Table of Contents
- Welcome Guide
- Additional Battery Warnings
- Symbols
- Before First Use
- Operation
- Switching on/off
- Indicators patterns
- Automatic voltage regulation
- Sensitivity adjustment
- Connecting to a computer
- Replacing the battery
- Cleaning and Maintenance
- System Functional Block Diagram
- Troubleshooting
- FCC – Supplier’s Declaration of Conformity
- Canada IC Notice
- Specifications
- Feedback and Help
- Documents / Resources
Line-Interactive UPS 1000VA 550 Watt, 9 Outlets
UPS de Línea Interactiva, 1000 VA, 550 Watts, 9 Tomas
Onduleur Line-Interactive 1 000 VA 550 Watts, 9 Sorties
B07RRYB3RJ K01-1198009-01
Welcome Guide
Contents:
Before getting started, ensure the package contains the following
components:
Power button
| G USB type B socket
---|---
MUTE button| H WIRING FAULT indicator
ONLINE indicator| I Battery backup & surge protection outlets
AVR indicator| J Power cord with plug
ON BATTERY indicator| K Surge protection outlets
OVERLOAD indicator| L RESET button/circuit breaker
SAVE THESE INSTRUCTIONS
Read these instructions carefully and retain them for future use. If this
product is passed to a third party, then these instructions must be included.
When using electrical appliances, basic safety precautions should always be
followed to reduce the risk of fire, electric shock, and/or injury to persons
including the following:
CAUTION Risk of Energy Hazard! 12 V, 9 Ampere-hour battery. Before
replacing batteries, remove conductive jewelry such as chains, wristwatches,
and rings. High energy through conductive materials could cause severe burns.
CAUTION Risk of explosion! Do not dispose of batteries in fire. The
batteries may explode.
CAUTION Risk of injury! Do not open or mutilate batteries. Released
material is harmful to the skin and eyes. It may be toxic.
CAUTION Risk of electric shock! A battery can present a risk of
electrical shock and high short-circuit current. The following precautions
should be observed when working on batteries:
- Remove watches, rings, or other metal
- Use tools with insulated
- Wear rubber gloves and
- Do not lay tools or metal parts on top of
- Disconnect charging source prior to connecting or disconnecting the battery
- Disconnect Device Requirement – for PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily
- The maximum ambient operating temperature of the product is 104 °F (40 °C).
- Do not use surge protectors or extension cords with the
- Do not use for medical or life support
- Do not use with or near
- Do not use the product on transportation
- Intended for installation in a temperature-controlled, indoor area free of conductive
WARNING Risk of fire, explosion, or burns! Do not disassemble, heat above
140 °F (60 °C), or incinerate the battery.
CAUTION Risk of electric shock! Do not remove the cover except to replace
the battery. Turn off and unplug the product before replacing the batteries.
There are no user-serviceable parts inside except for the battery.
CAUTION Risk of fire! To reduce the risk of fire, connect only to a
circuit provided with 20 amperes maximum branch circuit overcurrent protection
in accordance with the National Electric Code, ANSI/NFPA 70. CAUTION Not
for use in a computer room as defined in the Standard for the protection of
information Technology Equipment, ANSI/NFPA 75
Additional Battery Warnings
- Keep batteries out of the reach of
- If the battery leaks avoid contact with skin and Rinse affected areas immediately with plenty of clean water, then consult a doctor.
- If the product appears to be bulging or shows other undesirable phenomena (e.g. excess noise), stop using it
- Do not cover while in
- Charge this product once every 3 months to avoid shortening its battery life
Symbols
| The provided battery contains Lead. Dispose of the battery according to
local regulations.
---|---
|
| Direct
current.
| Alternative current.
Before First Use
- Check for transport damages.
- Before connecting the product to the power supply, check that the power supply voltage and current rating corresponds with the power supply details shown on the product rating label.
- Choose a wall outlet that’s in a branch circuit protected by a fuse or a circuit breaker and does not connect in parallel to appliances or equipment with large power consumption.
DANGER Risk of suffocation! Keep any packaging materials away from
children – these materials are a potential source of danger, e.g. suffocation.
NOTICE To ensure the maximum battery’s capacity, it is recommended to
charge the battery for at least 24 hours before first use.
NOTICE The product is equipped with a delivery safety lock. The product
needs to be connected to the power supply before the initial start-up.
Operation
Connecting an external equipment
CAUTION Risk of damage! Do not connect equipment with a combined power
consumption of more than 1000 VA/550 W.
NOTICE It is suggested not to exceed 80% of the product’s total capacity
when connecting to the battery backup & surge protection outlets (I). Do not
connect larger appliances, such as laser printers, paper shredders, heaters,
etc. to battery backup & surge protection outlets (I). The power requirement
of such equipment might overload and potentially damage the product.
- Connect the external equipment to the product’s outlets (I) or/and (K).
- Connect the power plug (J) to the appropriate wall outlet.
Switching on/off
Battery backup & surge protection outlets (I)
The outlets (I) provide battery backup and surge protection. In case of a
power outage, battery power is automatically provided to these 5 outlet s.
- Press the power button (A). The product beeps and the ONLINE indicator (C) lights up. The product supplies the power to the connected equipment.
- The product now supplies the power to the connected equipment.
- In case of a power outage, the ON BATTERY indicator (E) lights up and the product beeps twice in 7 seconds to indicate the battery backup mode operation.
NOTICE If an overload is detected the product stops operation and the OVERLOAD indicator (F) lights up and the product beeps. Switch off the product and unplug at least one connected piece of equipment so that the maximum capacity is not exceeded. Wait 10 seconds and press the RESET button (L). Then switch on the product again.
Surge protection outlets (K)
The outlets (K) provide only surge protection. Those outlets do not provide
power during a power outage.
NOTICE The surge protection outlets (K) are constantly on, whenever the
product is connected to the power supply.
Status
1. Power outage | The product operates in the battery backup mode. |
---|---|
2. Low battery | The battery capacity is low. The battery will be |
drained quickly during a power outage.
3. Overload| Product rated capacity is exceeded. Switch off the product
and unplug at least one connected piece of equipment so that the maximum
capacity is not exceeded. Wait 10 seconds and press the RESET button (L). Then
switch on the product again.
4. Short fault| Switch off the product and unplug at least one
connected piece of equipment from the battery backup outlets. Then switch on
the product again.
5. Charge fault| The battery charging voltage is too high or too low.
Contact professional repair center.
Indicators patterns
Status | Online (C) | On Battery (E) | AVR (D) | Overload (F) | Alarm |
---|---|---|---|---|---|
1. | OFF | Flashes while beeping | OFF | OFF | Beeps twice every 30 seconds |
2. | OFF | Flashes while beeping | OFF | OFF | Beeps rapidly |
3. | ON | OFF | OFF | ON | Constant alarm |
OFF | ON | ||||
4. | ON | OFF | OFF | OFF | Constant alarm |
OFF | ON | ||||
5. | ON | OFF | OFF | OFF | Beeps every 2 seconds |
OFF | ON |
Automatic voltage regulation
The product features AVR (Automatic Voltage Regulation) that allows stabilizing the inconsistent power input to the nominal level (110-120 V~) that is safe to the connected external equipment. Once the AVR protection is activated the AVR indicator (D) lights up.
Sensitivity adjustment
Inline mode, the AC input voltage can not be stable all the time. To prevent the connected equipment from damage caused by the unexpected voltage fluctuations, adjust the sensitivity of the product.
- Switch the product on in the line mode.
- Press the MUTE button (B) for 6 seconds. All indicators flash rapidly.
- The product indicates the current sensitivity setting:
Indicators | Sensitivity | Description |
---|---|---|
Red | Low | If the connected equipment can tolerate more power events (e.g. |
unstable power in stormy weather), select Low Sensitivity, and the product
will go to Battery Mode less often.
Yellow, red| Medium (Default)| The product will go to Battery Mode if the
power is unstable.
Green, yellow, red| High| If the connected equipment is more sensitive to
power events, select High Sensitivity, and the product will go to Battery Mode
more often.
- To change the setting, press the MUTE button (B) repeatedly.
- To save the setting, press and hold the MUTE button (B) until the
ONLINE indicator (C) lights up.
NOTICE The product exits the sensitivity setup automatically if no button
is pressed for 7 seconds.
Connecting to a computer
NOTICE The PowerPanel ® Personal software enables to view of the
connection and energy consumption status as well as configure the product. Use
the type B to type A USB cable to connect the product to a computer.
Download and installation
- Visit www.amazon.com website.
- Search the B07RRYB3RJ product number.
- Scroll down to the “Technical Specification” section and download the PowerPanel ® Personal software.
- Launch the software and follow the on-screen setup instructions.
Replacing the battery
Replacing the battery
CAUTION Risk of Energy Hazard! 12 V, 9 Ampere-hour battery. Before
replacing batteries, remove conductive jewelry such as chains, wrist watches,
and rings. High energy through conductive materials could cause severe burns.
CAUTION Risk of explosion! Do not dispose of batteries in a fire. The
batteries may explode.
CAUTION Risk of injury! Do not open or mutilate batteries. Released
material is harmful to the skin and eyes. It may be toxic.
CAUTION Risk of electric shock! A battery can present a risk of
electrical shock and a high short circuit current. The following precautions
should be observed when working on batteries:
- Remove watches rings or other metal objects.
- Use tools with insulated handles.
NOTICE When replacing batteries, replace with the same number of the following battery: amazonbasics/ABRB 1290.
- Switch off and unplug all the connected equipment.
- Switch off the product and disconnect it from the power supply.
- Place the product on its side, on a solid and stable surface.
- Loosen the battery compartment cover screws.
- Slide the battery compartment cover and put it aside.
- Slide the battery out of the battery compartment.
-
Slide the replacement battery into the battery compartment.
-
Connect the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the new battery.
-
Close the battery compartment cover and secure it with the screws.
WARNING Risk of explosion! Always connect the (+) red connector and (-) black connector to the correct terminals (+) and (-).
Cleaning and Maintenance
NOTICE Switch the product off and unplug it from the power supply before
cleaning.
NOTICE During cleaning do not immerse the product in water or other
liquids. Never hold the product under running water.
Cleaning
- To clean, wipe with a soft, slightly moist cloth.
- Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product.
Maintenance
- Replace the battery after 3-6 years of use. Storage
- Store the product covered in a cool, dry location, with the battery fully charged. Fully charge the battery every 3 months. Transport
- Switch off and disconnect all the connected equipment. Disconnect the product from the power supply and then disconnect all the internal batteries.
- Pack and secure the product properly to protect it from shocks and vibrations.
System Functional Block Diagram
Troubleshooting
Problem
| Possible cause| Solution
---|---|---
The circuit breaker has tripped.| Power supply overload.| Switch off the
product and unplug at least one connected piece of equipment so that the
maximum capacity is not exceeded. Wait 10 seconds and press the RESET button
(L). Switch on the product again.
The product does not perform the expected runtime.| The battery is not fully
charged.| Recharge the battery.
The battery is worn out.| Replace the battery.
| The product is not connected to the socket outlet.| The product must be
connected to a 120 V, 60 Hz socket outlet.
The product does not switch on.
| The power button (A) is designed to prevent damage from rapidly turning it
off and on.| Switch off the product. Wait 10 seconds and switch on the product
again.
| The battery is worn out.| Replace the battery.
| The USB / serial cable is not connected.| Connect the USB / serial cable to
the product and a USB port of your computer.
PowerPanel® Personal software is inactive (all icons are gray).| The USB /
serial cable is connected to the wrong port.| Connect the USB / serial cable
to another USB port of your computer.
| The product is not providing battery power.| Switch off the product. Wait 10
seconds and press the RESET button (L). Switch on the product again.
FCC – Supplier’s Declaration of Conformity
Unique Identifier | B07RRYB3RJ – AMBT1000 |
---|---|
Responsible Party | Amazon.com Services, Inc |
U.S. Contact Information | 410 Terry Ave N. Seattle, WA 98109, United States |
Telephone Number | 206-266-1000 |
FCC Compliance Statement
- This device complies with Part 15 of the FCC Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
- Consult the dealer or an experienced radio/TV technician for help
Canada IC Notice
- This Class B digital apparatus complies with Canadian CAN ICES-3(B) / NMB-3(B) standard
Specifications
Model number: | ABMT1000 |
---|---|
Input voltage/frequency: | 120 V~, 57 Hz (± 0.5 Hz) – 63 Hz (± 0.5 Hz) |
Battery backup mode output voltage/frequency: | 120 V~ (± 5%), 60 Hz (± 1 %) |
Power capacity: | 1000 VA, 550 W |
Maximum load for the surge protection outlets (K): | 12 A |
Battery type/voltage/capacity: | Maintenance-free sealed lead-acid battery 12 |
V, 9 AH
Standby use: 13.5-13.8 V Cycle use: 14.4-15 V
Initial current: less than 2.7 A
Battery backup mode waveform:| Simulated sine wave
Estimated backup battery time:| Half Load (275 W) – 1 minute Full Load (550 W)
– 7 minutes
Battery charging time:| 24 hours to 90% from full discharge
Operating temperature:| 32 °F to 104 °F (0 °C to 40 °C)
Operating humidity:| 10 – 95 % RH
Net weight:| 15 lbs (6.8 kg)
Dimensions (W x H x D):| 3.9 x 9 x 10.2″ (10 x 22.8 x 26 cm)
Feedback and Help
Love it? Hate it? Let us know with a customer review. AmazonBasics is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the product.
| amazon.com/review/review-your-purchases#
---|---
| amazon.com/gp/help/customer/contact-us
Documents / Resources
|
amazonbasics B07RRYB3RJ Line-Interactive UPS 1000VA 550 Watt, 9
Outlets
[pdf] User Guide
Line-Interactive UPS 1000VA 550 Watt 9 Outlets, B07RRYB3RJ, K01-1198009-01
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>