Z-Wave HS1SA-Z Smart Smoke Sensor User Guide
- June 7, 2024
- Z-Wave
Table of Contents
- HS1SA-Z
- 1-Device Inclusion
- 2-Device Exclusion
- 3-Device test mode
- 4-Device detection mode
- 5-Device Factory Reset
- 6-Association & Association Group Information
- 7-Notification Report
- 8-Battery Report
- 9-Wake up Notification
- 10-Devices from multiple manufacturers in one network
- 11-Z-Wave Specifications
- 12-Indicate LED statues description-
- 13-How to replace the batteries
- 14-Technical Specifications
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HS1SA-Z
Z-Wave Device
Guide Document
1-Device Inclusion
– Click [Add] icon in Z-Wave PC Controller Program.
– Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times
within 1 second.
– If Inclusion Process is successful, Green led will turn off.
2-Device Exclusion
– Click [Remove] icon in Z-Wave PC Controller Program
– Press the Net_Button 3 times within 1.5s
– If Exclusion Process is successful, Green led is Blinking 6 times, then turn
off.
3-Device test mode
if Inclusion process is successful, Press Test_Button to test if the device is working normally.
Red LED blinks 3 times when smoke is detected.
4-Device detection mode
if Inclusion process is successful, the device will report alarm information if detect the status change of smoke and no smoke . Red LED blinks quickly when smoke is detected.
5-Device Factory Reset
– Long press Net_Button while installing batteries in HS1SA-Z.
– Device Reset Locally notification is Transmitted.
– Please use this procedure only when the network primary controller is
missing or otherwise inoperable.
6-Association & Association Group Information
– Lifeline between controller and HS1SA-Z
– Supported command classes
Battery report, Notification report, and Device Reset Locally notification, Binary report.
– Maximum supported nodes are 5.
– Association Group description
Association group 1: Lifeline association group
Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report.
Association group 2: Root Device group(Binary Sensor)
Binary Sensor Command Class: Compatible with 300 series
1- Binary Sensor reports status of smoke or no smoke via Lifeline.
2-When the sensor detects status change between smoke and no smoke, the device
will be triggered.
Association group 3: Root Device group(Notification)
1- Notification reports reports status of detect smoke or no smoke via
Lifeline.
2- When the sensor detects status change between smoke and no smoke, the
device will be triggered.
7-Notification Report
-Press or release test button, or smoke status is changed(smoke detected or no smoke detected) , Notification Report is transmitted
Notification Type | Event |
---|---|
Smoke Alarm (0x01) | Previous Events cleared ( 0x00) |
Smoke detected, Unknown Location(0x02)
8-Battery Report
– Battery Report is transmitted when power on the device.
– Battery Report is transmitted once a day.
– Battery Report is transmitted when the battery falls less than 10%
Battery Voltage Battery Level
2.4V ~ 3.0V 10~ 100 (%)
Under 2.4V 0xFF
9-Wake up Notification
– Wake up Notification is transmitted every 24 hours by default.
– Wake up Notification is transmitted after Notification Report is Transmitted
10-Devices from multiple manufacturers in one network
– This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applicants. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
11-Z-Wave Specifications
- Device Type : Sensor – Notification
- Role Type : RSS (Reporting Sleeping Slave)
- Command Class Support/Control
Z-Wave plus info
Version
Manufacture Specific
Notification
Device Reset Locally
Association Group Information
• Association
Battery
Wake Up
Power Level
• Binary Sensor
12-Indicate LED statues description-
Status
| LED status|
Alarm sound
---|---|---
Normal| Red LED flash every 53s| No sound
Test mode| Red LED flash quickly| Sound“Di-Di-Di”loudly
Alarm| Red LED flash quickly| Sound“Di-Di-Di”loudly
Silence mode| Red LED flash 1 time every 10 seconds| No sound
Low battery| Red LED flash 1 time every 53 seconds| Sound “Di” every 53
seconds
Fault| Red LED flash 2 times every 53 seconds| Sound “Di” twice every 53
seconds
13-How to replace the batteries
Turn right to dismantle the mounting base of the device
- take out battery from the device
- Insert the battery into the device
(You must be careful of the battery polarity)
Turn left to install the mounting base of the device
(before install the mounting base, you should must insert battery firstly ,
otherwise the mounting base will not be fixed)
14-Technical Specifications
Model No. | HS1SA-Z |
---|---|
RF frequency | 868.40- 869.85 MHz |
RF operating distance | Up to 100m outdoor line of sight Up to 40m indoor |
Powered by | 1 x CR123A |
Temperature | -10℃~ 50℃ |
Humidity | 95% max |
Weight | 69.2g (batteries) |
Read User Manual Online (PDF format)