Hyperice Normatec 2.0 Pro Leg Recovery System Instruction Manual
- June 7, 2024
- Hyperice
Table of Contents
- WARNINGS
- LABELS
- INDICATIONS FOR USE
- RISKS AND BENEFITS OF THE NORMATEC 2.0 PRO SYSTEM
- ILLUSTRATIONS
- OPERATING INSTRUCTIONS
- SET UP THE SYSTEM
- CHOOSE YOUR ATTACHMENT
- ADJUST THE MODE
- ADJUST THE INTENSITY
- ADJUST THE SESSION TIME
- TURN OFF BLUETOOTH WIRELESS TECHNOLOGY
- START THE SESSION
- STOP OR PAUSE THE SESSION
- FINISH THE SESSION
- TURN OFF THE CONTROL UNIT
- USE ZONE BOOST
- USE CUSTOM MODE
- ADJUST THE REST TIME
- CHANGE THE MASSAGE PATTERN
- PATENTED NORMATEC PULSE MASSAGE PATTERN
- SEQUENTIAL MASSAGE PATTERN
- ADJUST THE NUMBER OF ZONES
- ADJUST DISPLAY BRIGHTNESS
- RESTORE DEFAULT SETTINGS
- VIEW CURRENT PRESSURE AND TIME
- VIEW CONTROL UNIT USAGE
- CARING FOR THE SYSTEM
- BLUETOOTH WIRELESS TECHNOLOGY
- INTERNAL BATTERY INFORMATION
- PRODUCT SPECIFICATIONS
- ELECTROMAGNETIC COMPATIBILITY
- GENERAL NOTES
- ELECTROMAGNETIC EMISSIONS
- ELECTROMAGNETIC IMMUNITY
- RECOMMENDED SEPARATION DISTANCES
- EQUIPMENT CLASSIFICATION
- TROUBLESHOOTING
- WARRANTY INFORMATION
- RETURN POLICY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hyperice Normatec 2.0 Pro Leg Recovery System
WARNINGS
Read the entire instruction manual before using the Normatec 2.0 Pro System.
| WARNING! No modification of this equipment is allowed.
---|---
| WARNING! If you experience severe pain, any unusual symptoms, or want
to remove the attachments in an emergency during use:
---|---
- Stop the control unit by pressing the power button.
- Disconnect the hose from either the control unit or the attachments.
- Remove the attachments from your limbs.
- Promptly consult your licensed healthcare practitioner, as required.
CAUTION
-
Do not attempt to take apart the system. The system has no user-serviceable parts. When service or repairs are required, please contact customer service at +1.949.565.4994.
-
Only use the power supply provided with the system. Using a different power supply may cause the system to operate incorrectly.
-
To avoid risk of electric shock, do not use the system near water, such as near a bathtub, kitchen sink, laundry tub, or swimming pool.
-
To avoid damage and risk of electric shock, never spill liquid of any kind on the system.
-
Do not place the system, power supply, or any accessories where they could be damaged, present a fall hazard, or become an obstruction to others.
-
Keep the open ports of the control unit, hose interconnect, and power inlet free of debris.
-
If the power supply is damaged, the control unit is dropped or damaged, liquid is spilled on the system, or if the system does not operate normally when the operating instructions are followed, turn the system off by pushing the control unit’s power button and then unplugging the system from the wall outlet. Contact customer service at +1.949.565.4994 for assistance.
-
Do not puncture or otherwise damage the attachments (legs, arms, hips, or custom attachments) since this may cause the system to operate incorrectly.
-
To avoid risk of strangulation, do not leave a baby or child unattended with the power supply or hose.
-
Choking hazard, small parts. Keep away from small children.
-
Do not leave the system, power supply, or any accessories where they could be damaged by children, pets, pests, or liquids. If you suspect your control unit is damaged, contact customer service at +1.949.565.4994 for assistance.
-
Do not allow lint or dust to accumulate on the control unit or the hose interconnects. If lint or dust accumulates, wipe down the system with a dry cloth before use.
-
The IP21 classification means the control unit is protected against the ingress of vertically dripping water and the hazardous parts are protected against access to objects equal to or larger than 12.5 mm (1/2″).
-
The expected service life of the system and the integrated battery is 3 years.
-
Do not walk while wearing the attachments.
-
The attachments are designed to be used by only one person at a time.
-
Do not hold the unit by the hose.
-
Consult your physician before using this product if you are under the care of a physician or have a contraindication requiring the use of any medical control unit.
-
Consult your physician before using this product if you are experiencing inflammation, an infection, pain of unknown origin,
bleeding (internal or external) at or near the site of application, or if you have a wound at or near the site of application. -
Consult your physician before using this product on sensitive skin.
-
Consult your physician before using this product if you have any of the following conditions:
○ Acute pulmonary edema
○ Acute thrombophlebitis
○ Acute congestive cardiac failure
○ Acute infections
○ Deep vein thrombosis (DVT)
○ Episodes of pulmonary embolism
○ Wounds, lesions, or tumors at or near the site of application
○ Where increased venous and lymphatic return is undesirable
○ Bone fractures or dislocations at or near the site of application -
This product contains a lithium ion battery. Dispose of this product in accordance with local regulations.
-
Do not use the control unit air output or hose to direct pressurized air toward your eyes, nose, mouth, or ears. Doing so may lead to serious injury.
-
Use by unconscious or incapacitated persons may be dangerous without supervision.
-
Make sure the power inlet on the control unit is easily accessible at all times in order to disconnect power if required.
The Normatec 2.0 Pro control unit contains a Li-ion battery and, if discarded, needs to be disposed of in accordance with local regulations.
Save this manual for future reference.
LABELS
The following labels and symbols appear on the control unit, garments, and/or packaging.
Symbol
| Description|
Location
---|---|---
| Degree of protection against ingress of water| On base of control unit
| Read instructions before use| On base of control unit and attachment tag
| Level of protection type BF equipment| On base of control unit
| Double insulation| On power adapter
| Direct current| On base of control unit
| Alternating current| In manual
| Manufacturer’s name and address| On base of control unit and attachment tag
| Date of manufacture| On base of control unit
| Separate collection for waste electrical and electronic equipment| On base
of control unit
| Serial number of the
console| On base of control unit
| Fragile, handle with care| On package
| Keep dry| On package
| This side up| On package
|
Keep away from sunlight| On package
| Transportation & storage humidity limitation| On package
| Transportation & storage atmospheric pressure limitation| On package
| Transportation & storage temperature limitation| On package
| Place in and out of standby mode| On top of control unit
| Do not wash| On attachment tag
| Do not dry clean| On attachment tag
| Do not tumble dry| On attachment tag
| Do not bleach| On attachment tag
| Do not iron| On attachment tag
| Zone Boost icon| On control unit
| EU RF transmitter symbol| In manual
| FCC approved equipment authorization| On control unit
| The Bluetooth figure mark| On control unit
| Warning symbol to identify a hazard that may lead to death or serious
injury| In manual and on control unit
| Caution symbol to indicate the need for the user to consult the instructions
for use for important cautionary information such as warnings and precautions
that cannot, for a variety of reasons, be presented on the medical control
unit itself| In manual
| Tip to provide guidance to make use easier. Risk to user is considered
negligible| In manual
INDICATIONS FOR USE
The Normatec 2.0 Pro System is an air pressure massager indicated to temporarily relieve minor muscle aches and/or pains and to temporarily increase circulation to the treated areas.
RISKS AND BENEFITS OF THE NORMATEC 2.0 PRO SYSTEM
The risks and benefits of using the Normatec 2.0 Pro System are the same as having a massage. If the Normatec 2.0 Pro massage feels uncomfortable, you can reduce the intensity or stop the session. Similar to a massage, the benefits include the temporary relief of minor muscle aches and pains. It also temporarily increases circulation in the area being massaged. Please call customer service at +1.949.565.4994 if you have any questions.
ILLUSTRATIONS
Normatec 2.0 Pro Control Unit (single-person use only)
- Power button and Bluetooth button
- Touchscreen
- Air outlet and power inlet
Normatec 2.0 Pro Hose (single-person use only)
- Junction box air outlets
- Junction box
- Blocking plug (on the underside of the junction box)
- Connector
Normatec 2.0 Pro Leg Attachment (single-person use only)
- Attachment connector
- Zones
Normatec 2.0 Pro Arm Attachment (single-person use only)
- Attachment connector
- Zones
Normatec 2.0 Pro Hip Attachment (single-person use only)
- Attachment connectors
- Zones
Normatec 2.0 Pro Power Supply
- Wall outlet plug
- Barrel connector
OPERATING INSTRUCTIONS
WARNING! BEFORE OPERATING THIS CONTROL UNIT: Read all warnings at the beginning of this manual. If you do not understand these operating instructions, contact Hyperice at +1.949.565.4994.
SET UP THE SYSTEM
-
Step 1: Plug the power supply into an electrical outlet and then into the Normatec 2.0 Pro control unit.
This control unit is equipped with a lithium ion battery. The battery automatically charges when the power supply is connected to the Normatec 2.0 Pro control unit and an electrical outlet. -
Step 2: Connect the hose connector to the air outlet on the Normatec 2.0 Pro control unit. The connector can only be inserted in the correct orientation. Insert the connector firmly into the Normatec 2.0 Pro control unit until you hear an audible “click.”
-
Step 3: Put the leg, arm, or hip attachments on. Find a comfortable position sitting, reclined, or lying down. If the attachments have a zipper, be sure to zip up the attachments completely. Never try to use the system with the zipper partially or totally unzipped–this could void your warranty. Only one set of attachments can be used with a single control unit. When using more than one attachment, make sure they are both of the same type.
-
Step 4: Connect the attachment connectors on each attachment to the junction box air outlets. The attachment connectors can only be connected to the junction box in the correct orientation. Insert the attachment connectors firmly into the junction box air outlets until you hear an audible “click.”
-
If only one attachment will be connected to the junction box, use the blocking plug located on the underside of the junction box to block off the unused junction box air outlet. Press firmly to make sure the blocking plug is fully seated.|
-
Step 5: Press the power button on the Normatec 2.0 Pro control unit firmly for one second to turn on the system.
While the control unit is on, the green LED next to the power button will be lit up.
CHOOSE YOUR ATTACHMENT
Select the attachment you are using by tapping on the menu icon in the upper left, and selecting the attachment option. Tap an attachment to select it. You can quickly identify which attachment is currently selected by looking at the attachment graphic on the home screen.
ADJUST THE MODE
Adjust the mode by tapping on the menu icon in the upper left, and selecting the recovery mode option. The mode selection screen will open. The active mode will be highlighted in blue. To change the mode, tap on the desired mode.
- Recovery Flush: Use Recovery Flush for a quick recovery session.
- Rehab: Use Rehab Mode to select pre-programmed sessions designed for specific applications. When you select Rehab Mode, you will be prompted with additional options depending on which attachment you have selected.
- Custom: Use Custom Mode to program your own settings. See the Custom Mode section (page 9) for details on how to use this mode. This option can only be adjusted before a session starts.
ADJUST THE INTENSITY
Adjust the intensity level of the session by pressing the level adjustment buttons on the left and right of the level indicator. Intensity level 1 is the gentlest setting. The massage becomes stronger as the intensity level is increased. Intensity can be adjusted while the session is running. When the level is adjusted during a session, the system will stop for 10 seconds and the cycle will resume at the new pressure.
ADJUST THE SESSION TIME
Adjust the session time by pressing the time adjustment buttons on the left and right of the time indicator. The session time can be set between 10 minutes and 2 hours and 55 minutes (in 5-minute increments). A typical session time is between 15 and 60 minutes long. Setting the time longer than 2 hours 55 minutes will put the control unit into Continuous Mode. To turn off Continuous Mode, decrease the time. In Continuous Mode, the screen will display CONTINUOUS instead of the timer, and will begin counting up from zero when the session starts. Time can be adjusted while the session is running. Tap the time adjustment buttons to add or subtract time from the session in 5-minute increments.
TURN OFF BLUETOOTH WIRELESS TECHNOLOGY
To disable Bluetooth wireless technology on the device, press and hold the Bluetooth button on the top of the device for ten seconds. The Bluetooth icon will disappear from the screen when it is disabled.
START THE SESSION
To start the session, tap the start button on the home screen.
STOP OR PAUSE THE SESSION
To stop the session at any time, tap the pause button on the home screen. This
will temporarily stop the session. To resume a paused session, tap the resume
button. To end a session, tap the pause button and then tap the quit button.
If you are done using the system, remove the attachments from the hose, remove
the attachments from your limbs, turn off the control unit by pressing the
power button, and disconnect the hose from the control unit.
To disconnect connectors from the junction box or the control unit, push the
button on the top of each connector while pulling away.
FINISH THE SESSION
The session will continue massaging until the time on the home screen reads
00:00:00 and the current cycle is completed. While the current cycle is being
completed, cycle finishing will be displayed on the home screen. To stop the
session immediately, tap the stop button. To extend the session, tap the
button to the right of the time to add minutes. Once the session is complete,
the control unit will reset to the original session time. When the session is
completed, remove the attachments from the hose, remove the attachments from
your limbs, turn off the control unit by pressing the power button, and
disconnect the hose from the control unit.
To disconnect connectors from the junction box or the control unit, push the
button on the top of each connector while pulling away.
TURN OFF THE CONTROL UNIT
To turn off the system, press the power button and confirm that the green power LED is shut off.
USE ZONE BOOST
During your session, you can increase the intensity of a single zone with the Zone Boost feature. Zone Boost is designed to be used when you want extra attention in a specific area. Zone Boost will add an extra 60 seconds of massage time, as well as 10 mmHg increased pressure, in the selected zone.
Activate Zone Boost: Tap the zone you wish to boost on the attachment graphic on the home screen. Only one zone can be boosted at a time. Zone Boost is only available with the patented NORMATEC PULSE massage pattern. Boosted zones will appear with the Zone Boost indicator on either side of the boosted zone ( Figure 1) on the control unit’s home screen.
Deactivate Zone Boost: Tap once on the boosted zone.
USE CUSTOM MODE
When entering Custom Mode (only available when in the patented NORMATEC PULSE
massage pattern) the time and pressure is displayed to the right of each zone.
Starting with zone 1, tap on the button to the left of the zone to adjust that
zone’s settings. Use the and buttons on the subsequent screen to adjust the
pressure and time for that zone, and then tap the back button to return to the
custom screen. Repeat for all zones that you wish to adjust.
Starting from the foot, hand, or thigh (depending on the attachment selected),
each zone cannot be set more than 10 mmHg higher than the previous zone.
ADJUST THE REST TIME
Adjust the rest time by tapping on the menu icon in the upper left and selecting the advanced options button. On the next menu, select the rest time option. The rest time adjustment screen will open. Use the and buttons to increase or decrease the rest time between 15 and 90 seconds. This option can only be adjusted before a session starts. The default rest time is 30 seconds.
CHANGE THE MASSAGE PATTERN
Adjust the massage pattern by tapping on the menu icon in the upper left and selecting the advanced options button. On the next menu, select the massage pattern option. The massage pattern screen will open. Select the pattern you wish to use. This option can only be adjusted before a session starts. The selected massage pattern is highlighted in blue.
PATENTED NORMATEC PULSE MASSAGE PATTERN
Before the patented NORMATEC PULSE massage pattern begins, you will experience
a pre-inflate cycle, during which the connected attachments are molded to your
exact body shape. Once the pre-inflate cycle is complete, the patented
NORMATEC PULSE massage pattern will begin by compressing your feet, hands, or
upper quad (depending on which attachment you are using). Similar to the
kneading and stroking performed during a massage, each zone of the attachments
will first compress in a pulsing manner and then release as the compression
pattern works its way up your limb. When the top zone completes its massage,
there will be a brief rest period and then the cycle will begin again. This
will repeat until the session time runs out.
When the session is resumed after a pause, the system will perform a pre-
inflate cycle before continuing.
SEQUENTIAL MASSAGE PATTERN
The SEQUENTIAL massage pattern begins by compressing your feet, hands, or upper quad (depending on which attachment you are using). Each zone of the attachments will compress and hold pressure. This will repeat for each zone of the attachments as the compression pattern works its way up your limb.
ADJUST THE NUMBER OF ZONES
The number of attachment zones that are enabled can be changed between one and five zones. Zones can be disabled from the top to the bottom of the attachment, one zone at a time. Zone adjustments remain after you turn off the control unit. Adjust the number of zones by tapping on the menu icon in the upper left and selecting the advanced options button. On the next menu, select the number of zones option. The number of zones screen will open. Use the and buttons to increase or decrease the number of enabled zones. At least one zone must be enabled. Enabled zones are solid blue, disabled zones are solid gray. This option can only be adjusted before a session starts.
ADJUST DISPLAY BRIGHTNESS
Adjust the display brightness by tapping on the menu icon in the upper left
and selecting the control unit preferences button. On the next menu, select
the display brightness option. The display brightness screen will open. Use
the and
buttons to adjust the display brightness between level 1 and 10. Brightness
level 1 is the darkest and level 10 is the brightest.
RESTORE DEFAULT SETTINGS
Reset the control unit to factory settings by tapping on the menu icon in the upper left and selecting the control unit preferences button. On the next menu, select the factory reset option. The factory reset screen will open. Tap the reset control unit button, and then the Yes, reset control unit button to confirm the reset. This option can only be adjusted before a session starts.
VIEW CURRENT PRESSURE AND TIME
View the current settings for pressure and time by tapping on the menu icon in the upper left of the home screen and selecting the current settings option.
VIEW CONTROL UNIT USAGE
View the control unit usage by tapping on the menu icon in the upper left and selecting the control unit preferences option. On the next menu, select the control unit usage option. The control unit usage screen will open. The total control unit usage since last reset will be displayed. The usage can be reset to zero by pressing the reset usage button.
CARING FOR THE SYSTEM
CLEANING THE SYSTEM
To clean the control unit:
- Wipe down the system with a damp, clean cloth.
- Dry thoroughly with a clean cloth.
Cleaning the single-person use leg, arm, or hip attachments:
- Wipe down the legs, arms, or hip attachments inside and out with a damp, clean cloth. Dry thoroughly with a clean cloth.
- Do not machine wash or dry. · Do not dry clean.
MAINTAINING THE SYSTEM
The control unit, hose, power supply, and attachments (legs, arms, or hips) require no routine maintenance or service except for the care in this section.
STORING THE SYSTEM
Store control unit, hose, power supply, and attachments (legs, arms, or hips) in a clean, dry location.
REPLACEMENT PARTS
Please call customer service at +1.949.565.4994 or visit our website at.hyperice.com for information regarding available replacement parts and accessories.
TECHNICAL INFORMATION
Do not attempt to take apart the system. The system has no user-serviceable parts. There are no user-replaceable fuses.
BLUETOOTH WIRELESS TECHNOLOGY
The Bluetooth word mark and logos are owned by Bluetooth SIG, Inc., and any use of such marks by Hyperice is under license. In the unlikely event of loss of a stable Bluetooth connection, the system will attempt to re-establish its connection automatically. The Normatec 2.0 Pro control unit is completely autonomous, and will continue operating normally, even during a loss of connectivity. If this control unit does cause interference, which can be determined by turning the control unit off and on, the user is encouraged to try to correct the interference by reorienting or relocating the control unit, increasing the separation between equipment and the control unit, or connecting the control unit to a different outlet on a circuit if it is plugged in.
The Normatec 2.0 Pro control unit uses Bluetooth 5.0 wireless technology with the following radio specifications:
Frequency | 2.36 to 2.5 GHz |
---|---|
Modulations | GFSK at 1 Mbps, 2 Mbps data rates |
Transmit Power | +4 dBm |
Receiver Sensitivity | BMD-300/301: -96 dBm (BLE mode) BMD-350: -94 dBm (BLE |
mode)
Security| AES-128
Contains Rigado, Inc. BLE Module BMD-300-A-R, FCC ID: 2AA9B04, IC ID: 12208A-04
This control unit complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this control unit may not cause harmful interference, and (2) this control unit must accept any interference received, including interference that may cause undesired operation.
This control unit complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this control unit may not cause interference, and (2) this control unit must accept any interference, including interference that may cause undesired operation of the control unit.
INTERNAL BATTERY INFORMATION
This Normatec 2.0 Pro control unit is equipped with a rechargeable lithium ion battery. The internal battery is designed to allow use of the Normatec 2.0 Pro System anywhere–even when power outlets aren’t available. The Normatec 2.0 Pro control unit may need to be plugged in before first use. The battery will provide power for 2+ hours of continuous use. It takes approximately 6 hours to fully charge the battery when the control unit is plugged in and not in use. The rechargeable lithium ion battery is intended to be changed only by authorized service personnel with the use of a special service tool.
PRODUCT SPECIFICATIONS
- Normatec 2.0 Pro Dimensions: 4″ (width), 4.5″ (depth), 8″ (height); [10.2 cm (width), 11.43 cm (depth), 20.32 cm (height)]
- Normatec 2.0 Pro Weight: 3.6 lbs [1.63 kg]
- Normatec 2.0 Pro electrical requirement: 15V DC 1 A
- Temperature (operating): +41° F to 104° F [+5° C to +40° C]
- Temperature (storage): -13° F to +158° F [-25° C to +70° C]
- Relative Humidity (operating): 15% to 93%, non-condensing
- Relative Humidity (storage): -25° C without relative humidity control; +70° C at relative humidity up to 93%, non- condensing
- Atmospheric pressure (storage and transportation): 190hPa to 1060hPa
- Atmospheric pressure (operating): 700hPa to 1060hPa
AC-DC ADAPTER
WARNING! Only use the AC-DC adapter model number 30120 provided with the system. Using a different adapter may cause the system to not operate correctly.
- Input: 100-240V 0.8-0.4 A 50/60 Hz per Normatec 2.0 Pro model number 60090-001-00
- Output: 15V DC minimum 1.6 A per Normatec 2.0 Pro model number 60090-001-00
ELECTROMAGNETIC COMPATIBILITY
The information contained in this section (such as separation distances) is in general specifically written with regard to the Normatec 2.0 Pro. The numbers provided will not guarantee faultless operation but should provide reasonable assurance of such. This information may not be applicable to other medical electrical equipment; older equipment may be particularly susceptible to interference.
GENERAL NOTES
Medical electrical equipment requires special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided in this document and the remainder of the instructions for use of this control unit. Portable and mobile RF communications equipment can affect medical electrical equipment. Cables and accessories not specified within the instructions for use are not authorized. Using other cables and/or accessories may adversely impact safety, performance, and electromagnetic compatibility (increased emission and decreased immunity). Care should be taken if the equipment is used adjacent to or stacked with other equipment; if adjacent or stacked use is inevitable, the equipment should be observed to verify normal operation in the configuration in which it will be used.
ELECTROMAGNETIC EMISSIONS
This equipment is intended for use in the electromagnetic environment specified below. The user of this equipment should assure that it is used in such an environment.
Emissions | Compliance According To | Electromagnetic Environment |
---|---|---|
RF emissions (CISPR 11) | Group 1 | The equipment uses RF energy only for its |
internal function. Therefore, its RF emissions are very low and are not likely
to cause any interference in nearby electronic equipment.
CISPR emissions
classification
| Class B| The equipment is suitable for use in all establishments, including
domestic establishments and those directly connected to the public low-voltage
power supply network that supplies buildings used for domestic purposes.
Harmonic emissions (IEC 61000-3-2)| Class A
Voltage fluctuations/ flicker (IEC 61000-3-3)| Complies
ELECTROMAGNETIC IMMUNITY
This equipment is intended for use in the electromagnetic environment specified below. The user of this equipment should assure that it is used in such an environment.
Immunity Against| IEC 60601-1-2 Test Level| Compliance Level (of
this control unit)| Electromagnetic Environment
---|---|---|---
Electrostatic discharge, ESD (IEC 61000-4-2)| Contact Discharge:
± 8 kV
Air Discharge:
± 15 kV| ± 8 kV
± 15 kV| Floors should be wood, concrete, or ceramic tile. If floors are
covered with synthetic material, the relative humidity should be kept at
levels to reduce electrostatic charge to suitable levels.
Electrical fast transients/bursts (IEC 61000-4-4)| Power Supply Lines: ± 2 kV
Input DC Power Ports ± 2 kV Signal Input/Output Lines: ± 1 kV| ± 2 kV
± 2 kV
± 1 kV| Mains power quality should be that of a typical commercial or hospital
environment.
RF Proximity (IEC 61000-4-3)| 385 Pulse Modulation, 18 Hz
450 FM + 5Hz deviation: 1 kHz
sine
710
745
780 Pulse Modulation: 217 Hz
810
870
930 Pulse Modulation: 18 Hz
17201845
1970
Pulse Modulation: 217 Hz
2450 Pulse Modulation: 217 Hz
5240
5500
5785 Pulse Modulation: 217 Hz| 27 V/m
28 V/m
9 V/m
28 V/m
28 V/m
28 V/m
9 V/m| Equipment with high RF emissions should be kept at a distance to reduce
the likelihood of interference.
Surges on AC mains lines
(IEC 61000-4-5)
| Common Mode: ± 2 kV Differential Mode: ± 1 kV| ± 2 kV
± 1 kV| Mains power quality should be that of a typical commercial or hospital
environment.
Power frequency magnetic field 50/60 Hz
(IEC 61000-4-8)
| 30 A/m| 30 A/m| Equipment that emits high levels of power line magnetic
fields (in excess of 3A/m) should be kept at a distance to reduce the
likelihood of interference.
Voltage dips and short interruptions on AC mains input lines
(IEC 61000-4-11)
| Dip > 95%, 0.5 cycles
Dip > 95%, 1 cycle
Dip 30%, 25 cycles (50 Hz)30 cycles (60 Hz)
Drops >95%, 250 cycles (50 Hz)
300 cycles (60 Hz)
| 0.5 cycles 1 cycle
25 cycles (50 Hz)
30 cycles (60 Hz)
250 cycles (50 Hz)
300 cycles (60 Hz)| Mains power should be that of a typical commercial or
hospital environment. If you require continued operation during power mains
interruptions, ensure that batteries are installed and charged.
Ensure that battery life exceeds longest anticipated power outages or provide
additional uninterruptiblepower source.
This equipment is intended for use in the electromagnetic environment
specified below.
The customer or the user of this equipment should assure that it is used in
such an environment.
Immunity Test| IEC 60601 Test Level| Compliance Level|
Electromagnetic Environment – Guidance
---|---|---|---
Conducted RF RF coupled into lines (IEC 61000-4-6) Radiated RF (IEC
61000-4-3)| 150 kHz to 80 MHz outside ISM bandsa 150 kHz to 80 MHz in ISM
bandsa| 3 Vrms| Portable and mobile RF communications equipment should be used
no closer to any part of the equipment, including cables, than the recommended
separation distance calculated from the equation applicable to the frequency
of the transmitter as below.
Recommended separation distance:
d=1.2/V1]√P
d=1.2/√P 80 MHz to 800MHz
d=2.3√P 800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site surveya, should be less than the compliance level in each
frequency ranged.
Interference may occur in the vicinity of equipment marked with the following
symbol:
a The ISM (industrial, scientific, and medical) bands between 150 kHz and 80
MHz are 6,765 MHz to 6,795 MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283
MHz; and 40,66 MHz to 40,70 MHz.
b Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and
FM radio broadcast, and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the
measured field strength in the location in which the equipment is used exceeds
the applicable RF compliance level above, the equipment should be observed to
verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the equipment.
RECOMMENDED SEPARATION DISTANCES
Recommended separation distances between portable and mobile RF communications equipment and the Normatec 2.0 Pro control unit.
Rated maximum output power of transmitter W
| Separation distance according to frequency of transmitters in meters
---|---
150 kHz – 80 MHz
d=1.2/V1]√P
| 80 MHz to 800MHz
d=1.2/V1]√P|
800 MHz to 2.5 GHz
d=2.3√P
0.01| 0.12| 0.12|
0.23
0.1
| 0.38| 0.38| 0.73
1| 1.2| 1.2|
2.3
10
| 3.8| 3.8| 7.3
100| 12| 12|
23
For transmitters rated at a maximum output power not listed above, the
recommended separation distance (d) in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher
frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects,
and people.
EQUIPMENT CLASSIFICATION
- Protection against electric shock: Class II/internally powered equipment
- Degree of protection against electric shock: Type BF applied part (control unit, leg, arm, and hip attachments)
- Ingress protection: IP21
- Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide
- Continuous operation
TROUBLESHOOTING
Problem | Possible Causes | Solutions |
---|---|---|
The system does not start | Power is not turned on | |
Power supply is not securely connected Faulty electrical wall outlet | Press |
the power button to turn the control unit on.
Check that the power supply is securely connected to the Normatec 2.0 Pro
control unit and the electrical outlet.
Check that the wall outlet works.
The attachments (legs, arms, or hips) do not inflate| The session has not been
started
The hose is not securely connected
The attachments have been damaged| Tap the start button to start the session.
Check that the hose is securely connected to the Normatec 2.0 Pro control unit
and that the attachments are securely connected to the junction box.
Check that the attachments do not have an air leak.
The system stopped pumping| The hose is not securely connected
The attachments have been damaged| Check that the hose is securely connected
to the Normatec 2.0 Pro control unit and that the attachments are securely
connected to the junction box.
Check that the attachments do not have an air leak.
Error Detected| Air leak| Check for leaks in the hose or attachment. Check
that the connectors are firmly connected.
Low Battery| Battery needs to be charged| Plug in the control unit to charge
the battery.
Please see page 11 for battery functionality.
Cannot establish or maintain a Bluetooth connection| Bluetooth is turned off|
Turn on Bluetooth on both the Normatec 2.0 Pro control unit and the phone
attempting to pair with the Normatec 2.0 Pro control unit.
WARRANTY INFORMATION
Normatec 2.0 Pro System Limited One-Year Warranty The Normatec 2.0 Pro control unit is warranted by Hyperice, a California corporation (“Hyperice”), against manufacturing defects in material and workmanship for a period of one years from the date of purchase from Hyperice. In the event of any such defect occurring during the warranty period, Hyperice will, at its option, (a) correct the defect by repair or by replacement of the applicable part or component that fails as a result of such defect, without charge for parts and labor; or (b) replace the control unit with one of the same or then current design.
The Normatec 2.0 Pro attachments and other accessories include the leg attachments, hip attachment, arm attachments, power supply, and hosing. Normatec 2.0 Pro attachments and other accessories are warranted by Hyperice against manufacturing defects in material and workmanship for a period of one year from the date of purchase from Hyperice. In the event of any such defect occurring during the warranty period, Hyperice will, at its option, (a) correct the defect by repair or by replacement of the applicable part or component that fails as a result of such defect, without charge for parts and labor; or (b) replace the control unit with one of the same or then current design.
The foregoing Warranties do not cover normal wear and tear or cosmetic damage, and are void if the control unit and/ or the attachments and other accessories (collectively, the “product”) are not used in accordance with the user manual, are otherwise misused or modified in any way, and/or are repaired or altered by anyone other than an authorized service representative of Hyperice. These Warranties expressly exclude transportation, shipping or insurance costs, or defects, damages, or failure resulting from misuse, abuse, improper or abnormal usage, or neglect.
EXCEPT AS PROVIDED ABOVE, HYPERICE MAKES NO EXPRESS WARRANTIES OR ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR USE, AND ARE LIMITED IN DURATION AS STATED ABOVE. EXCEPT AS EXPRESSLY STATED ABOVE, HYPERICE SHALL HAVE NO LIABILITY OR RESPONSIBILITY TO ITS CUSTOMER OR ANY OTHER PERSON OR ENTITY WITH RESPECT TO ANY LIABILITY, LOSS, OR DAMAGE CAUSED DIRECTLY OR INDIRECTLY BY USE OR PERFORMANCE OF THE PRODUCT OR ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT OR ANY BREACH OF THESE WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY DAMAGES RESULTING FROM INCONVENIENCE, LOSS OF TIME, PROPERTY, OR INCOME, OR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. These Warranties give you specific legal rights, and you may also have other rights, which vary from state to state. In the event of a product defect covered by the foregoing Warranties during the applicable warranty period, contact Hyperice at +1.949.565.4994 or customersupport@hyperice.com.
All replaced parts and products become the property of Hyperice. New or reconditioned parts and products may be used in the performance of Warranty service. Repaired or replaced parts and products are warranted for the remainder of the original warranty period only. You will be charged for repair or replacement of parts and products made after the expiration of the applicable Warranty period.
RETURN POLICY
This policy is only applicable if you are an end user and you purchased the equipment directly from Hyperice. In the unlikely event that you are not satisfied with your purchase, you may return it within thirty (30) days of the purchase date. If you purchase incorrectly sized attachments, they may be exchanged within fourteen (14) days of the purchase date. All returns and exchanges are subject to the conditions listed below.
- Returns and exchanges must have a Return Merchandise Authorization (RMA) number. Obtain an RMA number by contacting us at +1.949.565.4994 or customersupport@hyperice.com. Returned items without an RMA number will not be eligible for a credit to your account.
- Returns must be shipped within 30 days of the purchase date; exchanges must be shipped within 14 days of the purchase date.
- Products and packaging must be returned in new and undamaged condition. Any products showing signs of wear or being soiled in any way will be deemed “unacceptable,” and you will be so notified. Unacceptable returns and/or exchanges may be reshipped to you following payment of an inspection/shipping fee.
- Returned items will be subject to a 7.5% restocking fee. A returned item is an item that is being sent back for a refund.
- If you refuse delivery of your order for any reason, you will be refunded the cost of your order less shipping fees.
- All partial or full refunds will be posted to the credit card used for purchase.
- Hyperice is not responsible for items lost or damaged during shipping.
NormaTec Industries, LP
480 Pleasant Street, Suite A200
Watertown, Massachusetts 02472 USA