ETEKCITY Infrared Thermometer User Manual
- June 7, 2024
- ETEKCITY
Table of Contents
Infrared Thermometer
Model No.: Lasergrip 1022
Questions or Concerns?
(855)-686-3835 • support@etekcity.com
Thank you for purchasing the Lasergrip 1022 Infrared Thermometer by Etekcity. This easy-to-use device lets you conveniently and accurately measure surface temperatures from a distance without the need of any direct contact. Should you have any questions or concerns, feel free to contact our helpful customer support team toll-free at 855.686.3835 or by email at support@etekcity.com.
WARNING: THIS DEVICE PRODUCES CLASS 2 LASER RADIATION. THE LASER LIGHT IS INVISIBLE TO THE HUMAN EYE. USE EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT LOOK INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM WITH OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO NOT DISASSEMBLE THE DEVICE.
IMPORTANT: Read all the instructions in this manual. Failure to comply with the instructions in this manual or use of the device, in ways other than the ones mentioned in this manual, may result in hazardous radiation exposure.
Safety Use & Care
-
DO NOT point the laser light at another person or animal.
-
DO NOT attempt to point laser-light at an aircraft.
-
Avoid direct/indirect eye contact with the laser beam. Laser radiation may cause damage to the eyes.
-
DO NOT view the beam with optical instruments.
-
In the vicinity of use, make any bystanders aware of the dangers of looking directly into the laser pointer.
-
DO NOT allow children to operate the device.
-
Use a 9V battery when replacing the battery within the device. Make sure to insert the battery in accordance with the correct polarities indicated.
-
ALWAYS remove the batteries when cleaning the device.
-
DO NOT use leaking batteries or dispose of old batteries in a fire.
-
Remove the battery for storage if the device is not being used for a prolonged period of time.
-
DO NOT disassemble the device or tamper with internal components.
Doing so will void any warranty. -
DO NOT touch the lens or wipe it using anything other than a soft cloth or cotton swab.
-
Keep the thermometer away from electromagnetic fields produced by objects such as arc welders and induction heaters.
-
DO NOT expose the thermometer to direct sources of heat for extended periods of time.
-
The thermometer measures surface temperature, not internal temperature. Do not use the Lasergrip as a reliable source to measure body temperatures.
Features & Specifications
- Laser-guided targeting for aiming precision
- The narrow distance-spot ratio for accurate results at greater distances
- Safely measure hazardous or inaccessible objects
- Standard 9V battery powers up to 12 hours of cumulative use
- Auto-off after 15 seconds of inactivity
- Measurement Range: -58°F ~ 1022°F (-50°C ~ 550°C)
- Accuracy: ±2% / ±2°C
- Resolution: 0.1°F /°C
- Maximum Output: < 1 mW
- Wavelength: 630 – 670 nm
- Distance-Spot Ratio: 12:1
- Response Time: < 500 ms
- Emissivity(Adjustable): 0.1-1.0
- Battery: DC 9V
Function Diagram
- LCD Display
- Display Backlight On / Off
- Laser Pointer / UP
- Unit (°C / °F) / DOWN
- Emissivity Adjustment / Max Temperatures
- Laser Hole
- IR Sensor
- Measurement Trigger
- Battery Compartment
Display Icon Key
- Low Battery
- Laser On
- Back-light On
- Continue Scanning
- °C / °F
- Temperature Result
- Max Temperature / Emissivity Result
- Max Temperature Sian
- Adjustable Emissivity Sign
Operation
Surface Temperature Measurement
NOTE: The Lasergrip cannot measure the temperature of objects behind glass.
Inaccuracy may also occur when exposed to steam, dust or any other
contaminants in the air.
- Once the battery is properly installed, press the measurement trigger to activate the device.
- Point the Lasergrip towards the surface of measurement.
- Press and hold the measurement trigger and the laser will activate for aiming guidance.
- Keep holding the trigger as you move the Lasergrip if you wish to live scan the surface area for temperature measurement.
- Once the laser is pointed to the desired point of measurement, release the trigger and the LCD display will lock the calculated temperature.
- Press the measurement trigger once again to make another measurement.
|
---|---
HOLD for continuous temperature reading| RELEASE to lock the temperature
result
NOTE: The Lasergrip LCD will display ‘OH’ when the measured temperature is above the measurable range and will display ‘OL’ when the measured temperature is below the measurable range.
Unit Conversion
To switch between units of temperature measurement, press the °C / °F button
at any time while the Lasergrip is on.
Laser Activation
To activate and deactivate the laser, press the laser pointer On /Off button
at any time while the Lasergrip is on.
Display Backlight Operation
To activate and deactivate the display backlight, press the display backlight
On / Off button at any time while the Lasergrip is on.
Emissivity Adjustment Mode
To adjust the emissivity value before measurement, press the emissivity
adjustment mode button, then use the UP and DOWN buttons to navigate to the
desired value. You may refer to the emissivity reference chart for correct
surface emissivity values.
Battery Replacement
A low battery icon will appear on the LCD display when the Lasergrip’s battery
power is running low. Immediately replace the battery when the icon appears.
1. Open the battery compartment and remove the used battery. Dispose the used
battery properly.
2. Connect a new DC 9V battery, making sure it’s under the correct polarity.
3. Insert the battery into the compartment and close the compartment lid,
making sure the wiring is not being pinched by the compartment lid.
Distance-Spot Ratio
The Lasergrip 1022 measures surface temperature on the basis of distance to
spot diameter ratio (D:S). As the distance between the thermometer and the
surface increases, the total surface area measured will also increase. With a
distance to spot ratio of 12:1 the surface area measured has a diameter of
roughly 1/12 the distance.
For the most accurate results, make sure the target has a surface area of
twice the corresponding spot diameter. Insufficient surface area will result
in inaccurate results. The recommended distance to hold the Lasergrip from the
surface of measurement is 14.17 in (36 cm). This creates a spot measurement
area of 1.18 inches (3 cm) in diameter.
Emissivity
The emissivity of a material is its efficiency in emitting thermal energy.
Non-reflective surfaces have a higher emissivity (closer to 1) than reflective
surfaces (closer to O). Inaccurate results may occur when measuring reflective
surfaces such as glass, polished wood, and granite.
To take accurate temperature measurements of reflective surfaces with low
emissivity, place a strip of black masking tape over the surface and allow for
it to adjust to the temperature of the surface for approximately 30 minutes.
Measure the surface, scanning the taped section, eliminating the issue of
inaccuracy ( See Emissivity Of Materials for details )
FCC Declaration
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received.
Including interference that may cause undesired operation.
Emissivity Of Materials
Material | Feature | Emissivity | Material | Feature | Emissivity |
---|---|---|---|---|---|
Aluminum | Oxidized | 3 | Human Skin | 0.98 | |
Polished | 0.02-0.04 | Graphite | Oxidized | 020-0.60 | |
Brass | Oxidized | 0.5 | Plastic | transparent | 0.95 |
Polished | 0.02-0.05 | Rubber | 0.95 | ||
Gold | 0.01-0.10 | Plastic Cement | 0.85-0.95 | ||
Iron | Oxidized | 0.7 | Concrete | 0.95 | |
Steel | Oxidized | 0.70-0.90 | Cement | 0.96 | |
Asbestos | 0.95 | Soil | 0.90-0.98 | ||
Plaster | 0.80-0.90 | Mortar | 0.89-0.91 | ||
Asphalt | 0.95 | Brick | 0.90-0.96 | ||
Rock | 0.7 | Marble | 0.94 | ||
Wood | 0.90-0.95 | Textile | 0.90 | ||
Charcoal | Powered | 0.96 | Paper | 0.95 | |
Carbon | 0.85 | Sand | 0.90 | ||
Lacquenvork | Lackluster | 0.97 | Clay | 0.92-0.96 | |
Carton Cement | 0.90 | Sand | 0.9 | ||
Soap Bubble | 0.75-0.80 | Glass | 0.85-0.92 | ||
Water | 0.93 | Textile | 0.95 | ||
Snow | 0.83-0.90 | Heated Food | 0.95 | ||
Ice | 0.96-0.98 | Plastic | 0.95 | ||
Frozen Foods | 0.95 | 11 | 0.94 | ||
Ceramics | 0.95 | Steel and iron | 0.80 | ||
Limestone | 0.98 | Wool | Natural | 0.94 | |
Paint | 0.93 | Lead | Oxidized | 0.5 |
The device certification information is labeled directly on the device. The sticker is located on the left side of the Lasergrip.
The device warning and aperture safety information are also labeled directly
on the device; the sticker is located on the right side of the Lasergrip.
Any updates to the product information (date of manufacturing and manufacturer
address) will be added as adhesive overlays.
Package Contents
1 x Lasergrip 1022
1 x 9V DC Battery
1 x User Manual
Warranty Information
Etekcity warrants all products to be of the highest quality in material,
craftsmanship, and service, effective from the date of purchase to the end of
the warranty period.
Etekcity will replace any product found to be defective due to manufacturer
flaws based on eligibility. Refunds are available within the first 30 days of
purchase. Refunds are only available to the original purchaser of the product.
This warranty extends only to personal use and does not extend to any product
that has been used for commercial, rental, or any other use in which the
product is not intended for. There are no warranties other than the warranties
expressly set forth with each product.
This warranty is non-transferrable. Etekcity is not responsible in any way for
any damages, losses, or inconveniences caused by equipment failure by user
negligence, abuse, or use noncompliant with the user manual or any additional
safety, use, or warnings included in the product packaging and manual.
This warranty does not apply to the following:
- Damage due to abuse, accident, alteration, misuse, tampering, or vandalism.
- Improper or inadequate maintenance.
- Damage in return transit.
- Unsupervised use by children under 18 years of age.
Etekcity and its subsidiaries assume no liability for damage caused by the use
of the product other than for its intended use or as instructed in the user
manual. Some states do not allow this exclusion or limitation of incidental or
consequential losses so the foregoing disclaimer may not apply to you. This
warranty gives you specific legal rights and you may also have other rights
which may vary from state to state.
ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF
MERCHANTABILITY, ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY.
Additional 1-Year Warranty
You can extend your 1-year warranty by an additional year. Log onto
www.etekcity.com/warranty and enter your order number (for example, from
Amazon or Houzz) to register your new product for the extended warranty.
If you are unable to provide the order number for your product, please type a
short note in the order number field along with the date you received your
product.
Defective Products & Returns
If your product proves defective within the specified warranty period, please
contact Customer Support via
support@etekcity.com with your order number. DO
NOT dispose of your product before contacting us. Once Customer Support has
approved your request, please return the unit with a copy of the invoice or
your order number.
Customer Support
If you encounter any issues or have any questions regarding your new product, please contact our helpful Customer Support Team. Your satisfaction is our goal!
Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806
USA
Support Hours
Mon – Fri 9:00 am – 5:00 pm PST/PDT
Toll Free: 855-686-3835
Email: support@etekcity.com
*Please have your order confirmation number ready before contacting
Customer Support.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>