levoit Classic 200 Ultrasonic Cool Mist Humidifier User Manual
- June 7, 2024
- Levoit
Table of Contents
USER MANUAL
Ultrasonic Cool Mist Humidifier
Model: Classic 200
Questions or Concerns?
Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT
at support@levoit.com or at
888-726-8520.
Thank you for purchasing the
CLASSIC 200 ULTRASONIC COOL MIST HUMIDIFIER BY LEVOIT.
If you have any questions or concerns, please reach out to us at
support@levoit.com.
We hope you enjoy your new humidifier!
Share the Levoit Love
Find @LevoitLifestyle on social media for
wellness + style inspiration.
We make every space mindful and chic.
@LevoitLifestyle
#LevoitLove • #LevoitLifestyle
Package Contents
1 x Ultrasonic Humidifier
3 x Aroma Pads (1 Pre-Installed)
1 x Cleaning Brush (Stored)
1 x User Manual
1 x Quick Start Guide
Specifications
Power Supply | AC 120V, 60Hz |
---|---|
Rated Power | 30W |
Water Tank Capacity | 1.05 gal / 4 L |
Max Run Time | Up to 40 hours |
Note: The humidifier will be able to run for a longer or shorter time
depending on the environmental temperature and humidity.
Noise Level| s 30dB
Effective Range| 285-376 ft2 / 24-35 m2
Dimensions| 14 x 8 x 6 in /
35.4 x 20.2 x15.2 cm
Weight| 3.5 lb /1.6 kg
SAFETY INFORMATION
To reduce the risk of fire, electric shock, or another injury, follow all instructions and safety guidelines.
General Safety
-
Only use the humidifier as described in this manual.
-
Place the humidifier and cord so that they will not be knocked over. Do not place near large pieces of furniture or in high traffic areas.
-
When not in use, turn the humidifier off and disconnect from power by removing the plug from the outlet.
-
Do not use the humidifier in wet environments.
-
Keep the humidifier out of reach from children.
-
Do not open the base or remove the water level sensor for self-servicing.
-
Always unplug your humidifier from the power outlet before cleaning your humidifier or detaching the water tank from the humidifier base.
-
Always make sure to place the humidifier on a flat, level surface before operation.
-
Only fill the water tank with clean water.
Never fill the water tank with any other liquids. -
Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
-
Do not place the humidifier directly on floors, carpets, or rugs.
-
Do not use other items as replacement parts for this product.
-
Do no t cover the nozzles while the humidifier is on. Doing so may damage the humidifier.
-
Remove the water tank from the base before moving the humidifier.
-
Do not immerse the humidifier base, power cord, or plug in water.
-
If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately (see page 15).
-
Not for commercial use. Household use only.
Plug and Cord
• Ensure that the plug fits properly into a polarized socket.
• Do not handle the power cord or plug with wet hands. Keep the plug and power
cord away from liquids.
• Your humidifier has a polarized plug (one prong is wider than the other),
which fits into a polarized outlet only one way. This is a safety feature to
reduce the risk of electric shock. If the plug does not fit, reverse the plug.
If it still does not fit, do not use the plugin that outlet. Do not
bypass this safety feature.
Caution: Risk of Leaks and Electric Shock
• Do not add essential oils, supplemental water treatment liquids, or water filters into the water tank or base. This will damage the humidifier and cause leaks. Only add essential oils to the aroma pad.
READ AND SAVE THESE INSTRUCTIONS
GETTING TO KNOW YOUR HUMIDIFIER
A. Nozzles
B. Nozzle Cap
C. Water Tank Handle
D. Mist Outlet
E. Water Tank
F. Cleaning Brush
G. Cleaning Brush Storage
H. Base| I. Control Button
J. Insulation Ring
K. Transducer
L. Float Housing
M. Float
N. Mist Tube
O. Water Tank Windows
P. Air Outlet| Q. Inner Chamber
R. Power Cord
S. Water Tank Cap
T. Silicone Sealing Ring
U. Water Valve
V. Noise Silencer
W. Aroma PadX. Aroma Box
---|---|---
GETTING STARTED
- Remove the nozzle cap from the water tank. Use the handle to lift the water tank from the base. [Figure 1.1]
- Flip the water tank over and twist open the water tank cap. [ Figure 1.2 ]
- Fill the water tank with at least 2 cups / 475 mL of cold or room temperature water. The maximum capacity is 1.05 gal / 4 L.
Note:
- We recommend using purified or distilled water to fill the tank.
- Do not fill the water tank with hot water.
- Only add water through the water tank cap. Do not add water through the nozzles, mist tube, or into the inner chamber.
- Do not lift the entire humidifier by the water tank handle.
- Do not add essential oils to the water tank or base. Only add essential oils onto the aroma pad. [Figure 1.3]
- Do not let water inside the air outlet.
- If water gets inside the air outlet, unplug the humidifier and pour out all water. Let the humidifier rest in a well-ventilated area for 24 hours. Do not use again until completely dry.
4. Replace the water tank cap and carefully place the water tank back onto
the base. Align the water tank cap with the inner chamber.
5. Place the nozzle cap back on top of the water tank.
USING YOUR HUMIDIFIER
General Operation
1.Place the humidifier on a level, elevated, and water-resistant surfaces,
such as a table or nightstand. Make sure the room is well-ventilated.
Note:
- Position the humidifier at least 12 in / 30 cm away from walls and appliances to prevent them from getting wet. [Figure 2.1]
- Do not place the humidifier directly on floors, carpets, or rugs.
- Direct the nozzles away from any furniture to prevent your furniture from getting wet.
2. Plug in the humidifier. will light up red for 2 seconds then turn off.
3. Tap to turn your humidifier on. Tap repeatedly to change the mist setting.
Control Button Color
Button Color | Function |
---|---|
Blue | Low mist setting is selected |
Orange | Medium mist setting is selected |
Purple | High mist setting is selected |
Blinking Red | No water in tank or tank not on base |
No Color | Humidifier is off |
Humidifier has been misting for more than 30 seconds
Note:
- Low mist is the default setting when the humidifier is first turned on.
- The power light will automatically turn off after 30 seconds while the humidifier is on. To check the current mist setting, tap once. Tap again to change the mist setting.
- Excessive humidity can cause health issues and mold growth. If the relative humidity in your room is over 60%, use the low mist setting or turn off the humidifier.
- If there is no water in the tank or the tank is removed, the transducer will turn off, the fan will turn off after 5 seconds, and will blink red before turning off.
Using the Aroma Box
Your humidifier can be used as an aroma diffuser.
- Turn off the humidifier.
- Push the aroma box at the back of the base and pull it out. [Figure 3.1]
- Put 2–3 drops of essential oil on the aroma pad.
- Replace the aroma box with the humidifier. Fill the water tank with water and place it back on the base (see Getting Started, page 7).
- Plugin and turn on the humidifier.
Preventing Water Leaks
The water tank on your humidifier may leak if not placed properly.
-
Make sure the silicone sealing ring around the water tank cap is secured at all times.
-
Twist and secure the cap tightly onto the water tank.
Note: A small gap between the cap and the tank is normal. -
Wipe off any excess water on the top and bottom of the base.
-
Do not shake the humidifier.
-
Make sure to place the humidifier on a flat, level surface.
KEEPING THINGS CLEAN
Caution:
- Always make sure the humidifier is unplugged before cleaning.
- The water in the inner chamber near the transducer may still be warm after turning off the humidifier. Use caution when pouring out the water.
- Do not use liquid detergents.
- We recommend using purified or distilled water instead of tap water to prevent hard water buildup.
- Do not submerge the base in water.
General Cleaning
You should clean your humidifier every 3 days. Change the water every day or every other day to avoid bacteria growth.
-
Unplug the humidifier.
-
Remove the nozzle cap from the water tank and rinse under clean, running water. Set it aside to air dry.
-
Remove the water tank from the base and pour out any water from the inner chamber. Fill the tank with 3 cups / 710 mL of distilled white vinegar. Replace the cap
and gently shake to coat all sides of the water tank. Allow it to sit for at least 1 hour.
Note: Do not allow water inside or around the air outlet to prevent damage to the humidifier. [Figure 4.1] -
Add 1 cup / 238 mL of distilled white vinegar to the inner chamber and soak for 1 hour.
-
Use the included cleaning brush to remove any scale buildup inside the water tank or inner chamber. [Figure 4.1]
-
Pour out the vinegar from the water tank and the inner chamber and thoroughly rinse with warm water.
Note: Do not submerge the base in water. -
Dry all parts with a clean, dry cloth. Make sure all parts of the humidifier are completely dry before reassembling or storing.
-
Do not use the humidifier immediately after disinfecting. This may be a health hazard.
Note: A 3% hydrogen peroxide solution may also be used instead of vinegar to disinfect the humidifier. Do not mix hydrogen peroxide and vinegar.
Cleaning the Aroma Pad
- Press the aroma box to release it from the base, and pull it out.
- Remove the aroma pad and rinse under warm, running water.
- Dry with a clean cloth and place it back into the aroma box.
Note: Do not pour liquid cleaners or detergents into the aroma pad or box.
Cleaning the Noise Silencer
- Press the release tab and gently pull away from the humidifier. [Figure 5.1]
- Rinse under clean, running water.
- Dry with a clean, dry cloth before replacing it.
Deep Cleaning the Humidifier
Deep clean the water tank every 2 weeks and before and after storing the
humidifier for a long period of time. You should also disinfect if there is
any mold buildup inside
the water tank or inner chamber.
Note: Only use vinegar and water too deep clean your humidifier.
-
Fill the water tank with 1 cup / 238 mL of vinegar along with 1 gal / 3.8 L of water.
-
Place the humidifier outdoors and allow it to run for 1 hour.
-
Pour out the mixture and refill with water. Then, run the humidifier for another hour outdoors.
-
Rinse the water tank and inner chamber thoroughly under clean, running water.
Note: Do not submerge the base in water. -
f storing, allow the water tank and base to completely air dry before reassembling.
TROUBLESHOOTING
Problem | Possible Solution |
---|---|
No mist comes out of the nozzles. | Plugin the humidifier and turn it on. |
Add at least 2 cups / 475 mL of purified or distilled water to the water tank.
Clean the humidifier (see Keeping Things Clean, page 10).
Water may be in the air outlet Take the water tank off of the base and allow
the outlet to fully air dry before using again.
Only a small amount of mist comes out of the nozzles.| Clean
the humidifier, especially the nozzles, air outlet, and transducer (see
Keeping Things Clean, page 10).
The humidifier runs out of water too quickly.| The humidifier uses
up water based on the environmental temperature and humidity. If your
environment is cold and/or dry, the humidifier will run out of water faster.
Humidifier produces an unusual smell.| If the humidifier is new, remove
the water cap, and place the water tank in a cool, dry place for 12 hours.
If essential oils were diffused on the aroma pad, rinse the pad under clean
water, and allow it to dry.
Clean the humidifier (see Keeping Things Clean, page 10).
A humidifier makes a loud or unusual noise| Make sure the water tank is
properly in place (see GettingStarted, page 7).
---|---
Place humidifier on a flat, level surface.
Add at least 2 cups / 475 mL of purified or distilled water into the water
tank.
The humidifier may be malfunctioning. Stop using the humidifier and contact
Customer Support (see page 15).
Mist comes out from the base.| Make sure the water tank is properly in place
(see GettingStarted, page 7).
White dust appears around the humidifier.| We recommend using purified or
distilled water to fill the humidifier. Avoid using water with high mineral
content.
Clean the humidifier (see Keeping Things Clean, page 10).
Water visibly leaks from the humidifier.| Stop using the humidifier and see
Preventing Water Leaks (page 9) before using it again. If the humidifier
continues leaking, contact Customer Support (see page 15).
---|---
Make sure the silicone sealing ring around the water tank cap is secure.
A puddle of water forms around the humidifier.| Run the humidifier on a lower
mist setting.
Open a window to ensure proper airflow for your humidifier, or move the
humidifier to a more well-ventilated room.
Make sure the water tank is properly in place (see Getting Started , page
7).
Make sure the silicone sealing ring around the water tank cap is secure.
When replacing the water tank, wipe off excess water from the water tank and
base.
Stop using the humidifier and see Preventing Water Leaks (page
9) before using again. If the humidifier still leaks, contact
Customer Support (see page 15).
Mold grows inside the humidifier.| Clean the water tank and inner chamber
regularly (see Keeping Things Clean, page 10).
If your problem is not listed , please contact Customer Suppor t (see page 15).
WARRANTY INFORMATION
Product | Ultrasonic Cool Mist Humidifier |
---|---|
Model | Classic 200 |
Default Warranty Period | 1 year |
For your own reference, we strongly recommend that you record your order ID and date of purchase.
Terms & Policy
Provost Corporation warrants all products to be of the highest quality in
material, craftsmanship, and service, effective from the date of purchase to
the end of the warranty period.
Provost Corporation will replace any product found to be defective due to
manufacturer flaws based on eligibility. Refunds are available within the
first 30 days of purchase. Refunds are only available to the original
purchaser of the product. This warranty extends only to personal use and does
not extend to any product that has been used for commercial, rental, or any
other use in which the product is not intended for. There are no warranties
other than the warranties expressly set forth with each product.
This warranty is non-transferrable. Provost Corporation is not responsible in
any way for any damages, losses, or inconveniences caused by equipment failure
by user negligence, abuse, or use noncompliant with the user manual or any
additional safety, use, or warnings included in the product packaging and
manual.
This warranty does not apply to the following:
- Damage due to abuse, accident, alteration, misuse, tampering, or vandalism.
- Improper or inadequate maintenance.
- Damage in return transit.
- Unsupervised use by children under 18 years of age.
Provost Corporation and its subsidiaries assume no liability for damage caused
by the use of the product other than for its intended use or as instructed in
the user manual. Some states do not allow this exclusion or limitation of
incidental or consequential losses so the foregoing disclaimer may not apply
to you. This warranty gives you specific legal rights and you may also have
other rights which may vary from state to state.
ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF
MERCHANTABILITY, ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY.
Additional 1-Year Warranty
You can extend your 1-year warranty by an additional year. Log onto
www.levoit.com/warranty to register your new
product for the extended warranty.
Please fill out all required fields and include your order ID, place of
purchase, and purchase date, if applicable.
Defective Products & Returns
If your product proves defective within the specified warranty period, please
contact Customer Support via support@levoit.com
with your order ID. Do not dispose of your product before contacting us.
Once Customer Support has approved your request, please return the unit with a
copy of the invoice or your order ID.
CUSTOMER SUPPORT
If you encounter any issues or have any questions regarding your new product,
feel free to contact our helpful Customer Support Team.
Customer Support
Provost Corporation
1202 N. Miller St., Suite A
Anaheim, CA 92806
Email : support@levoit.com
Toll-Free: 888-726-8520
Support Hours
Mon–Fri, 9:00 am–5:00 pm PST/PDT
*Please have your order invoice and order ID ready before contacting Customer Support.
levoit.com
Connect with us @LevoitLifestyle
AU0719MC-M1.1_0719Classic200
Documents / Resources
|
levoit Classic 200 Ultrasonic Cool Mist
Humidifier
[pdf] User Manual
Ultrasonic Cool Mist Humidifier, Classic 200
---|---
|
levoit CLASSIC 200 Ultrasonic Cool Mist
Humidifier
[pdf] Instruction Manual
CLASSIC 200 Ultrasonic Cool Mist Humidifier, CLASSIC 200, Ultrasonic Cool Mist
Humidifier, Cool Mist Humidifier, Mist Humidifier, Humidifier
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>