to report.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 127 The unit is Fahrenheit.

Parameter 23: Humidity Differential Report

The humidity differential to report.
Size: 1 Byte, Default Value: 5

SettingDescription

0 – 60 The unit is percentage.

Parameter 5: Operation Mode

Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0

SettingDescription

1 Disable the Flood function.
8 Setting the temperature scale.
32 Disable the temperature report after event triggered.

Parameter 6: Mult-Sensor Function Switch

Multisensor function switch. Using bit to control.
Size: 1 Byte, Default Value: 0

SettingDescription

64 Disable the humidity report after event triggered.

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 0

SettingDescription

8 Disable send out BASIC OFF after the flood event cleared.
64 Disable to report battery state when the device triggered.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.01:01.14
Z-Wave Version 6.81.03
Certification ID ZC10-20026862
Z-Wave Product Id 0x013C.0x0002.0x0078
Firmware Updatable Not Updatable
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Notification V8
  • Powerlevel
  • Security
  • Security 2
  • Sensor Multilevel V11
  • Supervision
  • Transport Service V2
  • Version V3
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals