APPLICATION
The V2080 Design TRVs have a high-class appearance to match design radiators.
Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply of radiators or heat exchangers. Together with a radiator thermostat, they control the room temperature by regulating the flow of hot water into the radiator or heat exchanger. The temperature of different rooms is controlled individually, and energy is saved.
TRV bodies of this type are suitable for
- Honeywell Home radiator thermostats with M30 x 1.5 connection and from an optical aspect especially the Thera-200 Design series
Overview
-
Angle
-
Straight
-
Double angle right
-
Double angle left
SPECIAL FEATURES
- Perfect finishing with high quality surface in chrome, white (RAL 9016) or matt black (RAL 9004)
- Available in angled, straight and double angle pattern
- Including a chromed tail piece with integrated O-ring
- Presettable by stroke limitation
- For 2-pipe systems
- Standard M30 x 1.5 thermostat connection
- Connections for all types of pipework available
- Quiet operation
TECHNICAL DATA
Medium: | Water or glycol-water mixture, according to VDI 2035 |
---|---|
pH-value: | 8 – 9.5 |
Operating temperature: | 2 – 100°C |
Operating pressure: | PN10 |
Max. differential pressure: | 100 kPa (1 bar) 20 kPa (0.2 bar) |
recommended for quiet operation
Max. nominal flow at 10 kPa (EN 215):| 300 l/h ±10%
Body-head connection:| M30 x 1.5
Closing dimension:| 11.9 mm
Stroke:| 2.5 mm
CONSTRUCTION
Overview
No.
|
Components
|
Materials
---|---|---
1
| Valve body| Brass, EPDM 70 O-Rings
2
| Radiator connection tailpiece with coupling nut and O-Ring seals
3
| Insert cartridge with O-Ring seals for the axis and the body
4
| Plunger support washer
5
| Plunger seal| EPDM 70
6
| Spindle| Stainless steel
7
| Stroke-limiting dial, with O-Ring seals for the axis and the body| PA6, EPDM 70 O-Rings
8
| Protection cap| PP
| Not depicted components:
| Restoring spring with retaining rivet| Stainless steel and copper river
METHOD OF OPERATION
Thermostatic radiator valves enable individual control of room temperature and thus save energy. The TRV body is controlled by the radiator thermostat. Air from the room passing over the sensor of the radiator thermostat causes the sensor to expand when the temperature rises. The sensor acts onto the valve spindle and this causes the TRV body to close. When the temperature falls the sensor contracts and the springloaded valve spindle is opened. The TRV opens in proportion to the temperature of the sensor. Only the amount of water required to maintain the room temperature set on the radiator thermostat can flow into the radiator.
TRANSPORTATION AND STORAGE
Keep parts in their original packaging and unpack them shortly before use.
The following parameters apply during transportation and storage:
Parameter|
Value
---|---
Environment:|
clean, dry and dust free
Min. ambient temperature:|
0 °C
Max. ambient temperature:|
50 °C
Max. ambient relative humidity:|
75 % *
- non condensing
INSTALLATION GUIDELINES
Setup requirements
- To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035
- Additives have to be suitable for EPDM sealings
- System has to be flushed thoroughly before initial operation with all valves fully open
- Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell Home
- Please contact us if you should have any special requirements or needs
Installation Example
Fig. 1 Angle version
Fig. 2 Straight version
Fig. 3 Double angle version
TECHNICAL CHARACTERISTICS
Pressure drop characteristics
Presetting
| 1| 2| 3| 4| 5| 6| 7|
8
---|---|---|---|---|---|---|---|---
k v -value, 2K p-band
| –| 0.063| 0.32| 0.63| 0.95| 0.95| 0.95| 0.95
k vs| –| 0.063| 0.32| 0.65| 1.2| 1.5| 1.7|
1.9
Note: Setting 1 is not recommended.
Tab. 1 Temperature settings with Honeywell Home thermostatic heads
P-Band
| **| 1| 2| 3| 4| 5| 6
---|---|---|---|---|---|---|---
k v -value**| 5| 10| 13| 13| 19| 22|
25
DIMENSIONS
-
Fig. 4. Angle -
Fig. 5. Straight -
Fig. 6. Double angle
Body type
| Colour| DN| I| L| h| H| G| F|
OS-No.
---|---|---|---|---|---|---|---|---|---
E – Angled (Fig. 4)
| white| 15| –| 55| 25| 51| G 1/2″| 24×19| V2081ESL15A
chrome
| 15| –| 55| 25| 51| G 1/2″| 24×19| V2082ESL15A
matt black| 15| –| 55| 25| 51| G 1/2″| 24×19|
V2083ESL15A
D – Straight (Fig. 5)
| white| 15| 26| 81| 28| 44| G 1/2″| 24×19|
V2081DSL15A
chrome
| 15| 26| 55| 29| 45| G 1/2″| 24×19| V2082DSL15A
matt black| 15| 26| 55| 29| 45| G 1/2″| 24×19|
V2083DSL15A
R – Double Angle (Corner) Right (Fig. 6)
|
white
| 15| 26| 55| 29| 45| G 1/2″| 24×19| V2081RLS15A
chrome| 15| 26| 55| 29| 45| G 1/2″| 24×19|
V2082RLS15A
matt black
| 15| 26| 55| 29| 45| G 1/2″| 24×19| V2083RLS15A
L – Double Angle (Corner) Left (Fig. 6)| white| 15| 26| 55| 29| 45| G 1/2″|
24×19|
V2081LSL15A
chrome
|
15
| 26| 55| 29| 45| G 1/2″| 24×19| V2082LSL15A
matt black| 15| 26| 55| 29| 45| G 1/2″| 24×19|
V2083LSL15A
Note: All dimensions in mm unless stated otherwise.
Note: 24X19 is an M24 thread with 19 turns per inch.
ORDERING INFORMATION
Accessories
|
Description
|
Dimension
|
Part No.
---|---|---|---
| FEM24C| Pipe
Connections
Design compression fitting for COPPER pipe. Consisting of compression nut and compression ring. For valves with external thread M24x19. (1 pack)
| | 12 mm| FEM24C12
14 mm| FEM24C14
15 mm| FEM24C15
16 mm| FEM24C16
| FEM24P| Pipe
Connections
Design compression fitting for PEX pipe. Consisting of compression nut, compression ring and reinforcing insert. For valves with external thread M24x19. (1 pack)
| | 12 x 1.1 mm| FEM24P12X1.1
14 x 2 mm| FEM24P14X2
16 x 1.5 mm| FEM24P16X1.5
16 x 2 mm| FEM24P16X2
18 x 2 mm| FEM24P18X2
| FEM24M| Pipe Connections
Design compression fitting for MULTILAYER pipe. Consisting of compression nut, compression ring and reinforcing insert. For valves with external thread M24x19. (1 pack)
| | 12 x 2 mm| FEM24M14X2.1
16 x 2 mm| FEM24M16X2
18 x 2 mm| FEM24M18X2
20 x 2 mm| FEM24M20X2
| VA2201D| Rosette white
(RAL9016) for wall covering
| | Ø 40 x 12 mm| VA2201D012
Ø 40 x 14 mm| VA2201D014
Ø 40 x 15 mm| VA2201D015
Ø 40 x 16 mm| VA2201D016
Ø 40 x 18 mm| VA2201D018
Ø 40 x 20 mm| VA2201D020
| VA2201E| Rosette chrome
for wall covering
| | Ø 40 x 12 mm| VA2201D012
Ø 40 x 14 mm| VA2201D014
Ø 40 x 15 mm| VA2201D015
Ø 40 x 16 mm| VA2201D016
Ø 40 x 18 mm| VA2201D018
Ø 40 x 20 mm| VA2201D020
| VA2200C| Manual design
handwheel
| White (RAL9016)| | VA2200C001
Chrome| VA2200C002
| T4xxx| Thera-200 Design
radiator thermostat
| white/chrome| | T4021
chrome/chrome| T4221
black/chrome| T4321
For more information
homecomfort.resideo.com/europe
Ademco 1 GmbH
Hardhofweg 40
74821 MOSBACH
GERMANY
Phone: +49 6261 810
Fax: +49 6261 81309
Manufactured for and on behalf of the Pittway Sàrl, La Pièce 4, 1180 Rolle, Switzerland by its Authorised Representative Ademco 1 GmbH EN0H-2108GE25 R0121 Subject to change
© 2021 Pittway Sàrl. All rights reserved.
This document contains proprietary information of Pittway Sàrl and its
affiliated companies and is protected by copyright and other international
laws. Reproduction or improper use without specific written authorisation of
Pittway Sàrl is strictly forbidden. The Honeywell Home trademark is used under
license from Honeywell International Inc.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>