Z Wave SR-ZV9001K12-DIM-Z4 Z-Wave Dim Remote Control Instructions

June 7, 2024
Z-Wave

Z Wave logo

Z-Wave Protocol Implementation Conformance Statement

Z-Wave Dim Remote Control

General Information

Product Identifier: SR-ZV9001K12-DIM-Z4
Brand Name: Sunricher
Product Version: HW: 1 FW: 1.26
Z-Wave Certification #: ZC10-20066927

Product Features

Battery Quantity 2
Battery Type CR2450
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Central Scene

Z-Wave Product Information

Supports Z-Wave Beaming Technology? Supports Z-Wave Network Security? No
Supports Z-Wave AES-128 Security S0? Supports Security S2? Yes
SmartStart Compatible? Yes
Supports Z-Wave Beaming Technology? Supports Z-Wave Network Security? Yes: S2

Unauthenticated
Supports Z-Wave AES-128 Security S0? Supports Security S2?| No

Z-Wave Technical Information

Z-Wave Frequency: CEPT (Europe)
Z-Wave Product ID: 0xb302
Z-Wave Product Type: 0x0300
Z-Wave Hardware Platform: ZM5101
Z-Wave Development Kit Version: 6.71.03
Z-Wave Library Type: Enhanced 232 Slave
Z-Wave Device Type / Role Type: Wall Controller / Portable Slave

Association Group Information

Group # / Max Description
Nodes

1 / 5

| 1. Send Command Class “Device Reset Locally Notification V1” to associated devices of this group to report factory reset information when the factory reset the remote control. 2. When remote control battery power value changes, send Command Class “Battery Report V1” to associated devices of this group to report power value information. 3. Short press or press and hold down any button to send scene activation command to the associated devices of this group using Command Class “Central Scene Notification V3”
---|---
2 / 5

| 1. Short press the I1 / O1 button of Group 2 to send the ON/OFF command to associated devices of this group using Command Class “Basic Set V2”. 2. Press and hold down I1 / O1 button of Group 2 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”. 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20.
3 / 5

| 1. Short press I2 / O2 button of Group 3 to send the ON/OFF command to associated devices of this group using Command Class “Basic Set V2”. 2. Press and hold down the I2 / O2 button of Group 3 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”. 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20.
4 / 5| 1. Short press the I3 / O3 button of Group 4 to send the ON/OFF command to associated devices of this group using Command Class “Basic Set V2”. 2. Press and hold down I3 / O3 button of Group 4 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”. 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20.
5 / 5| 1. Short press I4 / O4 button of Group 5 to send the ON/OFF command to associated devices of this group using Command Class “Basic Set V2”. 2. Press and hold down I4 / O4 button of Group 5 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”. 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20.

Supported Command Classes (17):

Association Group Info Association V2
Battery Central Scene V3
Configuration Device Reset Locally
Firmware Update Meta-Data V4 Manufacturer Specific V2
Multi-Channel Association V3 Powerlevel
Security S0 Security S2
Supervision Transport Service V2
Version V2 Wake Up V2

Controlled Command Classes (2): Basic
Switch Multilevel V4
Copyright © 2012-2021 Z-Wave Alliance. All Rights Reserved. All Logos property of respective rights’ holders, no claim intended.
Generated @ August 20, 2021

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)