amazonbasics B07TTGZ8NZ Professional Binocular Stereo Zoom Microscope User Manual

June 7, 2024
AmazonBasics

amazonbasics - Logo

amazonbasics B07TTGZ8NZ Professional Binocular - Cover

Professional Binocular Stereo Zoom Microscope
B07TTGZ8NZ

amazonbasics B07TTGZ8NZ Professional
Binocular - Overview 2

amazonbasics B07TTGZ8NZ Professional Binocular - Overview
3amazonbasics B07TTGZ8NZ Professional
Binocular - Overview 4amazonbasics
B07TTGZ8NZ Professional Binocular - Overview 5

Parts Description

An Eyepiece cover x2 H Base O Power switch
B Diopter adjustment I Magnification power adjustment knob P 10x eyepiece x2
C Adjustable eyepiece housing J Height adjustment knob Q Eye cup x2
D Head K Focus knob R Dust cover
E Objective L LED incident light lamp S Adapter
F Stage clips M Power socket
G Black/white stage plate N Brightness adjustment wheel

IMPORTANT SAFETY INSTRUCTIONS

****Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included.

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following:
It is prohibited to disassemble the machine.
Risk of serious injury! Dyes are harmful by inhalation, harmful in contact with skin, harmful if swallowed.
Methylene Blue Dye: Avoid eye and skin contact. Causes serious eye irritation. Do not swallow. Do not inhale.

First aid in case of eye contact: Immediately flush eyes with excess water for 15 minutes, lifting lower and upper eyelids occasionally. Remove contact lenses if wearing any. Get medical attention if irritation develops.
First aid in case of skin contact: Immediately flush skin with excess water for 15 minutes while removing contaminated clothing. Get medical attention if irritation develops.
First aid in case of ingestion: Do not induce vomiting without medical advice. Consult a physician if necessary.
NOTICE Methylene Blue dye has been classified by the International Agency for Research on Cancer (IARC) as Group 3: Not classifiable as carcinogenic to humans.
NOTICE Use the product within the correct ambient conditions to avoid mildewing and damage.

  • Keep the work area clean, clear and away from any food storage. Prepare the slides in a well-lit area and close to a water supply. Use a solid table with a heat-resistant top.

  • Do not allow dyes to come into contact with any part of the body particularly mouth and eyes.

  • Do not eat, drink or smoke in the work area.

  • Clean all the accessories and the work area after each use.
    Wash hands thoroughly after handling and carrying out experiments.

  • A separate tin or bucket should be used for the disposal of specimen samples and dyes. Any wasted solution should be poured directly down a drain, but never into a sink basin.

  • Dispose of used specimen samples household trash immediately after use.

  • Do not discard any equipment into the fire to avoid violent combustion or explosion.

  • If the product has to be moved, carry with one hand holding the product at the arm and another hand supporting it at the base.

  • Examine the set regularly for potentially unsafe conditions, such as damaged housing, or parts. In the event of such damage, the set should not be used until it is properly repaired.

  • Store the set in its original packaging out of reach of children and animals.

  • Do not look directly at lighted lamp.

  • The light source of this lamp is not replaceable; when the light source reaches its end of life the whole lamp shall be replaced.

  • Use only the power supply model MKS-1201000 included for the light assembly.

SAVE THESE INSTRUCTIONS

**Symbols Explanation

**

| This product is classified as protection class II. This means the product is equipped with reinforced or double insulation between the mains supply circuit and the output voltage or the casing. Therefore it does not require a safety connection to electrical earth (ground).
---|---
| This product is for indoor use only.
| Direct current (DC).
| Alternating current (AC).
| Health advice for emergencies.
| Wash hands before and after experiments.
| Safety warning. Improper use of the product could result in injury or death.

Intended Use

  • This product is for private use, homeschooling, school applications and teaching demonstrations. It is not for commercial use.
  • This product is intended to be used in dry indoor areas only. · No liability will be accepted for damages resulting from improper use or non-compliance with these instructions.

Before First Use

  • Check the product for transport damages.

Risk of suffocation! Keep any packaging materials away from children ­ these materials are a potential source of danger, e.g. suffocation.

Assembly

amazonbasics B07TTGZ8NZ Professional Binocular -
Assemble1

  • Place the head (D) onto the top ring of the base (H), fasten the screw on the side to secure the head (D).
  • Remove the cover of the objective (E).

Light assembly

  • Fasten the screws of the LED incident light lamp (L) on to the objective (E).
  • Connect the adapter (S) 100 – 240 V~, 50/60 Hz; 12 V , 1000 mA, to a power outlet and the other end to the power socket (H) of the LED lamp (L).
  • Find the appropriate brightness of the LED lamp (L).
    NOTICE The bulbs of the LED incident light lamp (L) are irreplaceable. The LED lamp (L) should be discarded when it has reached its end of life.

Operation

Switching on/off

  • Flip the power switch (O) to “I” to turn on.
  • After use, flip the power switch (O) to “O” to turn off.

Calculating magnification power
Total magnification power is calculated by multiplying the magnification power of the eyepiece and the objective lens at a working distance of 0.4″ (100 mm).

Eyepiece magnification power| Objective lens magnification power| Total magnification power| Field of view
---|---|---|---
10x (P)| 0.7x (E)| 7x| 1.1″ (28.6 mm)
4.5x (E)| 45x| 0.17″ (4.4 mm)

Observing through the microscope

  • Use the black side of the black/white stage plate (G) for light-colored specimens and the white side for dark-colored specimens.
    amazonbasics B07TTGZ8NZ Professional Binocular -
Operation

  • Place the eyepieces (P) into the adjustable eyepiece housing (C).
    NOTICE To secure the eyepieces (P), tighten the screw on the side of the diopter adjustment (B) to lock the eyepieces (P) in place.

  • Attach the eye cups (Q) onto the eyepieces (P). NOTICE For users wearing eyeglasses, the eyecups (Q) are not needed during observation.

  • Rotate the magnification adjustment knob (I) to the lowest magnification power setting.
    NOTICE Start with the lowest magnification power every time a new specimen is placed on a stage plate (G). Most observations are made at low magnification power.
    amazonbasics B07TTGZ8NZ Professional Binocular - Operation
2

NOTICE The stage area of this microscope is wide enough to hold wide containers or petri dishes to hold the specimen.

  • Place the container, slide or petri-dish holding the specimen (not included) onto the stage plate (G). Secure the specimen with the stage clips (F) if needed.

  • Turn the height adjustment knob (J) to adjust the height of the head (D) to an estimated viewing distance.

  • Look into the eyepieces (P) and adjust the brightness of the LED lamp (L) using the brightness adjustment wheel (N).

  • Look into the left eyepiece (P), rotate the focus knob (K) and the diopter adjustment (B) slowly until the image is clear. Adjust the position of the specimen if needed.

  • Look into the right eyepiece (P), rotate the diopter adjustment (B) until the image is clear.
    amazonbasics B07TTGZ8NZ Professional Binocular - Operation
3

  • Look into both eyepieces (P), move around the adjustable eyepiece housing (C) until the two images merge into one.

  • Rotate the magnification adjustment knob (I) to the higher magnification power. Re-adjust the focus using the focus knob (K) and the diopter adjustment (B) if needed.
    NOTICE Never turn adversely to left and right directions the knobs, eyepieces at the same time, otherwise the microscope will be damaged.

  • After using the microscope, remove the specimen from the stage plate (G).

  • Switch off the LED lamp (L) and disconnect the adapter (S) from the power outlet.

  • Clean the work area and dispose of the used specimens.

Cleaning and Maintenance

  Risk of damage! During cleaning do not immerse the product in water or other liquids. Never hold the product under running water.
Cleaning

  • To clean the lenses (E, P), only use lens cleaning tissues. Do not use cloth, paper or hands.
  • To clean the product, wipe with a soft, slightly moist cloth.
  • Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product.

Maintenance

  • After each use, place the dust cover (R) on the microscope. Place the accessories back into their respective plastic bags to prevent dust from collecting.
  • Slight greasing or putting oil may be needed for the mechanical moving parts. Apply the appropriate oil discreetly.
  • The product ought to be placed in a dry and clean place. Do not expose the microscope in the sun directly.
  • Never subject the product to high temperature and violent vibration.

FCC ­ Supplier’s Declaration of Conformity

Unique Identifier| B07TTGZ8NZ-Professional Binocular
Stereo Zoom Microscope
---|---
Responsible Party| Amazon.com Services, Inc
U.S. Contact Information| 410 Terry Ave N.
Seattle, WA
98109, United States
Telephone Number| 206-266-1000

FCC Compliance Statement

  1. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
    (1) this device may not cause harmful interference, and
    (2) this device must accept any interference received, including interference that may cause undesired operation.

  2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the quipment.

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio / TV technician for help.

Canada IC Notice

  • This Class B digital apparatus complies with Canadian CAN ICES-3(B) / NMB-3(B) standard.

Specifications

LED assembly

Adapter input:| 100 – 240 V~, 50/60 Hz, 0.3 A
Adapter output:| 12 V , 1000 mA
Model:| MKS-1201000
LED lamp:| 64-Bulb LED ring light
Microscope
Magnification power range:| 7x to 45x
Working temperature:| -40 to 158 °F (-40 to 70 °C)
R.H. range:| 10 to 80 %
Net weight:| approx. 26.4 lbs (12 kg)
Dimensions (W x H x D):| approx. 7.9 x 14.5 x 12.6″

Feedback and Help

Love it? Hate it? Let us know with a customer review.

AmazonBasics is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the product.
amazon.com/review/review-your-purchases#
amazon.com/gp/help/customer/contact-us

amazonbasics - logo 2amazon.com/AmazonBasics

MADE IN CHINA
V01-08/19

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AmazonBasics User Manuals

Related Manuals